{"title":"Tight Buffer Fiber Optic Cable","description":"\u003cp\u003e\u003cbr\u003e\u003cbr\u003e\u003c\/p\u003e","products":[{"product_id":"distribution-fiber-optic-cable-2-strand-multimode-62-5125-om1-indooroutdoor-riser","title":"Tight Buffer Distribution Riser Fiber Optic Cable, Multimode OM1, Indoor\/Outdoor","description":"\u003cp\u003e\u003cimg height=\"65px\" width=\"115px\" class=\"bulleticons\" alt=\"Made in USA\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0252\/1897\/3741\/files\/Made_In_USA.png?2208\"\u003e \u003cimg height=\"65px\" width=\"76px\" class=\"bulleticons\" alt=\"UL Listed\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0252\/1897\/3741\/files\/UL_LISTED_LOGO_US.png?2209\"\u003e\u003c\/p\u003e\n\u003ch5\u003eWe do not offer credits or returns for this item.\u003c\/h5\u003e\n\u003ch3\u003eThis fiber cable is priced per foot and may include a minimum order length.\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eIf you would like to inquire about our custom fiber cable options such as terminated ends, pulleyes, and custom cut lengths, please call or email us.\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch4\u003eDescription\u003c\/h4\u003e\n\u003ch2\u003eTight Buffer Fiber Optic Cable, Multi-Mode, OM1 62.5\/125, Distribution Cable, OFNR Riser Rated, Indoor\/Outdoor, Black Outer Jacket\u003c\/h2\u003e\n\u003cp\u003eThis riser distribution fiber cable is ideal for Indoor\/outdoor applications. The tight-bound, tight-buffered design allows the fiber cables to be installed in intra-building backbone and inter-building campus locations without costly transitions between cable types. It's ideal for configurations requiring a single termination point with multiple fibers. The riser distribution fiber cable uses high performance components and construction and is UL Listed in accordance with NEC sections 770.179(b) for use in vertical runs in building riser shafts or from floor to floor.\u003c\/p\u003e\n\u003ch3\u003eMulti-Mode Fiber Information\u003c\/h3\u003e\n\u003cp\u003eMulti-Mode cable commonly has a diameter in the 50-to-100 micron range (typical multimode fiber core diameters are 50 or 62.5 micrometers). Multimode fiber gives you high bandwidth at high speeds (10 to 100MBS - Gigabit to 275m to 2km) over medium distances. Light waves are dispersed into numerous paths, or modes, as they travel through the cable's core typically 850 or 1300nm. However, in long cable runs (greater than 3000 feet [914.4 meters), multiple paths of light can cause signal distortion at the receiving end, resulting in an unclear and incomplete data transmission so designers now call for single mode fiber in new applications using Gigabit and beyond.\u003c\/p\u003e\n\u003ch3\u003eApplications:\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eIndoor\/outdoor tight-bound tight-buffered design allows cables to be installed in intra-building backbone and inter-building campus locations without costly transitions between cable types\u003c\/li\u003e\n\u003cli\u003eIdeal configuration for a single termination point requiring multiple fibers\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCost Savings\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e900 micron buffer eliminates the need for costly and time-consuming installation of fanout kits or pigtail splices because connectors terminate directly to the fiber\u003c\/li\u003e\n\u003cli\u003eNo need to splice outdoor cable to indoor cable at building entrance\u003c\/li\u003e\n\u003cli\u003eHigh crush resistance may eliminate the need for innerduct\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan data-mce-fragment=\"1\"\u003eCleaning your fiber connector end faces and components regularly is crucial for avoiding a total network failure. Ensure your optical fiber system is working properly and prevent major network issues with \u003c\/span\u003e\u003ca data-mce-fragment=\"1\" alt=\"Fiber Cleaning Kits\" href=\"https:\/\/www.primuscable.com\/collections\/fiber-cleaning-kit\" target=\"_blank\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003efiber cleaning kits,\u003c\/strong\u003e\u003c\/a\u003e\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003ca data-mce-fragment=\"1\" alt=\"Fiber Cleaning Pens\" href=\"https:\/\/www.primuscable.com\/collections\/fiber-cleaning-pens\" target=\"_blank\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003epens,\u003c\/strong\u003e\u003c\/a\u003e\u003ca data-mce-fragment=\"1\" alt=\"Fiber Cleaning Fluids\" href=\"https:\/\/www.primuscable.com\/collections\/fiber-cleaning-fluids\" target=\"_blank\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003efluids,\u003c\/strong\u003e\u003c\/a\u003e\u003cspan data-mce-fragment=\"1\"\u003e and \u003c\/span\u003e\u003ca data-mce-fragment=\"1\" alt=\"Fiber Cleaning Wipes\" href=\"https:\/\/www.primuscable.com\/collections\/fiber-cleaning-wipes\" target=\"_blank\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003ewipes.\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003ch4\u003eFeatures\u003c\/h4\u003e\n\u003ch3\u003e\u003cspan style=\"text-decoration: underline;\"\u003eFeatures\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eHigh performance components and construction\u003c\/li\u003e\n\u003cli\u003eCable materials are indoor\/outdoor - UL-listed OFNR and UV, water and fungus resistant\u003c\/li\u003e\n\u003cli\u003eUL Listed in accordance with NEC section 770.179(b) for use in vertical runs in building riser shafts or from floor to floor\u003c\/li\u003e\n\u003cli\u003eWide operating temperature range of -40ºC to +85ºC\u003c\/li\u003e\n\u003cli\u003eHelically stranded core for greater flexibility and mechanical protection of the optical fibers\u003c\/li\u003e\n\u003cli\u003eHigh strength-to-weight ratio\u003c\/li\u003e\n\u003cli\u003e2-144 fiber configuration is smaller and lighter than comparable sub-grouped cables made by others: ideal for installation in areas with limited space or tight bends\u003c\/li\u003e\n\u003cli\u003eCan be armored for additional protection in direct burial and aerial installations\u003c\/li\u003e\n\u003cli\u003eInterlocking armor can be applied to cables as an alternative to conduit installation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eSpecifications\u003c\/h4\u003e\n\u003ch3\u003eCharacteristics\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eOperating Temp: -40°C to +85°C\u003c\/li\u003e\n\u003cli\u003eStorage Temp: -55°C to +85°C\u003c\/li\u003e\n\u003cli\u003eInstall Temp: -10°C to +60°C\u003c\/li\u003e\n\u003cli\u003eFlame Retardancy: UL Listed Type OFNR (UL 1666)\u003c\/li\u003e\n\u003cli\u003eCrush Resist: 1800 N\/cm\u003c\/li\u003e\n\u003cli\u003eImpact Resist: 1500 impacts\u003c\/li\u003e\n\u003cli\u003eFlex Resist: 2000 cycles\u003c\/li\u003e\n\u003cli\u003eJacket Type: D\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eStandards\u003c\/h3\u003e\n\u003cp\u003eOptical Cable Corporation's Indoor\/Outdoor tight-buffered fiber optic cables meet the functional requirements of the following standards:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eUL 1651\u003c\/li\u003e\n\u003cli\u003eUL 1666\u003c\/li\u003e\n\u003cli\u003eGR-409-CORE\u003c\/li\u003e\n\u003cli\u003eICEA-S-104-696\u003c\/li\u003e\n\u003cli\u003eICEA-S-83-596\u003c\/li\u003e\n\u003cli\u003eTIA-568\u003c\/li\u003e\n\u003cli\u003eTIA-598\u003c\/li\u003e\n\u003cli\u003eUL-listed type OFNR in accordance with NEC sections 770-179 (B) and 770-154 (B) for use in vertical runs in building riser shafts or from floor to floor. Meets or exceeds requirements for intra-building fiber optic cables as outlined in GR-409-CORE.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0079\/8874\/0186\/files\/OCC-DX-Riser-Specs.pdf?1515\" target=\"_blank\"\u003e \u003cbutton class=\"download-btn\"\u003eFiber Specifications Chart\u003c\/button\u003e \u003c\/a\u003e\u003c\/p\u003e\n\u003ch4\u003eFiber Performance\u003c\/h4\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0079\/8874\/0186\/files\/OCC-Ultra-Fox-perf_chart-1.pdf?1510\" target=\"_blank\"\u003e \u003cbutton class=\"download-btn\"\u003eFiber Performance Chart\u003c\/button\u003e \u003c\/a\u003e\u003c\/p\u003e","brand":"OCC","offers":[{"title":"2 Strand","offer_id":31710065459261,"sku":"DX002DWLS9KR","price":0.39,"currency_code":"USD","in_stock":true},{"title":"6 Strand","offer_id":31710065492029,"sku":"DX006DWLS9KR","price":0.82,"currency_code":"USD","in_stock":true},{"title":"12 Strand","offer_id":31710065524797,"sku":"DX012DWLS9KR","price":1.56,"currency_code":"USD","in_stock":true},{"title":"24 Strand","offer_id":31710065557565,"sku":"DX024DWLS9KR","price":3.3,"currency_code":"USD","in_stock":true},{"title":"48 Strand","offer_id":31710065590333,"sku":"DX048DWLS9KR","price":6.73,"currency_code":"USD","in_stock":true},{"title":"72 Strand","offer_id":31710065623101,"sku":"DX072DWLS9KR","price":10.04,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0252\/1897\/3741\/products\/MMR-2STRAND.png?v=1567190604"},{"product_id":"distribution-fiber-optic-cable-2-strand-multimode-10-gig-om3-indoor-outdoor-riser","title":"Tight Buffer Distribution Riser Fiber Optic Cable, Multimode 10 Gig OM3, Indoor\/Outdoor","description":"\u003cp\u003e\u003cimg height=\"65px\" width=\"115px\" class=\"bulleticons\" alt=\"Made in USA\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0252\/1897\/3741\/files\/Made_In_USA.png?2208\"\u003e \u003cimg height=\"65px\" width=\"76px\" class=\"bulleticons\" alt=\"UL Listed\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0252\/1897\/3741\/files\/UL_LISTED_LOGO_US.png?2209\"\u003e\u003c\/p\u003e\n\u003ch3\u003eWe do not offer credits or returns for this item.\u003c\/h3\u003e\n\u003ch3\u003eThis fiber cable is priced per foot and may include a minimum order length.\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eIf you would like to inquire about our custom fiber cable options such as terminated ends, pulleyes, and custom cut lengths, please call or email us.\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch4\u003eDescription\u003c\/h4\u003e\n\u003ch2\u003eTight Buffer Fiber Optic Cable, Multi-Mode, OM3 50\/125, Distribution Cable, OFNR Riser Rated, Indoor\/Outdoor, Black Outer Jacket\u003c\/h2\u003e\n\u003cp\u003eThis riser distribution fiber cable is ideal for Indoor\/outdoor applications. The tight-bound, tight-buffered design allows the fiber cables to be installed in intra-building backbone and inter-building campus locations without costly transitions between cable types. It's ideal for configurations requiring a single termination point with multiple fibers. The riser distribution fiber cable uses high performance components and construction and is UL Listed in accordance with NEC sections 770.179(b) for use in vertical runs in building riser shafts or from floor to floor.\u003c\/p\u003e\n\u003ch3\u003eMulti-Mode Fiber Information\u003c\/h3\u003e\n\u003cp\u003eMulti-Mode cable commonly has a diameter in the 50-to-100 micron range (typical multimode fiber core diameters are 50 or 62.5 micrometers). Multimode fiber gives you high bandwidth at high speeds (10 to 100MBS - Gigabit to 275m to 2km) over medium distances. Light waves are dispersed into numerous paths, or modes, as they travel through the cable's core typically 850 or 1300nm. However, in long cable runs (greater than 3000 feet [914.4 meters), multiple paths of light can cause signal distortion at the receiving end, resulting in an unclear and incomplete data transmission so designers now call for single mode fiber in new applications using Gigabit and beyond.\u003c\/p\u003e\n\u003ch3\u003eApplications:\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eIndoor\/outdoor tight-bound tight-buffered design allows cables to be installed in intra-building backbone and inter-building campus locations without costly transitions between cable types\u003c\/li\u003e\n\u003cli\u003eIdeal configuration for a single termination point requiring multiple fibers\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCost Savings\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e900 micron buffer eliminates the need for costly and time-consuming installation of fanout kits or pigtail splices because connectors terminate directly to the fiber\u003c\/li\u003e\n\u003cli\u003eNo need to splice outdoor cable to indoor cable at building entrance\u003c\/li\u003e\n\u003cli\u003eHigh crush resistance may eliminate the need for innerduct\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan data-mce-fragment=\"1\"\u003eCleaning your fiber connector end faces and components regularly is crucial for avoiding a total network failure. Ensure your optical fiber system is working properly and prevent major network issues with \u003c\/span\u003e\u003ca data-mce-fragment=\"1\" alt=\"Fiber Cleaning Kits\" href=\"https:\/\/www.primuscable.com\/collections\/fiber-cleaning-kit\" target=\"_blank\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003efiber cleaning kits,\u003c\/strong\u003e\u003c\/a\u003e\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003ca data-mce-fragment=\"1\" alt=\"Fiber Cleaning Pens\" href=\"https:\/\/www.primuscable.com\/collections\/fiber-cleaning-pens\" target=\"_blank\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003epens,\u003c\/strong\u003e\u003c\/a\u003e\u003ca data-mce-fragment=\"1\" alt=\"Fiber Cleaning Fluids\" href=\"https:\/\/www.primuscable.com\/collections\/fiber-cleaning-fluids\" target=\"_blank\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003efluids,\u003c\/strong\u003e\u003c\/a\u003e\u003cspan data-mce-fragment=\"1\"\u003e and \u003c\/span\u003e\u003ca data-mce-fragment=\"1\" alt=\"Fiber Cleaning Wipes\" href=\"https:\/\/www.primuscable.com\/collections\/fiber-cleaning-wipes\" target=\"_blank\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003ewipes.\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003ch4\u003eFeatures\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eHigh performance components and construction\u003c\/li\u003e\n\u003cli\u003eCable materials are indoor\/outdoor - UL-listed OFNR and UV, water and fungus resistant\u003c\/li\u003e\n\u003cli\u003eUL Listed in accordance with NEC section 770.179(b) for use in vertical runs in building riser shafts or from floor to floor\u003c\/li\u003e\n\u003cli\u003eWide operating temperature range of -40ºC to +85ºC\u003c\/li\u003e\n\u003cli\u003eHelically stranded core for greater flexibility and mechanical protection of the optical fibers\u003c\/li\u003e\n\u003cli\u003eHigh strength-to-weight ratio\u003c\/li\u003e\n\u003cli\u003e2-144 fiber configuration is smaller and lighter than comparable sub-grouped cables made by others: ideal for installation in areas with limited space or tight bends\u003c\/li\u003e\n\u003cli\u003eCan be armored for additional protection in direct burial and aerial installations\u003c\/li\u003e\n\u003cli\u003eInterlocking armor can be applied to cables as an alternative to conduit installation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eSpecifications\u003c\/h4\u003e\n\u003ch3\u003eCharacteristics\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eOperating Temp: -40°C to +85°C\u003c\/li\u003e\n\u003cli\u003eStorage Temp: -55°C to +85°C\u003c\/li\u003e\n\u003cli\u003eInstall Temp: -10°C to +60°C\u003c\/li\u003e\n\u003cli\u003eFlame Retardancy: UL Listed Type OFNR (UL 1666)\u003c\/li\u003e\n\u003cli\u003eCrush Resist: 1800 N\/cm\u003c\/li\u003e\n\u003cli\u003eImpact Resist: 1500 impacts\u003c\/li\u003e\n\u003cli\u003eFlex Resist: 2000 cycles\u003c\/li\u003e\n\u003cli\u003eJacket Type: D\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eStandards\u003c\/h3\u003e\n\u003cp\u003eOptical Cable Corporation's Indoor\/Outdoor tight-buffered fiber optic cables meet the functional requirements of the following standards:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eUL 1651\u003c\/li\u003e\n\u003cli\u003eUL 1666\u003c\/li\u003e\n\u003cli\u003eGR-409-CORE\u003c\/li\u003e\n\u003cli\u003eICEA-S-104-696\u003c\/li\u003e\n\u003cli\u003eICEA-S-83-596\u003c\/li\u003e\n\u003cli\u003eTIA-568\u003c\/li\u003e\n\u003cli\u003eTIA-598\u003c\/li\u003e\n\u003cli\u003eUL-listed type OFNR in accordance with NEC sections 770-179 (B) and 770-154 (B) for use in vertical runs in building riser shafts or from floor to floor. Meets or exceeds requirements for intra-building fiber optic cables as outlined in GR-409-CORE.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0079\/8874\/0186\/files\/OCC-DX-Riser-Specs.pdf?1515\" target=\"_blank\"\u003e \u003cbutton class=\"download-btn\"\u003eFiber Specifications Chart\u003c\/button\u003e \u003c\/a\u003e\u003c\/p\u003e\n\u003ch4\u003eFiber Performance\u003c\/h4\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0079\/8874\/0186\/files\/OCC-Ultra-Fox-perf_chart-1.pdf?1510\" target=\"_blank\"\u003e \u003cbutton class=\"download-btn\"\u003eFiber Performance Chart\u003c\/button\u003e \u003c\/a\u003e\u003c\/p\u003e","brand":"OCC","offers":[{"title":"2 Strand","offer_id":31706241302589,"sku":"DX002DALT9QR","price":1.35,"currency_code":"USD","in_stock":true},{"title":"6 Strand","offer_id":31706241368125,"sku":"DX006DALT9QR","price":1.02,"currency_code":"USD","in_stock":true},{"title":"12 Strand","offer_id":31706241400893,"sku":"DX012DALT9QR","price":1.9,"currency_code":"USD","in_stock":true},{"title":"24 Strand","offer_id":31706241433661,"sku":"DX024DALT9QR","price":4.79,"currency_code":"USD","in_stock":true},{"title":"48 Strand","offer_id":31706241466429,"sku":"DX048DALT9QR","price":14.02,"currency_code":"USD","in_stock":true},{"title":"72 Strand","offer_id":31706241499197,"sku":"DX072DALT9QR","price":20.64,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0252\/1897\/3741\/products\/blue2_L.jpg?v=1567190615"},{"product_id":"distribution-fiber-optic-cable-2-strand-single-mode-9125-indooroutdoor-riser","title":"Tight Buffer Distribution Riser Fiber Optic Cable, Single Mode, Indoor\/Outdoor","description":"\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0252\/1897\/3741\/files\/Made_In_USA.png?2208\" alt=\"Made in USA\" class=\"bulleticons\" width=\"115px\" height=\"65px\"\u003e \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0252\/1897\/3741\/files\/UL_LISTED_LOGO_US.png?2209\" alt=\"UL Listed\" class=\"bulleticons\" width=\"76px\" height=\"65px\"\u003e \u003cmeta charset=\"utf-8\"\u003e\n\u003ch3\u003e(We do not offer credits or returns for this item.)\u003c\/h3\u003e\n\u003ch3\u003eThis fiber cable is priced per foot and may include a minimum order length.\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eIf you would like to inquire about our custom fiber cable options such as terminated ends, pulleyes, and custom cut lengths, please call or email us.\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch4\u003eDescription\u003c\/h4\u003e\n\u003ch2\u003eBulk Fiber, Single Mode, OS2 9\/125, Distribution Cable, OFNR Riser Rated, Indoor\/Outdoor, Tight Buffer, Black Outer Jacket\u003c\/h2\u003e\n\u003cp\u003eThis riser distribution fiber cable is ideal for Indoor\/outdoor applications. The tight-bound, tight-buffered design allows the fiber cables to be installed in intra-building backbone and inter-building campus locations without costly transitions between cable types. It's ideal for configurations requiring a single termination point with multiple fibers. The riser distribution fiber cable uses high performance components and construction and is UL Listed in accordance with NEC sections 770.179(b) for use in vertical runs in building riser shafts or from floor to floor.\u003c\/p\u003e\n\u003c!--\u003ch3\u003eMulti-Mode Fiber Information\u003c\/h3\u003e\n\u003cp\u003eMulti-Mode cable commonly has a diameter in the 50-to-100 micron range (typical multimode fiber core diameters are 50 or 62.5 micrometers). Multimode fiber gives you high bandwidth at high speeds (10 to 100MBS - Gigabit to 275m to 2km) over medium distances. Light waves are dispersed into numerous paths, or modes, as they travel through the cable's core typically 850 or 1300nm. However, in long cable runs (greater than 3000 feet [914.4 meters), multiple paths of light can cause signal distortion at the receiving end, resulting in an unclear and incomplete data transmission so designers now call for single mode fiber in new applications using Gigabit and beyond.\u003c\/p\u003e--\u003e\n\u003ch3\u003eSingle Mode Fiber Information\u003c\/h3\u003e\n\u003cp\u003eSingle mode fiber cable (Synonyms mono-mode optical fiber, single-mode fiber, single-mode optical waveguide, uni-mode fiber) is a single strand of glass fiber with a diameter of 8.3 to 10 microns that has one mode of transmission. Single mode fiber has a relatively narrow diameter, through which only one mode will propagate typically 1310 or 1550nm wavelengths. Single mode fibers carry higher bandwidth than multimode fiber, but require a light source with a narrow spectral width. Single-mode fiber gives you a higher transmission rate and up to 50 times more distance than multimode. The small core and single light-wave virtually eliminate any distortion that could result from overlapping light pulses, providing the least signal attenuation and the highest transmission speeds of any fiber cable type.\u003c\/p\u003e\n\u003ch3\u003eApplications:\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eIndoor\/outdoor tight-bound tight-buffered design allows cables to be installed in intra-building backbone and inter-building campus locations without costly transitions between cable types\u003c\/li\u003e\n\u003cli\u003eIdeal configuration for a single termination point requiring multiple fibers\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCost Savings\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e900 micron buffer eliminates the need for costly and time-consuming installation of fanout kits or pigtail splices because connectors terminate directly to the fiber\u003c\/li\u003e\n\u003cli\u003eNo need to splice outdoor cable to indoor cable at building entrance\u003c\/li\u003e\n\u003cli\u003eHigh crush resistance may eliminate the need for innerduct\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan data-mce-fragment=\"1\"\u003eCleaning your fiber connector end faces and components regularly is crucial for avoiding a total network failure. Ensure your optical fiber system is working properly and prevent major network issues with \u003c\/span\u003e\u003ca href=\"https:\/\/www.primuscable.com\/collections\/fiber-cleaning-kit\" alt=\"Fiber Cleaning Kits\" data-mce-fragment=\"1\" data-mce-href=\"https:\/\/www.primuscable.com\/collections\/fiber-cleaning-kit\" target=\"_blank\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003efiber cleaning kits,\u003c\/strong\u003e\u003c\/a\u003e\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003ca href=\"https:\/\/www.primuscable.com\/collections\/fiber-cleaning-pens\" alt=\"Fiber Cleaning Pens\" data-mce-fragment=\"1\" data-mce-href=\"https:\/\/www.primuscable.com\/collections\/fiber-cleaning-pens\" target=\"_blank\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003epens,\u003c\/strong\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/www.primuscable.com\/collections\/fiber-cleaning-fluids\" alt=\"Fiber Cleaning Fluids\" data-mce-fragment=\"1\" data-mce-href=\"https:\/\/www.primuscable.com\/collections\/fiber-cleaning-fluids\" target=\"_blank\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003efluids,\u003c\/strong\u003e\u003c\/a\u003e\u003cspan data-mce-fragment=\"1\"\u003e and \u003c\/span\u003e\u003ca href=\"https:\/\/www.primuscable.com\/collections\/fiber-cleaning-wipes\" alt=\"Fiber Cleaning Wipes\" data-mce-fragment=\"1\" data-mce-href=\"https:\/\/www.primuscable.com\/collections\/fiber-cleaning-wipes\" target=\"_blank\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003ewipes.\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003ch4\u003eFeatures\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eHigh performance components and construction\u003c\/li\u003e\n\u003cli\u003eCable materials are indoor\/outdoor - UL-listed OFNR and UV, water and fungus resistant\u003c\/li\u003e\n\u003cli\u003eUL Listed in accordance with NEC section 770.179(b) for use in vertical runs in building riser shafts or from floor to floor\u003c\/li\u003e\n\u003cli\u003eWide operating temperature range of -40ºC to +85ºC\u003c\/li\u003e\n\u003cli\u003eHelically stranded core for greater flexibility and mechanical protection of the optical fibers\u003c\/li\u003e\n\u003cli\u003eHigh strength-to-weight ratio\u003c\/li\u003e\n\u003cli\u003e2-144 fiber configuration is smaller and lighter than comparable sub-grouped cables made by others: ideal for installation in areas with limited space or tight bends\u003c\/li\u003e\n\u003cli\u003eCan be armored for additional protection in direct burial and aerial installations\u003c\/li\u003e\n\u003cli\u003eInterlocking armor can be applied to cables as an alternative to conduit installation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eSpecifications\u003c\/h4\u003e\n\u003ch3\u003eCharacteristics\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eOperating Temp: -40°C to +85°C\u003c\/li\u003e\n\u003cli\u003eStorage Temp: -55°C to +85°C\u003c\/li\u003e\n\u003cli\u003eInstall Temp: -10°C to +60°C\u003c\/li\u003e\n\u003cli\u003eFlame Retardancy: UL Listed Type OFNR (UL 1666)\u003c\/li\u003e\n\u003cli\u003eCrush Resist: 1800 N\/cm\u003c\/li\u003e\n\u003cli\u003eImpact Resist: 1500 impacts\u003c\/li\u003e\n\u003cli\u003eFlex Resist: 2000 cycles\u003c\/li\u003e\n\u003cli\u003eJacket Type: D\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eStandards\u003c\/h3\u003e\n\u003cp\u003eOptical Cable Corporation's Indoor\/Outdoor tight-buffered fiber optic cables meet the functional requirements of the following standards:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eUL 1651\u003c\/li\u003e\n\u003cli\u003eUL 1666\u003c\/li\u003e\n\u003cli\u003eGR-409-CORE\u003c\/li\u003e\n\u003cli\u003eICEA-S-104-696\u003c\/li\u003e\n\u003cli\u003eICEA-S-83-596\u003c\/li\u003e\n\u003cli\u003eTIA-568\u003c\/li\u003e\n\u003cli\u003eTIA-598\u003c\/li\u003e\n\u003cli\u003eUL-listed type OFNR in accordance with NEC sections 770-179 (B) and 770-154 (B) for use in vertical runs in building riser shafts or from floor to floor. Meets or exceeds requirements for intra-building fiber optic cables as outlined in GR-409-CORE.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003e\n   \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0079\/8874\/0186\/files\/OCC-DX-Riser-Specs.pdf?1515\" target=\"_blank\"\u003e\n      \u003cbutton class=\"download-btn\"\u003eFiber Specifications Chart\u003c\/button\u003e\n   \u003c\/a\u003e\n\u003c\/p\u003e\n\n\u003ch4\u003eFiber Performance\u003c\/h4\u003e\n\n\u003cp\u003e\n   \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0079\/8874\/0186\/files\/OCC-Ultra-Fox-perf_chart-1.pdf?1510\" target=\"_blank\"\u003e\n      \u003cbutton class=\"download-btn\"\u003eFiber Performance Chart\u003c\/button\u003e\n   \u003c\/a\u003e\n\u003c\/p\u003e","brand":"OCC","offers":[{"title":"2 Strand","offer_id":31710243717181,"sku":"DX002DSLX9KR","price":0.38,"currency_code":"USD","in_stock":true},{"title":"6 Strand","offer_id":31710243749949,"sku":"DX006DSLX9KR","price":0.5,"currency_code":"USD","in_stock":true},{"title":"12 Strand","offer_id":31710243782717,"sku":"DX012DSLX9KR","price":0.86,"currency_code":"USD","in_stock":true},{"title":"24 Strand","offer_id":31710243815485,"sku":"DX024DSLX9KR","price":1.7,"currency_code":"USD","in_stock":true},{"title":"48 Strand","offer_id":31710243848253,"sku":"DX048DSLA9KR","price":4.6,"currency_code":"USD","in_stock":true},{"title":"72 Strand","offer_id":31710243881021,"sku":"DX072DSLX9KR","price":4.35,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0252\/1897\/3741\/products\/DX002DSLX9KR_L.jpg?v=1567190617"},{"product_id":"distribution-fiber-optic-cable-2-strand-multimode-62-5125-om1-indooroutdoor-plenum","title":"Tight Buffer Distribution Plenum Fiber Optic Cable, Multimode, OM1, Indoor\/Outdoor","description":"\u003cp\u003e\u003cimg height=\"65px\" width=\"115px\" class=\"bulleticons\" alt=\"Made in USA\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0252\/1897\/3741\/files\/Made_In_USA.png?2208\"\u003e \u003cimg height=\"65px\" width=\"76px\" class=\"bulleticons\" alt=\"UL Listed\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0252\/1897\/3741\/files\/UL_LISTED_LOGO_US.png?2209\"\u003e \u003cmeta charset=\"utf-8\"\u003e\u003c\/p\u003e\n\u003ch3\u003e(We do not offer credits or returns for this item.)\u003c\/h3\u003e\n\u003ch3\u003eThis fiber cable is priced per foot and may include a minimum order length.\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eIf you would like to inquire about our custom fiber cable options such as terminated ends, pulleyes, and custom cut lengths, please call or email us.\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch4\u003eDescription\u003c\/h4\u003e\n\u003ch2\u003eOCC's OM1 Indoor\/Outdoor Plenum Distribution Cable\u003c\/h2\u003e\n\u003cp\u003eThis plenum distribution fiber cable is used in trunking, LAN and distribution applications where small size, lightweight, and versatile installation capability are required for ducts, plenums, and air handling spaces. It's ideal for configurations requiring a single termination point with multiple fibers. The plenum distribution fiber optic cable uses high performance components and construction and is UL Listed in accordance with NEC section 770.179(a) for use in ducts, plenums and air-handling spaces.\u003c\/p\u003e\n\u003ch3\u003eMultimode Fiber Information\u003c\/h3\u003e\n\u003cp\u003eMulti-Mode cable commonly has a diameter in the 50-to-100 micron range (typical multimode fiber core diameters are 50 or 62.5 micrometers). Multimode fiber gives you high bandwidth at high speeds (10 to 100MBS - Gigabit to 275m to 2km) over medium distances. Light waves are dispersed into numerous paths, or modes, as they travel through the cable's core typically 850 or 1300nm. However, in long cable runs (greater than 3000 feet [914.4 meters), multiple paths of light can cause signal distortion at the receiving end, resulting in an unclear and incomplete data transmission so designers now call for single mode fiber in new applications using Gigabit and beyond.\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eCleaning your fiber connector end faces and components regularly is crucial for avoiding a total network failure. Ensure your optical fiber system is working properly and prevent major network issues with \u003c\/span\u003e\u003ca alt=\"Fiber Cleaning Kits\" href=\"https:\/\/www.primuscable.com\/collections\/fiber-cleaning-kit\" target=\"_blank\"\u003e\u003cstrong\u003efiber cleaning kits,\u003c\/strong\u003e\u003c\/a\u003e\u003cspan\u003e \u003c\/span\u003e\u003ca alt=\"Fiber Cleaning Pens\" href=\"https:\/\/www.primuscable.com\/collections\/fiber-cleaning-pens\" target=\"_blank\"\u003e\u003cstrong\u003epens,\u003c\/strong\u003e\u003c\/a\u003e\u003ca alt=\"Fiber Cleaning Fluids\" href=\"https:\/\/www.primuscable.com\/collections\/fiber-cleaning-fluids\" target=\"_blank\"\u003e\u003cstrong\u003e\u003cspan\u003e \u003c\/span\u003efluids,\u003c\/strong\u003e\u003c\/a\u003e\u003cspan\u003e and \u003c\/span\u003e\u003ca alt=\"Fiber Cleaning Wipes\" href=\"https:\/\/www.primuscable.com\/collections\/fiber-cleaning-wipes\" target=\"_blank\"\u003e\u003cstrong\u003ewipes.\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003ch4\u003eFeatures\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eHigh performance components and construction\u003c\/li\u003e\n\u003cli\u003eHigh specific strength-to-weight ratio and compact cable design for limited conduit space and tight bends in long cable pulls\u003c\/li\u003e\n\u003cli\u003eHelically stranded core for flexibility, survival in difficult installations, and mechanical protection for the fibers\u003c\/li\u003e\n\u003cli\u003eLower installed cost\u003c\/li\u003e\n\u003cli\u003eHigh performance tight-buffered coating on each fiber for environmental and mechanical protection\u003c\/li\u003e\n\u003cli\u003eHigh crush resistance may eliminate the need for innerduct\u003c\/li\u003e\n\u003cli\u003e900 μm buffer eliminates the need for costly and time-consuming installation of fanout kits or pigtail splices because connectors terminate directly to the fiber.\u003c\/li\u003e\n\u003cli\u003eUL Listed in accordance with NEC section 770.179(a) for use in ducts, plenums and air-handling spaces\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eUsed in trunking, LAN and distribution applications where small size, lightweight, and versatile installation capability are required for ducts, plenums, and air handling spaces\u003c\/li\u003e\n\u003cli\u003eIdeal configuration for a single termination point requiring multiple fibers\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eIndoor\/Outdoor (\"K\" Fluoropolymer Plenum Jacket)\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eIndoor\/Outdoor plenum cables eliminate the need for costly cable transitions in different installation environments\u003c\/li\u003e\n\u003cli\u003eCable materials are UV, water and fungus resistant\u003c\/li\u003e\n\u003cli\u003eHigher fiber counts available than similar cables available by others in subgrouped configuration\u003c\/li\u003e\n\u003cli\u003eJacket is highly chemical resistant for installation in harsh industrial environments\u003c\/li\u003e\n\u003cli\u003eInterlocking armor can be applied to cables as an alternative to conduit installation\u003c\/li\u003e\n\u003cli\u003eCan be installed outside and in plenum or riser pathways inside, eliminating the need to transition cable types between environments\u003c\/li\u003e\n\u003cli\u003e2 to 72 fiber configuration is smaller and lighter than comparable sub-grouped cables, which is ideal for installation in areas with limited space or tight bends\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eStandards List\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eUL 1651\u003c\/li\u003e\n\u003cli\u003eANSI\/NFPA 262\u003c\/li\u003e\n\u003cli\u003eGR-409-CORE\u003c\/li\u003e\n\u003cli\u003eICEA-S-104-696\u003c\/li\u003e\n\u003cli\u003eICEA-S-83-596\u003c\/li\u003e\n\u003cli\u003eTIA-568\u003c\/li\u003e\n\u003cli\u003eTIA-598\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eSpecifications\u003c\/h4\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0079\/8874\/0186\/files\/OCC-DX-In-Out-Plenum.pdf?1491\" target=\"_blank\"\u003e \u003cbutton class=\"download-btn\"\u003eSpec Sheet\u003c\/button\u003e \u003c\/a\u003e\u003c\/p\u003e","brand":"OCC","offers":[{"title":"2 Strand","offer_id":31706601193533,"sku":"DX002KWLS9OP","price":1.88,"currency_code":"USD","in_stock":true},{"title":"6 Strand","offer_id":31706601226301,"sku":"DX006KWLS9OP","price":1.34,"currency_code":"USD","in_stock":true},{"title":"12 Strand","offer_id":31706601259069,"sku":"DX012KWLS9OP","price":1.93,"currency_code":"USD","in_stock":true},{"title":"24 Strand","offer_id":31706601324605,"sku":"DX024KWLS9OP","price":3.98,"currency_code":"USD","in_stock":true},{"title":"48 Strand","offer_id":31706601357373,"sku":"DX048KWLS9OP","price":7.48,"currency_code":"USD","in_stock":true},{"title":"72 Strand","offer_id":31706601390141,"sku":"DX072KWLS9OP","price":10.42,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0252\/1897\/3741\/products\/DX002Sxxx9OP_L_54dfb73c-d7c4-4e29-afbd-2fcc98c61a60.jpg?v=1567190617"},{"product_id":"distribution-fiber-optic-cable-2-strand-multimode-10-gig-om3-indoor-outdoor-plenum","title":"Indoor\/Outdoor Multimode 10 Gig OM3 Tight Buffer Distribution Plenum Fiber Optic Cable","description":"\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0252\/1897\/3741\/files\/Made_In_USA.png?2208\" alt=\"Made in USA\" class=\"bulleticons\" width=\"115px\" height=\"65px\"\u003e \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0252\/1897\/3741\/files\/UL_LISTED_LOGO_US.png?2209\" alt=\"UL Listed\" class=\"bulleticons\" width=\"76px\" height=\"65px\"\u003e \u003cmeta charset=\"utf-8\"\u003e\u003c\/p\u003e\n\u003ch3\u003e(We do not offer credits or returns for this item.)\u003c\/h3\u003e\n\u003ch3\u003eThis fiber cable is priced per foot and may include a minimum order length.\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eIf you would like to inquire about our custom fiber cable options such as terminated ends, pulleyes, and custom cut lengths, please call or email us.\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch4\u003eDescription\u003c\/h4\u003e\n\u003ch2\u003eOCC's Tight Buffer Distribution Plenum Fiber Optic Cable, Multimode, 10 Gig OM3, Indoor\/Outdoor\u003c\/h2\u003e\n\u003cp\u003e\u003cmeta charset=\"utf-8\"\u003e\u003cspan\u003eThis plenum distribution fiber cable is perfect for trunking, LAN, and distribution applications, offering small size, lightweight build, and versatile installation in ducts, plenums, and air handling spaces. It's optimal for setups needing a single termination point with multiple fibers, utilizing high-performance components and UL Listing (NEC section 770.179(a)) for ducts, plenums, and air-handling spaces.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eMultimode Fiber Information\u003c\/h3\u003e\n\u003cp\u003eMulti-Mode cable commonly has a diameter in the 50-to-100 micron range (typical multimode fiber core diameters are 50 or 62.5 micrometers). Multimode fiber gives you high bandwidth at high speeds (10 to 100MBS - Gigabit to 275m to 2km) over medium distances. Light waves are dispersed into numerous paths, or modes, as they travel through the cable's core typically 850 or 1300nm. However, in long cable runs (greater than 3000 feet [914.4 meters), multiple paths of light can cause signal distortion at the receiving end, resulting in an unclear and incomplete data transmission so designers now call for single mode fiber in new applications using Gigabit and beyond.\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eCleaning your fiber connector end faces and components regularly is crucial for avoiding a total network failure. Ensure your optical fiber system is working properly and prevent major network issues with \u003c\/span\u003e\u003ca href=\"https:\/\/www.primuscable.com\/collections\/fiber-cleaning-kit\" alt=\"Fiber Cleaning Kits\" target=\"_blank\"\u003e\u003cstrong\u003efiber cleaning kits,\u003c\/strong\u003e\u003c\/a\u003e\u003cspan\u003e \u003c\/span\u003e\u003ca href=\"https:\/\/www.primuscable.com\/collections\/fiber-cleaning-pens\" alt=\"Fiber Cleaning Pens\" target=\"_blank\"\u003e\u003cstrong\u003epens,\u003c\/strong\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/www.primuscable.com\/collections\/fiber-cleaning-fluids\" alt=\"Fiber Cleaning Fluids\" target=\"_blank\"\u003e\u003cstrong\u003e\u003cspan\u003e \u003c\/span\u003efluids,\u003c\/strong\u003e\u003c\/a\u003e\u003cspan\u003e and \u003c\/span\u003e\u003ca href=\"https:\/\/www.primuscable.com\/collections\/fiber-cleaning-wipes\" alt=\"Fiber Cleaning Wipes\" target=\"_blank\"\u003e\u003cstrong\u003ewipes.\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003ch4\u003eFeatures\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eHigh performance components and construction\u003c\/li\u003e\n\u003cli\u003eHigh specific strength-to-weight ratio and compact cable design for limited conduit space and tight bends in long cable pulls\u003c\/li\u003e\n\u003cli\u003eHelically stranded core for flexibility, survival in difficult installations, and mechanical protection for the fibers\u003c\/li\u003e\n\u003cli\u003eLower installed cost\u003c\/li\u003e\n\u003cli\u003eHigh performance tight-buffered coating on each fiber for environmental and mechanical protection\u003c\/li\u003e\n\u003cli\u003eHigh crush resistance may eliminate the need for innerduct\u003c\/li\u003e\n\u003cli\u003e900 μm buffer eliminates the need for costly and time-consuming installation of fanout kits or pigtail splices because connectors terminate directly to the fiber.\u003c\/li\u003e\n\u003cli\u003eUL Listed in accordance with NEC section 770.179(a) for use in ducts, plenums and air-handling spaces\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eUsed in trunking, LAN and distribution applications where small size, lightweight, and versatile installation capability are required for ducts, plenums, and air handling spaces\u003c\/li\u003e\n\u003cli\u003eIdeal configuration for a single termination point requiring multiple fibers\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eIndoor\/Outdoor (\"K\" Fluoropolymer Plenum Jacket)\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eIndoor\/Outdoor plenum cables eliminate the need for costly cable transitions in different installation environments\u003c\/li\u003e\n\u003cli\u003eCable materials are UV, water and fungus resistant\u003c\/li\u003e\n\u003cli\u003eHigher fiber counts available than similar cables available by others in subgrouped configuration\u003c\/li\u003e\n\u003cli\u003eJacket is highly chemical resistant for installation in harsh industrial environments\u003c\/li\u003e\n\u003cli\u003eInterlocking armor can be applied to cables as an alternative to conduit installation\u003c\/li\u003e\n\u003cli\u003eCan be installed outside and in plenum or riser pathways inside, eliminating the need to transition cable types between environments\u003c\/li\u003e\n\u003cli\u003e2 to 72 fiber configuration is smaller and lighter than comparable sub-grouped cables, which is ideal for installation in areas with limited space or tight bends\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eStandards List\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eUL 1651\u003c\/li\u003e\n\u003cli\u003eANSI\/NFPA 262\u003c\/li\u003e\n\u003cli\u003eGR-409-CORE\u003c\/li\u003e\n\u003cli\u003eICEA-S-104-696\u003c\/li\u003e\n\u003cli\u003eICEA-S-83-596\u003c\/li\u003e\n\u003cli\u003eTIA-568\u003c\/li\u003e\n\u003cli\u003eTIA-598\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eSpec Sheet\u003c\/h4\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0079\/8874\/0186\/files\/OCC-DX-In-Out-Plenum.pdf?1491\" target=\"_blank\"\u003e \u003cbutton class=\"download-btn\"\u003eSpec Sheet\u003c\/button\u003e \u003c\/a\u003e\u003c\/p\u003e","brand":"OCC","offers":[{"title":"2 Strand","offer_id":31705938231357,"sku":"DX002KALT9QP","price":1.67,"currency_code":"USD","in_stock":true},{"title":"6 Strand","offer_id":31705938264125,"sku":"DX006KALT9QP","price":3.4,"currency_code":"USD","in_stock":true},{"title":"12 Strand","offer_id":31705938296893,"sku":"DX012KALT9QP","price":2.89,"currency_code":"USD","in_stock":true},{"title":"24 Strand","offer_id":31705938329661,"sku":"DX024KALT9QP","price":5.24,"currency_code":"USD","in_stock":true},{"title":"48 Strand","offer_id":31705938362429,"sku":"DX048KALT9QP","price":14.91,"currency_code":"USD","in_stock":true},{"title":"72 Strand","offer_id":31705938395197,"sku":"DX072KALT9QP","price":21.73,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0252\/1897\/3741\/products\/Distribution-10G_2Fiber_4b14db84-8b78-4ae4-930a-15b21b47950d.jpg?v=1581533332"},{"product_id":"distribution-fiber-optic-cable-2-strand-single-mode-9125-indooroutdoor-plenum","title":"Plenum Single Mode Tight Buffer Distribution Fiber Optic Cable for Indoor\/Outdoor Use","description":"\u003cp\u003e\u003cimg height=\"65px\" width=\"115px\" class=\"bulleticons\" alt=\"Made in USA\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0252\/1897\/3741\/files\/Made_In_USA.png?2208\"\u003e \u003cimg height=\"65px\" width=\"76px\" class=\"bulleticons\" alt=\"UL Listed\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0252\/1897\/3741\/files\/UL_LISTED_LOGO_US.png?2209\"\u003e \u003cmeta charset=\"utf-8\"\u003e\u003c\/p\u003e\n\u003ch3\u003e(We do not offer credits or returns for this item.)\u003c\/h3\u003e\n\u003ch3\u003eThis fiber cable is priced per foot and may include a minimum order length.\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eIf you would like to inquire about our custom fiber cable options such as terminated ends, pulleyes, and custom cut lengths, please call or email us.\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch4\u003eDescription\u003c\/h4\u003e\n\u003ch2\u003eOCC's Indoor\/Outdoor Plenum Single Mode 9\/125 Distribution Tight Buffer Fiber Optic Cable\u003c\/h2\u003e\n\u003cp\u003eThis plenum distribution fiber cable is used in trunking, LAN and distribution applications where small size, lightweight, and versatile installation capability are required for ducts, plenums, and air handling spaces. It's ideal for configurations requiring a single termination point with multiple fibers. The plenum distribution fiber optic cable uses high performance components and construction and is UL Listed in accordance with NEC section 770.179(a) for use in ducts, plenums and air-handling spaces.\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eCleaning your fiber connector end faces and components regularly is crucial for avoiding a total network failure. Ensure your optical fiber system is working properly and prevent major network issues with \u003c\/span\u003e\u003ca alt=\"Fiber Cleaning Kits\" href=\"https:\/\/www.primuscable.com\/collections\/fiber-cleaning-kit\" target=\"_blank\"\u003e\u003cstrong\u003efiber cleaning kits,\u003c\/strong\u003e\u003c\/a\u003e\u003cspan\u003e \u003c\/span\u003e\u003ca alt=\"Fiber Cleaning Pens\" href=\"https:\/\/www.primuscable.com\/collections\/fiber-cleaning-pens\" target=\"_blank\"\u003e\u003cstrong\u003epens,\u003c\/strong\u003e\u003c\/a\u003e\u003ca alt=\"Fiber Cleaning Fluids\" href=\"https:\/\/www.primuscable.com\/collections\/fiber-cleaning-fluids\" target=\"_blank\"\u003e\u003cstrong\u003e\u003cspan\u003e \u003c\/span\u003efluids,\u003c\/strong\u003e\u003c\/a\u003e\u003cspan\u003e and \u003c\/span\u003e\u003ca alt=\"Fiber Cleaning Wipes\" href=\"https:\/\/www.primuscable.com\/collections\/fiber-cleaning-wipes\" target=\"_blank\"\u003e\u003cstrong\u003ewipes.\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003ch4\u003eFeatures\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eHigh performance components and construction\u003c\/li\u003e\n\u003cli\u003eHigh specific strength-to-weight ratio and compact cable design for limited conduit space and tight bends in long cable pulls\u003c\/li\u003e\n\u003cli\u003eHelically stranded core for flexibility, survival in difficult installations, and mechanical protection for the fibers\u003c\/li\u003e\n\u003cli\u003eLower installed cost\u003c\/li\u003e\n\u003cli\u003eHigh performance tight-buffered coating on each fiber for environmental and mechanical protection\u003c\/li\u003e\n\u003cli\u003eHigh crush resistance may eliminate the need for innerduct\u003c\/li\u003e\n\u003cli\u003e900 μm buffer eliminates the need for costly and time-consuming installation of fanout kits or pigtail splices because connectors terminate directly to the fiber.\u003c\/li\u003e\n\u003cli\u003eUL Listed in accordance with NEC section 770.179(a) for use in ducts, plenums and air-handling spaces\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eUsed in trunking, LAN and distribution applications where small size, lightweight, and versatile installation capability are required for ducts, plenums, and air handling spaces\u003c\/li\u003e\n\u003cli\u003eIdeal configuration for a single termination point requiring multiple fibers\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eIndoor\/Outdoor (\"K\" Fluoropolymer Plenum Jacket)\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eIndoor\/Outdoor plenum cables eliminate the need for costly cable transitions in different installation environments\u003c\/li\u003e\n\u003cli\u003eCable materials are UV, water and fungus resistant\u003c\/li\u003e\n\u003cli\u003eHigher fiber counts available than similar cables available by others in subgrouped configuration\u003c\/li\u003e\n\u003cli\u003eJacket is highly chemical resistant for installation in harsh industrial environments\u003c\/li\u003e\n\u003cli\u003eInterlocking armor can be applied to cables as an alternative to conduit installation\u003c\/li\u003e\n\u003cli\u003eCan be installed outside and in plenum or riser pathways inside, eliminating the need to transition cable types between environments\u003c\/li\u003e\n\u003cli\u003e2 to 72 fiber configuration is smaller and lighter than comparable sub-grouped cables, which is ideal for installation in areas with limited space or tight bends\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eStandards List\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eUL 1651\u003c\/li\u003e\n\u003cli\u003eANSI\/NFPA 262\u003c\/li\u003e\n\u003cli\u003eGR-409-CORE\u003c\/li\u003e\n\u003cli\u003eICEA-S-104-696\u003c\/li\u003e\n\u003cli\u003eICEA-S-83-596\u003c\/li\u003e\n\u003cli\u003eTIA-568\u003c\/li\u003e\n\u003cli\u003eTIA-598\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eSpec Sheet\u003c\/h4\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0079\/8874\/0186\/files\/OCC-DX-In-Out-Plenum.pdf?1491\" target=\"_blank\"\u003e \u003cbutton class=\"download-btn\"\u003eSpec Sheet\u003c\/button\u003e \u003c\/a\u003e\u003c\/p\u003e","brand":"OCC","offers":[{"title":"2 Strand","offer_id":31710170349629,"sku":"DX002KSLX9YP","price":0.86,"currency_code":"USD","in_stock":true},{"title":"6 Strand","offer_id":31710170382397,"sku":"DX006KSLX9YP","price":0.82,"currency_code":"USD","in_stock":true},{"title":"12 Strand","offer_id":31710170415165,"sku":"DX012KSLX9YP","price":1.38,"currency_code":"USD","in_stock":true},{"title":"24 Strand","offer_id":31710170447933,"sku":"DX024KSLX9YP","price":2.62,"currency_code":"USD","in_stock":true},{"title":"48 Strand","offer_id":31710170480701,"sku":"DX048KSLX9YP","price":3.7,"currency_code":"USD","in_stock":true},{"title":"72 Strand","offer_id":31710170513469,"sku":"DX072KSLX9YP","price":5.6,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0252\/1897\/3741\/products\/DX002KSLX9YP_L_eeac92d9-da07-4a1a-81db-44d99168924b.jpg?v=1567190618"},{"product_id":"armored-fiber-optic-cable-2-strand-single-mode-9125-indooroutdoor-distribution-plenum","title":"Armored Plenum Single Mode Fiber Optic Cable for Indoor\/Outdoor Distribution","description":"\u003cp\u003e\u003cimg height=\"65px\" width=\"115px\" class=\"bulleticons\" alt=\"Made in USA\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0252\/1897\/3741\/files\/Made_In_USA.png?2208\"\u003e \u003cimg height=\"65px\" width=\"76px\" class=\"bulleticons\" alt=\"UL Listed\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0252\/1897\/3741\/files\/UL_LISTED_LOGO_US.png?2209\"\u003e \u003cmeta charset=\"utf-8\"\u003e\u003c\/p\u003e\n\u003ch3\u003e(We do not offer credits or returns for this item.)\u003c\/h3\u003e\n\u003ch3\u003eThis fiber cable is priced per foot and may include a minimum order length.\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eIf you would like to inquire about our custom fiber cable options such as terminated ends, pulleyes, and custom cut lengths, please call or email us.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003ci\u003ePlease call for shipping quote\u003c\/i\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch4\u003eDescription\u003c\/h4\u003e\n\u003ch2\u003eSingle Mode 9\/125 OS2 Armored Fiber Cable - Aluminum Interlocking Armor\u003c\/h2\u003e\n\u003cp\u003eThis armored plenum fiber cable is ideal for industrial and other installations requiring a metallic armor and has a greater flexibility than standard corrugated steel-armored (CST) cables. The interlocking preloaded armor may eliminate the need for conduit, reducing installation costs. The interlocking armor can be easily removed leaving an intact inner plenum rated cable for installation into plenums and air-handling spaces.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eIdeal for industrial and other installations requiring a metallic conduit\u003c\/li\u003e\n\u003cli\u003eInterlocking pre-loaded armor may eliminate the need for conduit, reducing installation costs\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eCleaning your fiber connector end faces and components regularly is crucial for avoiding a total network failure. Ensure your optical fiber system is working properly and prevent major network issues with \u003ca alt=\"Fiber Cleaning Kits\" href=\"https:\/\/www.primuscable.com\/collections\/fiber-cleaning-kit\" target=\"_blank\"\u003e\u003cstrong\u003e fiber cleaning kits,\u003c\/strong\u003e\u003c\/a\u003e \u003ca alt=\"Fiber Cleaning Pens\" href=\"https:\/\/www.primuscable.com\/collections\/fiber-cleaning-pens\" target=\"_blank\"\u003e\u003cstrong\u003e pens,\u003c\/strong\u003e\u003c\/a\u003e\u003ca alt=\"Fiber Cleaning Fluids\" href=\"https:\/\/www.primuscable.com\/collections\/fiber-cleaning-fluids\" target=\"_blank\"\u003e\u003cstrong\u003e fluids,\u003c\/strong\u003e\u003c\/a\u003e and \u003ca alt=\"Fiber Cleaning Wipes\" href=\"https:\/\/www.primuscable.com\/collections\/fiber-cleaning-wipes\" target=\"_blank\"\u003e\u003cstrong\u003ewipes.\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003ch4\u003eFeatures\u003c\/h4\u003e\n\u003ch3\u003e\u003cspan style=\"text-decoration: underline;\"\u003eFeatures\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eCable materials are Indoor\/Outdoor – UL-listed OFCR and UV, water and fungus resistant\u003c\/li\u003e\n\u003cli\u003eUL Listed in accordance with NEC section 770.179(b) for use in vertical runs in building risers or from floor to floor\u003c\/li\u003e\n\u003cli\u003eAluminum interlocking armor with PVC overjacket\u003c\/li\u003e\n\u003cli\u003eInterlocking armor can be easily removed leaving an intact inner cable\u003c\/li\u003e\n\u003cli\u003eGreater flexibility than standard corrugated steel armored (CST) cables\u003c\/li\u003e\n\u003cli\u003eIdeal for locations that require conduit for cable protection\u003c\/li\u003e\n\u003cli\u003eWide operating temperature of -40°C to +85°C\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eStandards\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eOptical Cable Corporation's Indoor\/Outdoor tight-buffered fiber optic cables meet the functional requirements of the following standards:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eUL 1666\u003c\/li\u003e\n\u003cli\u003eUL 1651\u003c\/li\u003e\n\u003cli\u003eICEA-S-83-596\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eSpecifications\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eOperating Temp: -40°C to +85°C\u003c\/li\u003e\n\u003cli\u003eStorage Temp: -55°C to +85°C\u003c\/li\u003e\n\u003cli\u003eInstall Temp: 0°C to +60°C\u003c\/li\u003e\n\u003cli\u003eFlame Retardancy: UL Listed Type OFCR (UL 1666)\u003c\/li\u003e\n\u003cli\u003eCrush Resist: 650 N\/cm\u003c\/li\u003e\n\u003cli\u003eImpact Resist: 20 impacts\u003c\/li\u003e\n\u003cli\u003eFlex Resist: 25 cycles\u003c\/li\u003e\n\u003cli\u003eJacket Type: D Inner, A Outer\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0079\/8874\/0186\/files\/OCC-Indoor-Outdoor-OFCR-Armered-Fiber-Specs.pdf?1615\" target=\"_blank\"\u003e \u003cbutton class=\"download-btn\"\u003eFiber Specifications Chart\u003c\/button\u003e \u003c\/a\u003e\u003c\/p\u003e\n\u003ch4\u003eAdditional Information\u003c\/h4\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0079\/8874\/0186\/files\/OCC-Ultra-Fox-perf_chart-1.pdf?1510\" target=\"_blank\"\u003e \u003cbutton class=\"download-btn\"\u003eFiber Performance Chart\u003c\/button\u003e \u003c\/a\u003e \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0079\/8874\/0186\/files\/OCC-Fiber_Optic_Field_Testing_Guidelines_Rev_A-1.pdf?1613\" target=\"_blank\"\u003e \u003cbutton class=\"download-btn\"\u003eFiber Optic Cable Field Testing Guidelines\u003c\/button\u003e \u003c\/a\u003e \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0079\/8874\/0186\/files\/OCC-Installation-Aerial_Lashing_Guidelines_Rev_A-1.pdf?1613\" target=\"_blank\"\u003e \u003cbutton class=\"download-btn\"\u003eFiber Optic Cable Aerial Lashing Guidelines\u003c\/button\u003e \u003c\/a\u003e \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0079\/8874\/0186\/files\/OCC-Installation-Direct_Burial_Guidelines_Rev_A-1.pdf?1613\" target=\"_blank\"\u003e \u003cbutton class=\"download-btn\"\u003eFiber Optic Cable Direct Burial Guidelines\u003c\/button\u003e \u003c\/a\u003e \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0079\/8874\/0186\/files\/OCC-Installation-General_Guidelines_Rev_B-1.pdf?1613\" target=\"_blank\"\u003e \u003cbutton class=\"download-btn\"\u003eFiber Optic Cable General Guidelines\u003c\/button\u003e \u003c\/a\u003e \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0079\/8874\/0186\/files\/OCC-Installation-Conduit_Guidelines_Rev_A-1.pdf?1613\" target=\"_blank\"\u003e \u003cbutton class=\"download-btn\"\u003eFiber Optic Cable Conduit Guidelines\u003c\/button\u003e \u003c\/a\u003e \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0079\/8874\/0186\/files\/OCC-Storage_Handling_Rev_B-1.pdf?1613\" target=\"_blank\"\u003e \u003cbutton class=\"download-btn\"\u003eFiber Optic Cable Storage and Handling Guidelines\u003c\/button\u003e \u003c\/a\u003e \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0079\/8874\/0186\/files\/OCC-Interlock_Armor_CST_Cable_Grip_Installation_Procedure_Rev._7-1.pdf?1613\" target=\"_blank\"\u003e \u003cbutton class=\"download-btn\"\u003eILA and CST Cables Pulling Grip Installation Procedure\u003c\/button\u003e \u003c\/a\u003e\u003c\/p\u003e","brand":"OCC","offers":[{"title":"2 Strand","offer_id":31730368348221,"sku":"DX002KSLX9YPI6","price":0.0,"currency_code":"USD","in_stock":true},{"title":"6 Strand","offer_id":31730368413757,"sku":"DX006KSLX9YPI6","price":4.82,"currency_code":"USD","in_stock":true},{"title":"12 Strand","offer_id":31730368446525,"sku":"DX012KSLX9YPI6","price":0.0,"currency_code":"USD","in_stock":true},{"title":"24 Strand","offer_id":31730368479293,"sku":"DX024KSLX9YPI6","price":0.0,"currency_code":"USD","in_stock":true},{"title":"48 Strand","offer_id":31730368512061,"sku":"DX048KSLX9YPI6","price":9.7,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0252\/1897\/3741\/products\/02Strand-SM_d7051451-daa6-42ef-92e6-8aa0ab24b686.png?v=1567190765"},{"product_id":"armored-fiber-optic-cable-2-strand-multimode-50125-10-gig-om3-indooroutdoor-distribution-plenum","title":"Armored Plenum Fiber Optic Cable, Multimode 10 Gig OM3, Indoor\/Outdoor Distribution","description":"\u003cp\u003e\u003cimg height=\"65px\" width=\"115px\" class=\"bulleticons\" alt=\"Made in USA\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0252\/1897\/3741\/files\/Made_In_USA.png?2208\"\u003e \u003cimg height=\"65px\" width=\"76px\" class=\"bulleticons\" alt=\"UL Listed\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0252\/1897\/3741\/files\/UL_LISTED_LOGO_US.png?2209\"\u003e \u003cmeta charset=\"utf-8\"\u003e\u003c\/p\u003e\n\u003ch5\u003e(We do not offer credits or returns for this item.)\u003c\/h5\u003e\n\u003ch5\u003eThis fiber cable is priced per foot and may include a minimum order length.\u003c\/h5\u003e\n\u003cp\u003e\u003cstrong\u003eIf you would like to inquire about our custom fiber cable options such as terminated ends, pulleyes, and custom cut lengths, please call or email us.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003ci\u003ePlease call for shipping quote\u003c\/i\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch4\u003eDescription\u003c\/h4\u003e\n\u003ch2\u003eMultiMode 50\/125 OM3 Armored Fiber Cable - Aluminum Interlocking Armor\u003c\/h2\u003e\n\u003cp\u003eThis armored plenum fiber cable is ideal for industrial and other installations requiring a metallic armor and has a greater flexibility than standard corrugated steel-armored (CST) cables. The interlocking preloaded armor may eliminate the need for conduit, reducing installation costs. The interlocking armor can be easily removed leaving an intact inner plenum rated cable for installation into plenums and air-handling spaces.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eIdeal for industrial and other installations requiring a metallic conduit\u003c\/li\u003e\n\u003cli\u003eInterlocking pre-loaded armor may eliminate the need for conduit, reducing installation costs\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eFeatures\u003c\/h4\u003e\n\u003ch3\u003e\u003cspan style=\"text-decoration: underline;\"\u003eFeatures\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eCable materials are Indoor\/Outdoor – UL-listed OFCR and UV, water and fungus resistant\u003c\/li\u003e\n\u003cli\u003eUL Listed in accordance with NEC section 770.179(b) for use in vertical runs in building risers or from floor to floor\u003c\/li\u003e\n\u003cli\u003eAluminum interlocking armor with PVC overjacket\u003c\/li\u003e\n\u003cli\u003eInterlocking armor can be easily removed leaving an intact inner cable\u003c\/li\u003e\n\u003cli\u003eGreater flexibility than standard corrugated steel armored (CST) cables\u003c\/li\u003e\n\u003cli\u003eIdeal for locations that require conduit for cable protection\u003c\/li\u003e\n\u003cli\u003eWide operating temperature of -40°C to +85°C\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eStandards\u003c\/h3\u003e\n\u003cp\u003eOptical Cable Corporation's Indoor\/Outdoor tight-buffered fiber optic cables meet the functional requirements of the following standards:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eUL 1666\u003c\/li\u003e\n\u003cli\u003eUL 1651\u003c\/li\u003e\n\u003cli\u003eICEA-S-83-596\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eSpecifications\u003c\/h4\u003e\n\u003ch3\u003eCharacteristics\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eOperating Temp: -40°C to +85°C\u003c\/li\u003e\n\u003cli\u003eStorage Temp: -55°C to +85°C\u003c\/li\u003e\n\u003cli\u003eInstall Temp: 0°C to +60°C\u003c\/li\u003e\n\u003cli\u003eFlame Retardancy: UL Listed Type OFCR (UL 1666)\u003c\/li\u003e\n\u003cli\u003eCrush Resist: 650 N\/cm\u003c\/li\u003e\n\u003cli\u003eImpact Resist: 20 impacts\u003c\/li\u003e\n\u003cli\u003eFlex Resist: 25 cycles\u003c\/li\u003e\n\u003cli\u003eJacket Type: D Inner, A Outer\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0079\/8874\/0186\/files\/OCC-Indoor-Outdoor-OFCR-Armered-Fiber-Specs.pdf?1615\" target=\"_blank\"\u003e \u003cbutton class=\"download-btn\"\u003eFiber Specifications Chart\u003c\/button\u003e \u003c\/a\u003e\u003c\/p\u003e\n\u003ch4\u003eAdditional Information\u003c\/h4\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0079\/8874\/0186\/files\/OCC-Ultra-Fox-perf_chart-1.pdf?1510\" target=\"_blank\"\u003e \u003cbutton class=\"download-btn\"\u003eFiber Performance Chart\u003c\/button\u003e \u003c\/a\u003e \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0079\/8874\/0186\/files\/OCC-Fiber_Optic_Field_Testing_Guidelines_Rev_A-1.pdf?1613\" target=\"_blank\"\u003e \u003cbutton class=\"download-btn\"\u003eFiber Optic Cable Field Testing Guidelines\u003c\/button\u003e \u003c\/a\u003e \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0079\/8874\/0186\/files\/OCC-Installation-Aerial_Lashing_Guidelines_Rev_A-1.pdf?1613\" target=\"_blank\"\u003e \u003cbutton class=\"download-btn\"\u003eFiber Optic Cable Aerial Lashing Guidelines\u003c\/button\u003e \u003c\/a\u003e \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0079\/8874\/0186\/files\/OCC-Installation-Direct_Burial_Guidelines_Rev_A-1.pdf?1613\" target=\"_blank\"\u003e \u003cbutton class=\"download-btn\"\u003eFiber Optic Cable Direct Burial Guidelines\u003c\/button\u003e \u003c\/a\u003e \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0079\/8874\/0186\/files\/OCC-Installation-General_Guidelines_Rev_B-1.pdf?1613\" target=\"_blank\"\u003e \u003cbutton class=\"download-btn\"\u003eFiber Optic Cable General Guidelines\u003c\/button\u003e \u003c\/a\u003e \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0079\/8874\/0186\/files\/OCC-Installation-Conduit_Guidelines_Rev_A-1.pdf?1613\" target=\"_blank\"\u003e \u003cbutton class=\"download-btn\"\u003eFiber Optic Cable Conduit Guidelines\u003c\/button\u003e \u003c\/a\u003e \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0079\/8874\/0186\/files\/OCC-Storage_Handling_Rev_B-1.pdf?1613\" target=\"_blank\"\u003e \u003cbutton class=\"download-btn\"\u003eFiber Optic Cable Storage and Handling Guidelines\u003c\/button\u003e \u003c\/a\u003e \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0079\/8874\/0186\/files\/OCC-Interlock_Armor_CST_Cable_Grip_Installation_Procedure_Rev._7-1.pdf?1613\" target=\"_blank\"\u003e \u003cbutton class=\"download-btn\"\u003eILA and CST Cables Pulling Grip Installation Procedure\u003c\/button\u003e \u003c\/a\u003e\u003c\/p\u003e","brand":"OCC","offers":[{"title":"2 Strand","offer_id":31730683183165,"sku":"DX002KALT9QPI6","price":0.0,"currency_code":"USD","in_stock":true},{"title":"6 Strand","offer_id":31730683215933,"sku":"DX006KALT9QPI6","price":5.16,"currency_code":"USD","in_stock":true},{"title":"12 Strand","offer_id":31730683248701,"sku":"DX012KALT9QPI6","price":7.22,"currency_code":"USD","in_stock":true},{"title":"24 Strand","offer_id":31730683281469,"sku":"DX024KALT9QPI6","price":0.0,"currency_code":"USD","in_stock":true},{"title":"48 Strand","offer_id":31730683314237,"sku":"DX048KALT9QPI6","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0252\/1897\/3741\/products\/02Strand-10G_ad50c625-7ad3-4ec5-b7dc-3b29ae74ce4d.png?v=1567190769"},{"product_id":"armored-fiber-optic-cable-2-strand-multimode-50125-10-gig-om4-indooroutdoor-distribution-plenum","title":"Armored Plenum Fiber Optic Cable, Multimode 10 Gig OM4, Indoor\/Outdoor Distribution","description":"\u003cp\u003e\u003cimg height=\"65px\" width=\"115px\" class=\"bulleticons\" alt=\"Made in USA\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0252\/1897\/3741\/files\/Made_In_USA.png?2208\"\u003e \u003cimg height=\"65px\" width=\"76px\" class=\"bulleticons\" alt=\"UL Listed\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0252\/1897\/3741\/files\/UL_LISTED_LOGO_US.png?2209\"\u003e \u003cmeta charset=\"utf-8\"\u003e\u003c\/p\u003e\n\u003ch3\u003e(We do not offer credits or returns for this item.)\u003c\/h3\u003e\n\u003ch3\u003eThis fiber cable is priced per foot and may include a minimum order length.\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eIf you would like to inquire about our custom fiber cable options such as terminated ends, pulleyes, and custom cut lengths, please call or email us.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003ci\u003ePlease call for shipping quote\u003c\/i\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch4\u003eDescription\u003c\/h4\u003e\n\u003ch2\u003eMultiMode 50\/125 OM4 Armored Plenum Fiber Cable - Aluminum Interlocking Armored\u003c\/h2\u003e\n\u003cp\u003eThis armored plenum fiber cable is ideal for industrial and other installations requiring a metallic armor and has a greater flexibility than standard corrugated steel-armored (CST) cables. The interlocking preloaded armor may eliminate the need for conduit, reducing installation costs. The interlocking armor can be easily removed leaving an intact inner plenum rated cable for installation into plenums and air-handling spaces.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eIdeal for industrial and other installations requiring a metallic conduit\u003c\/li\u003e\n\u003cli\u003eInterlocking pre-loaded armor may eliminate the need for conduit, reducing installation costs\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eCleaning your fiber connector end faces and components regularly is crucial for avoiding a total network failure. Ensure your optical fiber system is working properly and prevent major network issues with \u003ca alt=\"Fiber Cleaning Kits\" href=\"https:\/\/www.primuscable.com\/collections\/fiber-cleaning-kit\" target=\"_blank\"\u003e\u003cstrong\u003e fiber cleaning kits,\u003c\/strong\u003e\u003c\/a\u003e \u003ca alt=\"Fiber Cleaning Pens\" href=\"https:\/\/www.primuscable.com\/collections\/fiber-cleaning-pens\" target=\"_blank\"\u003e\u003cstrong\u003e pens,\u003c\/strong\u003e\u003c\/a\u003e\u003ca alt=\"Fiber Cleaning Fluids\" href=\"https:\/\/www.primuscable.com\/collections\/fiber-cleaning-fluids\" target=\"_blank\"\u003e\u003cstrong\u003e fluids,\u003c\/strong\u003e\u003c\/a\u003e and \u003ca alt=\"Fiber Cleaning Wipes\" href=\"https:\/\/www.primuscable.com\/collections\/fiber-cleaning-wipes\" target=\"_blank\"\u003e\u003cstrong\u003ewipes.\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003ch4\u003eFeatures\u003c\/h4\u003e\n\u003ch3\u003e\u003cspan style=\"text-decoration: underline;\"\u003eFeatures\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eCable materials are Indoor\/Outdoor – UL-listed OFCR and UV, water and fungus resistant\u003c\/li\u003e\n\u003cli\u003eUL Listed in accordance with NEC section 770.179(b) for use in vertical runs in building risers or from floor to floor\u003c\/li\u003e\n\u003cli\u003eAluminum interlocking armor with PVC overjacket\u003c\/li\u003e\n\u003cli\u003eInterlocking armor can be easily removed leaving an intact inner cable\u003c\/li\u003e\n\u003cli\u003eGreater flexibility than standard corrugated steel armored (CST) cables\u003c\/li\u003e\n\u003cli\u003eIdeal for locations that require conduit for cable protection\u003c\/li\u003e\n\u003cli\u003eWide operating temperature of -40°C to +85°C\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eStandards\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eOptical Cable Corporation's Indoor\/Outdoor tight-buffered fiber optic cables meet the functional requirements of the following standards:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eUL 1666\u003c\/li\u003e\n\u003cli\u003eUL 1651\u003c\/li\u003e\n\u003cli\u003eICEA-S-83-596\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eSpecifications\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eOperating Temp: -40°C to +85°C\u003c\/li\u003e\n\u003cli\u003eStorage Temp: -55°C to +85°C\u003c\/li\u003e\n\u003cli\u003eInstall Temp: 0°C to +60°C\u003c\/li\u003e\n\u003cli\u003eFlame Retardancy: UL Listed Type OFCR (UL 1666)\u003c\/li\u003e\n\u003cli\u003eCrush Resist: 650 N\/cm\u003c\/li\u003e\n\u003cli\u003eImpact Resist: 20 impacts\u003c\/li\u003e\n\u003cli\u003eFlex Resist: 25 cycles\u003c\/li\u003e\n\u003cli\u003eJacket Type: D Inner, A Outer\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0079\/8874\/0186\/files\/OCC-Indoor-Outdoor-OFCR-Armered-Fiber-Specs.pdf?1615\" target=\"_blank\"\u003e \u003cbutton class=\"download-btn\"\u003eFiber Specifications Chart\u003c\/button\u003e \u003c\/a\u003e\u003c\/p\u003e\n\u003ch4\u003eAdditional Information\u003c\/h4\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0079\/8874\/0186\/files\/OCC-Ultra-Fox-perf_chart-1.pdf?1510\" target=\"_blank\"\u003e \u003cbutton class=\"download-btn\"\u003eFiber Performance Chart\u003c\/button\u003e \u003c\/a\u003e \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0079\/8874\/0186\/files\/OCC-Fiber_Optic_Field_Testing_Guidelines_Rev_A-1.pdf?1613\" target=\"_blank\"\u003e \u003cbutton class=\"download-btn\"\u003eFiber Optic Cable Field Testing Guidelines\u003c\/button\u003e \u003c\/a\u003e \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0079\/8874\/0186\/files\/OCC-Installation-Aerial_Lashing_Guidelines_Rev_A-1.pdf?1613\" target=\"_blank\"\u003e \u003cbutton class=\"download-btn\"\u003eFiber Optic Cable Aerial Lashing Guidelines\u003c\/button\u003e \u003c\/a\u003e \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0079\/8874\/0186\/files\/OCC-Installation-Direct_Burial_Guidelines_Rev_A-1.pdf?1613\" target=\"_blank\"\u003e \u003cbutton class=\"download-btn\"\u003eFiber Optic Cable Direct Burial Guidelines\u003c\/button\u003e \u003c\/a\u003e \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0079\/8874\/0186\/files\/OCC-Installation-General_Guidelines_Rev_B-1.pdf?1613\" target=\"_blank\"\u003e \u003cbutton class=\"download-btn\"\u003eFiber Optic Cable General Guidelines\u003c\/button\u003e \u003c\/a\u003e \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0079\/8874\/0186\/files\/OCC-Installation-Conduit_Guidelines_Rev_A-1.pdf?1613\" target=\"_blank\"\u003e \u003cbutton class=\"download-btn\"\u003eFiber Optic Cable Conduit Guidelines\u003c\/button\u003e \u003c\/a\u003e \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0079\/8874\/0186\/files\/OCC-Storage_Handling_Rev_B-1.pdf?1613\" target=\"_blank\"\u003e \u003cbutton class=\"download-btn\"\u003eFiber Optic Cable Storage and Handling Guidelines\u003c\/button\u003e \u003c\/a\u003e \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0079\/8874\/0186\/files\/OCC-Interlock_Armor_CST_Cable_Grip_Installation_Procedure_Rev._7-1.pdf?1613\" target=\"_blank\"\u003e \u003cbutton class=\"download-btn\"\u003eILA and CST Cables Pulling Grip Installation Procedure\u003c\/button\u003e \u003c\/a\u003e\u003c\/p\u003e","brand":"OCC","offers":[{"title":"2 Strand","offer_id":31730836209725,"sku":"DX002KALE9QPI6","price":0.0,"currency_code":"USD","in_stock":true},{"title":"6 Strand","offer_id":31730836242493,"sku":"DX006KALE9QPI6","price":0.0,"currency_code":"USD","in_stock":true},{"title":"12 Strand","offer_id":31730836275261,"sku":"DX012KALE9QPI6","price":0.0,"currency_code":"USD","in_stock":true},{"title":"24 Strand","offer_id":31730836340797,"sku":"DX024KALE9QPI6","price":0.0,"currency_code":"USD","in_stock":true},{"title":"48 Strand","offer_id":31730836373565,"sku":"DX048KALE9QPI6","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0252\/1897\/3741\/products\/02Strand-10G_fe015512-f811-4ea5-827c-83c6a6afa38b.png?v=1567190770"},{"product_id":"armored-fiber-optic-cable-2-strand-single-mode-9125-indooroutdoor-distribution-riser","title":"Armored Riser Fiber Optic Cable, Single Mode, Indoor\/Outdoor Distribution","description":"\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0252\/1897\/3741\/files\/Made_In_USA.png?2208\" alt=\"Made in USA\" class=\"bulleticons\" width=\"115px\" height=\"65px\"\u003e\u003cspan\u003e \u003c\/span\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0252\/1897\/3741\/files\/UL_LISTED_LOGO_US.png?2209\" alt=\"UL Listed\" class=\"bulleticons\" width=\"76px\" height=\"65px\"\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch3\u003e(We do not offer credits or returns for this item.)\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eFor volume quotes or to inquire about our custom fiber cable options such as terminated ends, pulleyes, and custom cut lengths, please call or email us.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003ci\u003ePlease call for shipping quote\u003c\/i\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch4\u003eDescription\u003c\/h4\u003e\n\u003ch2\u003eSingle Mode, 9\/125, Aluminum Interlocking Armored Distribution Cable, OFCR Riser Rated, Indoor\/Outdoor, Price Per Foot\u003c\/h2\u003e\n\u003cp\u003eThis armored riser fiber cable is ideal for industrial and other installations requiring a metallic armor and has a greater flexibility than standard corrugated steel-armored (CST) cables. The interlocking preloaded armor may eliminate the need for conduit, reducing installation costs. The interlocking armor can be easily removed leaving an intact inner riser rated cable for installation into building risers or from floor to floor.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eIdeal for industrial and other installations requiring a metallic armor\u003c\/li\u003e\n\u003cli\u003eInterlocking preloaded armor may eliminate the need for conduit, reducing installation costs\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eCleaning your fiber connector end faces and components regularly is crucial for avoiding a total network failure. Ensure your optical fiber system is working properly and prevent major network issues with \u003ca href=\"https:\/\/www.primuscable.com\/collections\/fiber-cleaning-kit\" alt=\"Fiber Cleaning Kits\" target=\"_blank\"\u003e\u003cstrong\u003e fiber cleaning kits,\u003c\/strong\u003e\u003c\/a\u003e \u003ca href=\"https:\/\/www.primuscable.com\/collections\/fiber-cleaning-pens\" alt=\"Fiber Cleaning Pens\" target=\"_blank\"\u003e\u003cstrong\u003e pens,\u003c\/strong\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/www.primuscable.com\/collections\/fiber-cleaning-fluids\" alt=\"Fiber Cleaning Fluids\" target=\"_blank\"\u003e\u003cstrong\u003e fluids,\u003c\/strong\u003e\u003c\/a\u003e and \u003ca href=\"https:\/\/www.primuscable.com\/collections\/fiber-cleaning-wipes\" alt=\"Fiber Cleaning Wipes\" target=\"_blank\"\u003e\u003cstrong\u003ewipes.\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003ch4\u003eFeatures\u003c\/h4\u003e\n\u003ch3\u003e\u003cspan style=\"text-decoration: underline;\"\u003eFeatures\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eUL Listed in accordance with NEC section 770.179(b) for use in vertical runs in building risers or from floor to floor\u003c\/li\u003e\n\u003cli\u003eAluminum interlocking armor with PVC overjacket\u003c\/li\u003e\n\u003cli\u003eInterlocking armor can be easily removed leaving an intact inner cable\u003c\/li\u003e\n\u003cli\u003eGreater flexibility than standard corrugated steel armored (CST) cables\u003c\/li\u003e\n\u003cli\u003eIdeal for locations that require conduit for cable protection\u003c\/li\u003e\n\u003cli\u003eWide operating temperature of -40™C to +85™C\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eSpecifications\u003c\/h4\u003e\n\u003ch3\u003eLaser Ultra-Fox™ Fiber Performance\u003c\/h3\u003e\n\u003cdiv class=\"table-responsive\"\u003e\n\u003ctable class=\"table table-striped table-bordered text-center\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eFiber Code\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp class=\"p1\"\u003eSLX\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"vertical-align: middle;\"\u003e\n\u003cp class=\"p1\"\u003eIndustry Standard Designation\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp class=\"p1\"\u003eLow Water Peak\u003c\/p\u003e\n\u003cp class=\"p1\"\u003eSingle-Mode\u003c\/p\u003e\n\u003cp class=\"p1\"\u003eITU-T G.652.D\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCore\/Cladding Diameter (μm)\u003c\/td\u003e\n\u003ctd\u003e9\/125\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWavelength (nm)\u003c\/td\u003e\n\u003ctd\u003e1310\/1550\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Cabled Attenuation (dB\/km)\u003c\/td\u003e\n\u003ctd\u003e0.5\/0.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePrimary Coating Diameter (μm)\u003c\/td\u003e\n\u003ctd\u003e245\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSecondary Buffer Diameter (μm)\u003c\/td\u003e\n\u003ctd\u003e900\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZero Dispersion Slope (ps\/nm2-km)\u003c\/td\u003e\n\u003ctd\u003e0.092\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProof Test Level (kpsi)\u003c\/td\u003e\n\u003ctd\u003e100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003ch3\u003eInstallation and Operating Characteristics\u003c\/h3\u003e\n\u003cp style=\"text-align: center;\"\u003eInner Cable\u003c\/p\u003e\n\u003cdiv class=\"table-responsive\"\u003e\n\u003ctable class=\"table table-striped table-bordered text-center\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eInstallation\u003c\/td\u003e\n\u003ctd\u003eOperating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Tensile Load\u003c\/td\u003e\n\u003ctd\u003e3,000 N (670 lbs)\u003c\/td\u003e\n\u003ctd\u003e1,000 N (220 lbs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMin Bend Radius\u003c\/td\u003e\n\u003ctd\u003e13.4 cm (5.3 in)\u003c\/td\u003e\n\u003ctd\u003e8.9 cm (3.5 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp style=\"text-align: center;\"\u003eOuter Cable\u003c\/p\u003e\n\u003cdiv class=\"table-responsive\"\u003e\n\u003ctable class=\"table table-striped table-bordered text-center\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eInstallation\u003c\/td\u003e\n\u003ctd\u003eOperating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Tensile Load\u003c\/td\u003e\n\u003ctd\u003e1,350 N (300 lbs)\u003c\/td\u003e\n\u003ctd\u003e400 N (90 lbs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMin Bend Radius\u003c\/td\u003e\n\u003ctd\u003e33.4 cm (13.1 in)\u003c\/td\u003e\n\u003ctd\u003e25.1 cm (9.9 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003ch3\u003eMechanical and Environmental\u003c\/h3\u003e\n\u003cdiv class=\"table-responsive\"\u003e\n\u003ctable class=\"table table-striped table-bordered text-center\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eInner Cable\u003c\/td\u003e\n\u003ctd\u003eEntire Cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eImpact Resistance EIA\/TIA-455-25A\u003c\/td\u003e\n\u003ctd\u003e1,500 Impacts\u003c\/td\u003e\n\u003ctd\u003e20 Impacts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFlex Resistance\u003c\/td\u003e\n\u003ctd\u003e2,000 N\/cm\u003c\/td\u003e\n\u003ctd\u003e25 N\/cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCrush Resistance TIA\/EIA-455-41A\u003c\/td\u003e\n\u003ctd\u003e1,800 N\/cm\u003c\/td\u003e\n\u003ctd\u003e650 N\/cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-40°C to +85°C\u003c\/td\u003e\n\u003ctd\u003e40°C to +85°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-55°C to +85°C\u003c\/td\u003e\n\u003ctd\u003e-55°C to +85°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInstallation Temperature (actual temp. of cable)\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp class=\"p1\"\u003e-10°C to +60°C\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e0°C to +60°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFlame Retardancy\u003c\/td\u003e\n\u003ctd\u003eUL Listed Type OFNR (UL 1666) and FT4 (CSA C22.2 No. 232)\u003c\/td\u003e\n\u003ctd\u003eUL Listed Type OFCR (UL 1666) and FT4 (CSA C22.2 No. 232)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003ch3\u003eCable Characteristics\u003c\/h3\u003e\n\u003cp style=\"text-align: center;\"\u003eInner Cable\u003c\/p\u003e\n\u003cdiv class=\"table-responsive\"\u003e\n\u003ctable class=\"table table-striped table-bordered text-center\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp class=\"p1\" data-mce-fragment=\"1\"\u003eJacket Color\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp class=\"p1\"\u003eBlack\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"vertical-align: middle;\"\u003e\n\u003cp class=\"p1\"\u003eJacket Material\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp class=\"p1\"\u003eIndoor \/ Outdoor PVC\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBuffer Material\u003c\/td\u003e\n\u003ctd\u003ePVC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Weight\u003c\/td\u003e\n\u003ctd\u003e67 kg\/km (45 lbs\/1000')\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Diameter\u003c\/td\u003e\n\u003ctd\u003e8.9 mm ( 0.35 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp style=\"text-align: center;\"\u003eOuter Cable\u003c\/p\u003e\n\u003cdiv class=\"table-responsive\"\u003e\n\u003ctable class=\"table table-striped table-bordered text-center\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp class=\"p1\" data-mce-fragment=\"1\"\u003eJacket Color\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp class=\"p1\"\u003eYellow\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"vertical-align: middle;\"\u003e\n\u003cp class=\"p1\"\u003eJacket Material\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp class=\"p1\"\u003eIndoor \/ Outdoor PVC\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Weight\u003c\/td\u003e\n\u003ctd\u003e239 kg\/km (161 lbs\/1000')\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Diameter\u003c\/td\u003e\n\u003ctd\u003e16.7 mm ( 0.66 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003ch4\u003eSingle Mode Fiber Information\u003c\/h4\u003e\n\u003cp\u003eSingle mode fiber cable (Synonyms mono-mode optical fiber, single-mode fiber, single-mode optical waveguide, uni-mode fiber) is a single strand of glass fiber with a diameter of 8.3 to 10 microns that has one mode of transmission. Single mode fiber has a relatively narrow diameter, through which only one mode will propagate typically 1310 or 1550nm wavelengths. Single mode fibers carry higher bandwidth than multimode fiber, but require a light source with a narrow spectral width. Single-mode fiber gives you a higher transmission rate and up to 50 times more distance than multimode. The small core and single light-wave virtually eliminate any distortion that could result from overlapping light pulses, providing the least signal attenuation and the highest transmission speeds of any fiber cable type.\u003c\/p\u003e","brand":"OCC","offers":[{"title":"2 Strand","offer_id":31724356468797,"sku":"DX002DSLX9YRI2","price":0.0,"currency_code":"USD","in_stock":true},{"title":"6 Strand","offer_id":31724356501565,"sku":"DX006DSLX9YRI2","price":1.9,"currency_code":"USD","in_stock":true},{"title":"12 Strand","offer_id":31724356534333,"sku":"DX012DSLX9YRI2","price":0.0,"currency_code":"USD","in_stock":true},{"title":"24 Strand","offer_id":31724356567101,"sku":"DX024DSLX9YRI2","price":0.0,"currency_code":"USD","in_stock":true},{"title":"48 Strand","offer_id":31724356599869,"sku":"DX048DSLX9YRI2","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0252\/1897\/3741\/products\/02Strand-SM_c7216681-42e7-4d2d-874c-5ee5da6fbd32.png?v=1567190770"},{"product_id":"armored-fiber-optic-cable-2-strand-multimode-50125-10-gig-om3-indooroutdoor-distribution-riser","title":"Armored Riser Fiber Optic Cable, Multimode 10 Gig OM3, Indoor\/Outdoor Distribution","description":"\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0252\/1897\/3741\/files\/Made_In_USA.png?2208\" alt=\"Made in USA\" class=\"bulleticons\" width=\"115px\" height=\"65px\"\u003e \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0252\/1897\/3741\/files\/UL_LISTED_LOGO_US.png?2209\" alt=\"UL Listed\" class=\"bulleticons\" width=\"76px\" height=\"65px\"\u003e \u003cmeta charset=\"utf-8\"\u003e\u003c\/p\u003e\n\u003ch3\u003e(We do not offer credits or returns for this item.)\u003c\/h3\u003e\n\u003ch3\u003eThis fiber cable is priced per foot and may include a minimum order length.\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eIf you would like to inquire about our custom fiber cable options such as terminated ends, pulleyes, and custom cut lengths, please call or email us.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003ci\u003ePlease call for shipping quote\u003c\/i\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch4\u003eDescription\u003c\/h4\u003e\n\u003ch2\u003eMultiMode 50\/125 OM3 Armored Fiber Cable - Aluminum Interlocking Armor\u003c\/h2\u003e\n\u003cp\u003eThis armored riser fiber cable is ideal for industrial and other installations requiring a metallic armor and has a greater flexibility than standard corrugated steel-armored (CST) cables. The interlocking preloaded armor may eliminate the need for conduit, reducing installation costs. The interlocking armor can be easily removed leaving an intact inner plenum rated cable for installation into plenums and air-handling spaces.\u003c\/p\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eIdeal for industrial and other installations requiring a metallic conduit\u003c\/li\u003e\n\u003cli\u003eInterlocking pre-loaded armor may eliminate the need for conduit, reducing installation costs\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eCleaning your fiber connector end faces and components regularly is crucial for avoiding a total network failure. Ensure your optical fiber system is working properly and prevent major network issues with \u003ca href=\"https:\/\/www.primuscable.com\/collections\/fiber-cleaning-kit\" alt=\"Fiber Cleaning Kits\" target=\"_blank\"\u003e\u003cstrong\u003e fiber cleaning kits,\u003c\/strong\u003e\u003c\/a\u003e \u003ca href=\"https:\/\/www.primuscable.com\/collections\/fiber-cleaning-pens\" alt=\"Fiber Cleaning Pens\" target=\"_blank\"\u003e\u003cstrong\u003e pens,\u003c\/strong\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/www.primuscable.com\/collections\/fiber-cleaning-fluids\" alt=\"Fiber Cleaning Fluids\" target=\"_blank\"\u003e\u003cstrong\u003e fluids,\u003c\/strong\u003e\u003c\/a\u003e and \u003ca href=\"https:\/\/www.primuscable.com\/collections\/fiber-cleaning-wipes\" alt=\"Fiber Cleaning Wipes\" target=\"_blank\"\u003e\u003cstrong\u003ewipes.\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003ch4\u003eFeatures\u003c\/h4\u003e\n\u003ch3\u003e\u003cspan style=\"text-decoration: underline;\"\u003eFeatures\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eCable materials are Indoor\/Outdoor – UL-listed OFCR and UV, water and fungus resistant\u003c\/li\u003e\n\u003cli\u003eUL Listed in accordance with NEC section 770.179(b) for use in vertical runs in building risers or from floor to floor\u003c\/li\u003e\n\u003cli\u003eAluminum interlocking armor with PVC overjacket\u003c\/li\u003e\n\u003cli\u003eInterlocking armor can be easily removed leaving an intact inner cable\u003c\/li\u003e\n\u003cli\u003eGreater flexibility than standard corrugated steel armored (CST) cables\u003c\/li\u003e\n\u003cli\u003eIdeal for locations that require conduit for cable protection\u003c\/li\u003e\n\u003cli\u003eWide operating temperature of -40°C to +85°C\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eStandards\u003c\/h3\u003e\n\u003cp\u003eOptical Cable Corporation's Indoor\/Outdoor tight-buffered fiber optic cables meet the functional requirements of the following standards:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eUL 1666\u003c\/li\u003e\n\u003cli\u003eUL 1651\u003c\/li\u003e\n\u003cli\u003eICEA-S-83-596\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eSpecifications\u003c\/h4\u003e\n\u003ch3\u003eCharacteristics\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eOperating Temp: -40°C to +85°C\u003c\/li\u003e\n\u003cli\u003eStorage Temp: -55°C to +85°C\u003c\/li\u003e\n\u003cli\u003eInstall Temp: 0°C to +60°C\u003c\/li\u003e\n\u003cli\u003eFlame Retardancy: UL Listed Type OFCR (UL 1666)\u003c\/li\u003e\n\u003cli\u003eCrush Resist: 650 N\/cm\u003c\/li\u003e\n\u003cli\u003eImpact Resist: 20 impacts\u003c\/li\u003e\n\u003cli\u003eFlex Resist: 25 cycles\u003c\/li\u003e\n\u003cli\u003eJacket Type: D Inner, A Outer\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0079\/8874\/0186\/files\/OCC-Indoor-Outdoor-OFCR-Armered-Fiber-Specs.pdf?1615\" target=\"_blank\"\u003e \u003cbutton class=\"download-btn\"\u003eFiber Specifications Chart\u003c\/button\u003e \u003c\/a\u003e\u003c\/p\u003e\n\u003ch4\u003eAdditional information\u003c\/h4\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0079\/8874\/0186\/files\/OCC-Ultra-Fox-perf_chart-1.pdf?1510\" target=\"_blank\"\u003e \u003cbutton class=\"download-btn\"\u003eFiber Performance Chart\u003c\/button\u003e \u003c\/a\u003e \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0079\/8874\/0186\/files\/OCC-Fiber_Optic_Field_Testing_Guidelines_Rev_A-1.pdf?1613\" target=\"_blank\"\u003e \u003cbutton class=\"download-btn\"\u003eFiber Optic Cable Field Testing Guidelines\u003c\/button\u003e \u003c\/a\u003e \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0079\/8874\/0186\/files\/OCC-Installation-Aerial_Lashing_Guidelines_Rev_A-1.pdf?1613\" target=\"_blank\"\u003e \u003cbutton class=\"download-btn\"\u003eFiber Optic Cable Aerial Lashing Guidelines\u003c\/button\u003e \u003c\/a\u003e \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0079\/8874\/0186\/files\/OCC-Installation-Direct_Burial_Guidelines_Rev_A-1.pdf?1613\" target=\"_blank\"\u003e \u003cbutton class=\"download-btn\"\u003eFiber Optic Cable Direct Burial Guidelines\u003c\/button\u003e \u003c\/a\u003e \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0079\/8874\/0186\/files\/OCC-Installation-General_Guidelines_Rev_B-1.pdf?1613\" target=\"_blank\"\u003e \u003cbutton class=\"download-btn\"\u003eFiber Optic Cable General Guidelines\u003c\/button\u003e \u003c\/a\u003e \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0079\/8874\/0186\/files\/OCC-Installation-Conduit_Guidelines_Rev_A-1.pdf?1613\" target=\"_blank\"\u003e \u003cbutton class=\"download-btn\"\u003eFiber Optic Cable Conduit Guidelines\u003c\/button\u003e \u003c\/a\u003e \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0079\/8874\/0186\/files\/OCC-Storage_Handling_Rev_B-1.pdf?1613\" target=\"_blank\"\u003e \u003cbutton class=\"download-btn\"\u003eFiber Optic Cable Storage and Handling Guidelines\u003c\/button\u003e \u003c\/a\u003e \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0079\/8874\/0186\/files\/OCC-Interlock_Armor_CST_Cable_Grip_Installation_Procedure_Rev._7-1.pdf?1613\" target=\"_blank\"\u003e \u003cbutton class=\"download-btn\"\u003eILA and CST Cables Pulling Grip Installation Procedure\u003c\/button\u003e \u003c\/a\u003e\u003c\/p\u003e","brand":"OCC","offers":[{"title":"2 Strand","offer_id":31710841307197,"sku":"DX002DALT9QRI2","price":0.0,"currency_code":"USD","in_stock":true},{"title":"6 Strand","offer_id":31710841339965,"sku":"DX006DALT9QRI2","price":2.54,"currency_code":"USD","in_stock":true},{"title":"12 Strand","offer_id":31710841372733,"sku":"DX012DALT9QRI2","price":0.0,"currency_code":"USD","in_stock":true},{"title":"24 Strand","offer_id":31710841405501,"sku":"DX024DALT9QRI2","price":0.0,"currency_code":"USD","in_stock":true},{"title":"48 Strand","offer_id":31710841438269,"sku":"DX048DALT9QRI2","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0252\/1897\/3741\/products\/02Strand-10G_0380b16e-4254-40d9-9269-6cf7a974cd5c.png?v=1567190773"},{"product_id":"armored-fiber-optic-cable-2-strand-multimode-50125-10-gig-om4-indooroutdoor-distribution-riser","title":"Armored Riser Fiber Optic Cable: Multimode 10 Gig OM4 for Indoor\/Outdoor Distribution","description":"\u003cp\u003e\u003cimg height=\"65px\" width=\"115px\" class=\"bulleticons\" alt=\"Made in USA\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0252\/1897\/3741\/files\/Made_In_USA.png?2208\"\u003e \u003cimg height=\"65px\" width=\"76px\" class=\"bulleticons\" alt=\"UL Listed\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0252\/1897\/3741\/files\/UL_LISTED_LOGO_US.png?2209\"\u003e \u003cmeta charset=\"utf-8\"\u003e\u003c\/p\u003e\n\u003ch3\u003e(We do not offer credits or returns for this item.)\u003c\/h3\u003e\n\u003ch3\u003eThis fiber cable is priced per foot and may include a minimum order length.\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eIf you would like to inquire about our custom fiber cable options such as terminated ends, pulleyes, and custom cut lengths, please call or email us.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003ci\u003ePlease call for shipping quote\u003c\/i\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch4\u003eDescription\u003c\/h4\u003e\n\u003ch2\u003e\n\u003cmeta charset=\"utf-8\"\u003e \u003cspan\u003eMultiMode 50\/125 OM4 Armored Riser Fiber Cable with Aluminum Interlocking Armored Design\u003c\/span\u003e\n\u003c\/h2\u003e\n\u003cp\u003e\u003cmeta charset=\"utf-8\"\u003e\u003cspan\u003eThe armored riser fiber cable offers optimal suitability for industrial and similar setups necessitating metallic armor, providing superior flexibility compared to standard corrugated steel-armored (CST) cables. Its interlocking preloaded armor potentially obviates the necessity for conduit, thereby cutting down on installation expenses. Moreover, the interlocking armor can be effortlessly detached, leaving behind an intact inner plenum-rated cable for seamless installation in plenums and air-handling spaces.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eIdeal for industrial and other installations requiring a metallic conduit\u003c\/li\u003e\n\u003cli\u003eInterlocking pre-loaded armor may eliminate the need for conduit, reducing installation costs\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eCleaning your fiber connector end faces and components regularly is crucial for avoiding a total network failure. Ensure your optical fiber system is working properly and prevent major network issues with \u003ca alt=\"Fiber Cleaning Kits\" href=\"https:\/\/www.primuscable.com\/collections\/fiber-cleaning-kit\" target=\"_blank\"\u003e\u003cstrong\u003e fiber cleaning kits,\u003c\/strong\u003e\u003c\/a\u003e \u003ca alt=\"Fiber Cleaning Pens\" href=\"https:\/\/www.primuscable.com\/collections\/fiber-cleaning-pens\" target=\"_blank\"\u003e\u003cstrong\u003e pens,\u003c\/strong\u003e\u003c\/a\u003e\u003ca alt=\"Fiber Cleaning Fluids\" href=\"https:\/\/www.primuscable.com\/collections\/fiber-cleaning-fluids\" target=\"_blank\"\u003e\u003cstrong\u003e fluids,\u003c\/strong\u003e\u003c\/a\u003e and \u003ca alt=\"Fiber Cleaning Wipes\" href=\"https:\/\/www.primuscable.com\/collections\/fiber-cleaning-wipes\" target=\"_blank\"\u003e\u003cstrong\u003ewipes.\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003ch4\u003eFeatures\u003c\/h4\u003e\n\u003ch3\u003e\u003cspan style=\"text-decoration: underline;\"\u003eFeatures\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eCable materials are Indoor\/Outdoor – UL-listed OFCR and UV, water and fungus resistant\u003c\/li\u003e\n\u003cli\u003eUL Listed in accordance with NEC section 770.179(b) for use in vertical runs in building risers or from floor to floor\u003c\/li\u003e\n\u003cli\u003eAluminum interlocking armor with PVC overjacket\u003c\/li\u003e\n\u003cli\u003eInterlocking armor can be easily removed leaving an intact inner cable\u003c\/li\u003e\n\u003cli\u003eGreater flexibility than standard corrugated steel armored (CST) cables\u003c\/li\u003e\n\u003cli\u003eIdeal for locations that require conduit for cable protection\u003c\/li\u003e\n\u003cli\u003eWide operating temperature of -40°C to +85°C\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eStandards\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eOptical Cable Corporation's Indoor\/Outdoor tight-buffered fiber optic cables meet the functional requirements of the following standards:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eUL 1666\u003c\/li\u003e\n\u003cli\u003eUL 1651\u003c\/li\u003e\n\u003cli\u003eICEA-S-83-596\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eSpecifications\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eOperating Temp: -40°C to +85°C\u003c\/li\u003e\n\u003cli\u003eStorage Temp: -55°C to +85°C\u003c\/li\u003e\n\u003cli\u003eInstall Temp: 0°C to +60°C\u003c\/li\u003e\n\u003cli\u003eFlame Retardancy: UL Listed Type OFCR (UL 1666)\u003c\/li\u003e\n\u003cli\u003eCrush Resist: 650 N\/cm\u003c\/li\u003e\n\u003cli\u003eImpact Resist: 20 impacts\u003c\/li\u003e\n\u003cli\u003eFlex Resist: 25 cycles\u003c\/li\u003e\n\u003cli\u003eJacket Type: D Inner, A Outer\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0079\/8874\/0186\/files\/OCC-Indoor-Outdoor-OFCR-Armered-Fiber-Specs.pdf?1615\" target=\"_blank\"\u003e \u003cbutton class=\"download-btn\"\u003eFiber Specifications Chart\u003c\/button\u003e \u003c\/a\u003e\u003c\/p\u003e\n\u003ch4\u003eAdditional Information\u003c\/h4\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0079\/8874\/0186\/files\/OCC-Ultra-Fox-perf_chart-1.pdf?1510\" target=\"_blank\"\u003e \u003cbutton class=\"download-btn\"\u003eFiber Performance Chart\u003c\/button\u003e \u003c\/a\u003e \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0079\/8874\/0186\/files\/OCC-Fiber_Optic_Field_Testing_Guidelines_Rev_A-1.pdf?1613\" target=\"_blank\"\u003e \u003cbutton class=\"download-btn\"\u003eFiber Optic Cable Field Testing Guidelines\u003c\/button\u003e \u003c\/a\u003e \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0079\/8874\/0186\/files\/OCC-Installation-Aerial_Lashing_Guidelines_Rev_A-1.pdf?1613\" target=\"_blank\"\u003e \u003cbutton class=\"download-btn\"\u003eFiber Optic Cable Aerial Lashing Guidelines\u003c\/button\u003e \u003c\/a\u003e \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0079\/8874\/0186\/files\/OCC-Installation-Direct_Burial_Guidelines_Rev_A-1.pdf?1613\" target=\"_blank\"\u003e \u003cbutton class=\"download-btn\"\u003eFiber Optic Cable Direct Burial Guidelines\u003c\/button\u003e \u003c\/a\u003e \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0079\/8874\/0186\/files\/OCC-Installation-General_Guidelines_Rev_B-1.pdf?1613\" target=\"_blank\"\u003e \u003cbutton class=\"download-btn\"\u003eFiber Optic Cable General Guidelines\u003c\/button\u003e \u003c\/a\u003e \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0079\/8874\/0186\/files\/OCC-Installation-Conduit_Guidelines_Rev_A-1.pdf?1613\" target=\"_blank\"\u003e \u003cbutton class=\"download-btn\"\u003eFiber Optic Cable Conduit Guidelines\u003c\/button\u003e \u003c\/a\u003e \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0079\/8874\/0186\/files\/OCC-Storage_Handling_Rev_B-1.pdf?1613\" target=\"_blank\"\u003e \u003cbutton class=\"download-btn\"\u003eFiber Optic Cable Storage and Handling Guidelines\u003c\/button\u003e \u003c\/a\u003e \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0079\/8874\/0186\/files\/OCC-Interlock_Armor_CST_Cable_Grip_Installation_Procedure_Rev._7-1.pdf?1613\" target=\"_blank\"\u003e \u003cbutton class=\"download-btn\"\u003eILA and CST Cables Pulling Grip Installation Procedure\u003c\/button\u003e \u003c\/a\u003e\u003c\/p\u003e","brand":"OCC","offers":[{"title":"2 Strand","offer_id":31724673040445,"sku":"DX002DALE9QRI2","price":0.0,"currency_code":"USD","in_stock":true},{"title":"6 Strand","offer_id":31724673073213,"sku":"DX006DALE9QRI2","price":0.0,"currency_code":"USD","in_stock":true},{"title":"12 Strand","offer_id":31724673105981,"sku":"DX012DALE9QRI2","price":0.0,"currency_code":"USD","in_stock":true},{"title":"24 Strand","offer_id":31724673138749,"sku":"DX024DALE9QRI2","price":0.0,"currency_code":"USD","in_stock":true},{"title":"48 Strand","offer_id":31724673171517,"sku":"DX048DALE9QRI2","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0252\/1897\/3741\/products\/02Strand-10G_99d5754a-6dd0-48a6-bc81-b4f8177714cc.png?v=1567190773"},{"product_id":"direct-burial-fiber-optic-cable-2-strand-single-mode-9125-outdoor-polyethylene","title":"Direct Burial Polyethylene Bend Tolerant Fiber Optic Cable, Single Mode, Outdoor","description":"\u003cp\u003e\u003cimg height=\"65px\" width=\"115px\" class=\"bulleticons\" alt=\"Made in USA\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0252\/1897\/3741\/files\/Made_In_USA.png?2208\"\u003e \u003cmeta charset=\"utf-8\"\u003e\u003c\/p\u003e\n\u003ch3\u003e(We do not offer credits or returns for this item.)\u003c\/h3\u003e\n\u003ch3\u003eThis fiber cable is priced per foot and may include a minimum order length.\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eIf you would like to inquire about our custom fiber cable options such as terminated ends, pulleyes, and custom cut lengths, please call or email us.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003ci\u003ePlease call for shipping quote\u003c\/i\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch4\u003eDescription\u003c\/h4\u003e\n\u003ch2\u003eSingle Mode, 9\/125 OS2, Corrugated Steel Tape Armored Bend Tolerant Distribution Cable, Direct Burial, Outdoor\u003c\/h2\u003e\n\u003cp\u003eDirect burial armor fiber optic cables are ideal for installations that require a rugged armored fiber cable to be buried directly in the ground or for installation in conduit where rodents are still able to get inside. The corrugated steel tape has excellent water blocking abilities, providing a protective barrier between the fiber cable and the elements surrounding it. With an operating temperature range of between -40ºC and 85ºC, you can be sure that the armored direct burial fiber cable will be well protected in harsh conditions.\u003c\/p\u003e\n\u003cp\u003eThe outdoor armored fiber cable uses tight buffered inner fibers, allowing the technician to perform direct field terminations with standard fiber connectors. This helps save time and money and offers a huge benefit over using a loose tube fiber cable. The versatility of this armored direct burial fiber cable is nearly endless!\u003c\/p\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eIdeal for installation where direct burial or rodent protection is required\u003c\/li\u003e\n\u003cli\u003eIdeal for installations requiring an extremely rugged and reliable cable design where maximum mechanical and environmental protection are necessary\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eCleaning your fiber connector end faces and components regularly is crucial for avoiding a total network failure. Ensure your optical fiber system is working properly and prevent major network issues with \u003ca alt=\"Fiber Cleaning Kits\" href=\"https:\/\/www.primuscable.com\/collections\/fiber-cleaning-kit\" target=\"_blank\"\u003e\u003cstrong\u003e fiber cleaning kits,\u003c\/strong\u003e\u003c\/a\u003e \u003ca alt=\"Fiber Cleaning Pens\" href=\"https:\/\/www.primuscable.com\/collections\/fiber-cleaning-pens\" target=\"_blank\"\u003e\u003cstrong\u003e pens,\u003c\/strong\u003e\u003c\/a\u003e\u003ca alt=\"Fiber Cleaning Fluids\" href=\"https:\/\/www.primuscable.com\/collections\/fiber-cleaning-fluids\" target=\"_blank\"\u003e\u003cstrong\u003e fluids,\u003c\/strong\u003e\u003c\/a\u003e and \u003ca alt=\"Fiber Cleaning Wipes\" href=\"https:\/\/www.primuscable.com\/collections\/fiber-cleaning-wipes\" target=\"_blank\"\u003e\u003cstrong\u003ewipes.\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003ch4\u003eFeatures\u003c\/h4\u003e\n\u003ch3\u003e\u003cspan style=\"text-decoration: underline;\"\u003eFeatures\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eHigh-performance components and construction\u003c\/li\u003e\n\u003cli\u003eBend tolerant construction\u003c\/li\u003e\n\u003cli\u003eThe steel-armor is easily removed with an internal ripcord, leaving a fully functional intact D-Series Distribution inner cable with original cable marking for identification\u003c\/li\u003e\n\u003cli\u003eIdeal for use in point-to-point runs in between buildings\u003c\/li\u003e\n\u003cli\u003eInner cable materials are indoor\/outdoor: UV, water and fungus resistant\u003c\/li\u003e\n\u003cli\u003ePolyethylene (A) outer jacket is UV, water and fungus resistant: ideal for outdoor installations\u003c\/li\u003e\n\u003cli\u003eWide operating temperature range of -40°C to + 85°C\u003c\/li\u003e\n\u003cli\u003eHigh-performance 900µm tight-buffered coating on each optical fiber for environmental and mechanical protection 2 to 144 fibers\u003c\/li\u003e\n\u003cli\u003e900µm buffer eliminates the need for costly and time-consuming installation of fanout kits or pigtail splices because connectors terminate directly to the fiber\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eStandards\u003c\/h3\u003e\n\u003cp\u003eOCC CST armored tight-buffered fiber optic cables meet the functional requirements of the following standards:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eICEA-S-104-696\u003c\/li\u003e\n\u003cli\u003eTIA-568\u003c\/li\u003e\n\u003cli\u003eTIA-598\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eSpecifications\u003c\/h4\u003e\n\u003ch3\u003eCharacteristics\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eOperating Temp: -40°C to +85°C\u003c\/li\u003e\n\u003cli\u003eStorage Temp: -55°C to +85°C\u003c\/li\u003e\n\u003cli\u003eInstall Temp: -10°C to +60°C\u003c\/li\u003e\n\u003cli\u003eCrush Resist: 440 N\/cm (EIA-TIA-455-25A)\u003c\/li\u003e\n\u003cli\u003eImpact Resist: 20 impacts (EIA-TIA-455-25A)\u003c\/li\u003e\n\u003cli\u003eFlex Resist: 25 cycles\u003c\/li\u003e\n\u003cli\u003eJacket Type: D Inner, A Outer\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0252\/1897\/3741\/files\/SpecSheet_DX006DSLX9KAA2_1.pdf?v=1689982759\" target=\"_blank\"\u003e \u003cbutton class=\"download-btn\"\u003eSpec Sheet\u003c\/button\u003e \u003c\/a\u003e\u003c\/p\u003e\n\u003ch4\u003eAdditional Information\u003c\/h4\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0079\/8874\/0186\/files\/OCC-Ultra-Fox-perf_chart-1.pdf?1510\" target=\"_blank\"\u003e \u003cbutton class=\"download-btn\"\u003eFiber Performance Chart\u003c\/button\u003e \u003c\/a\u003e \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0079\/8874\/0186\/files\/OCC-Fiber_Optic_Field_Testing_Guidelines_Rev_A-1.pdf?1613\" target=\"_blank\"\u003e \u003cbutton class=\"download-btn\"\u003eFiber Optic Cable Field Testing Guidelines\u003c\/button\u003e \u003c\/a\u003e \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0079\/8874\/0186\/files\/OCC-Installation-Aerial_Lashing_Guidelines_Rev_A-1.pdf?1613\" target=\"_blank\"\u003e \u003cbutton class=\"download-btn\"\u003eFiber Optic Cable Aerial Lashing Guidelines\u003c\/button\u003e \u003c\/a\u003e \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0079\/8874\/0186\/files\/OCC-Installation-Direct_Burial_Guidelines_Rev_A-1.pdf?1613\" target=\"_blank\"\u003e \u003cbutton class=\"download-btn\"\u003eFiber Optic Cable Direct Burial Guidelines\u003c\/button\u003e \u003c\/a\u003e \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0079\/8874\/0186\/files\/OCC-Installation-General_Guidelines_Rev_B-1.pdf?1613\" target=\"_blank\"\u003e \u003cbutton class=\"download-btn\"\u003eFiber Optic Cable General Guidelines\u003c\/button\u003e \u003c\/a\u003e \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0079\/8874\/0186\/files\/OCC-Installation-Conduit_Guidelines_Rev_A-1.pdf?1613\" target=\"_blank\"\u003e \u003cbutton class=\"download-btn\"\u003eFiber Optic Cable Conduit Guidelines\u003c\/button\u003e \u003c\/a\u003e \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0079\/8874\/0186\/files\/OCC-Storage_Handling_Rev_B-1.pdf?1613\" target=\"_blank\"\u003e \u003cbutton class=\"download-btn\"\u003eFiber Optic Cable Storage and Handling Guidelines\u003c\/button\u003e \u003c\/a\u003e \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0079\/8874\/0186\/files\/OCC-Interlock_Armor_CST_Cable_Grip_Installation_Procedure_Rev._7-1.pdf?1613\" target=\"_blank\"\u003e \u003cbutton class=\"download-btn\"\u003eILA and CST Cables Pulling Grip Installation Procedure\u003c\/button\u003e \u003c\/a\u003e\u003c\/p\u003e","brand":"OCC","offers":[{"title":"2 Strand","offer_id":31710641881149,"sku":"DX002DSLA9KAA2","price":0.0,"currency_code":"USD","in_stock":true},{"title":"6 Strand","offer_id":31710641913917,"sku":"DX006DSLA9KAA2","price":1.88,"currency_code":"USD","in_stock":true},{"title":"12 Strand","offer_id":31710641946685,"sku":"DX012DSLA9KAA2","price":2.34,"currency_code":"USD","in_stock":true},{"title":"24 Strand","offer_id":31710641979453,"sku":"DX024DSLA9KAA2","price":0.0,"currency_code":"USD","in_stock":true},{"title":"48 Strand","offer_id":31710642012221,"sku":"DX048DSLA9KAA2","price":0.0,"currency_code":"USD","in_stock":true},{"title":"72 Strand","offer_id":31710642044989,"sku":"DX072DSLA9KAA2","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0252\/1897\/3741\/products\/002.png?v=1567190797"},{"product_id":"direct-burial-fiber-optic-cable-2-strand-multimode-62-5125-om1-outdoor-polyethylene","title":"Direct Burial Polyethylene Fiber Optic Cable, Multimode OM1, Outdoor","description":"\u003cp\u003e\u003cimg height=\"65px\" width=\"115px\" class=\"bulleticons\" alt=\"Made in USA\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0252\/1897\/3741\/files\/Made_In_USA.png?2208\"\u003e \u003cmeta charset=\"utf-8\"\u003e\u003c\/p\u003e\n\u003ch3\u003e(We do not offer credits or returns for this item.)\u003c\/h3\u003e\n\u003ch3\u003eThis fiber cable is priced per foot and may include a minimum order length.\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eIf you would like to inquire about our custom fiber cable options such as terminated ends, pulleyes, and custom cut lengths, please call or email us.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003ci\u003ePlease call for shipping quote\u003c\/i\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch4\u003eDescription\u003c\/h4\u003e\n\u003ch2\u003eMultimode, 62.5\/125 OM1, Corrugated Steel Tape Armored Distribution Cable, Direct Burial, Outdoor\u003c\/h2\u003e\n\u003cp\u003eDirect burial armor fiber optic cables are ideal for installations that require a rugged armored fiber cable to be buried directly in the ground or for installation in conduit where rodents are still able to get inside. The corrugated steel tape has excellent water blocking abilities, providing a protective barrier between the fiber cable and the elements surrounding it. With an operating temperature range of between -40ºC and 85ºC, you can be sure that the armored direct burial fiber cable will be well protected in harsh conditions.\u003c\/p\u003e\n\u003cp\u003eThe outdoor armored fiber cable uses tight buffered inner fibers, allowing the technician to perform direct field terminations with standard fiber connectors. This helps save time and money and offers a huge benefit over using a loose tube fiber cable. The inner cable utilizes a distribution series riser design, so the cable can even be run indoors if the armoring is removed. The versatility of this armored direct burial fiber cable is nearly endless!\u003c\/p\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eIdeal for installation where direct burial or rodent protection is required\u003c\/li\u003e\n\u003cli\u003eOFCR rated to allow entry into riser spaces in unlimited lengths\u003c\/li\u003e\n\u003cli\u003eIdeal for installations requiring an extremely rugged and reliable cable design where maximum mechanical and environmental protection are necessary\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eCleaning your fiber connector end faces and components regularly is crucial for avoiding a total network failure. Ensure your optical fiber system is working properly and prevent major network issues with \u003ca alt=\"Fiber Cleaning Kits\" href=\"https:\/\/www.primuscable.com\/collections\/fiber-cleaning-kit\" target=\"_blank\"\u003e\u003cstrong\u003e fiber cleaning kits,\u003c\/strong\u003e\u003c\/a\u003e \u003ca alt=\"Fiber Cleaning Pens\" href=\"https:\/\/www.primuscable.com\/collections\/fiber-cleaning-pens\" target=\"_blank\"\u003e\u003cstrong\u003e pens,\u003c\/strong\u003e\u003c\/a\u003e\u003ca alt=\"Fiber Cleaning Fluids\" href=\"https:\/\/www.primuscable.com\/collections\/fiber-cleaning-fluids\" target=\"_blank\"\u003e\u003cstrong\u003e fluids,\u003c\/strong\u003e\u003c\/a\u003e and \u003ca alt=\"Fiber Cleaning Wipes\" href=\"https:\/\/www.primuscable.com\/collections\/fiber-cleaning-wipes\" target=\"_blank\"\u003e\u003cstrong\u003ewipes.\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003ch4\u003eFeatures\u003c\/h4\u003e\n\u003ch3\u003e\u003cspan style=\"text-decoration: underline;\"\u003eFeatures\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eHigh-performance components and construction\u003c\/li\u003e\n\u003cli\u003eThe steel-armor is easily removed with an internal ripcord, leaving a fully functional intact D-Series Distribution riser-rated inner cable with original cable marking for identification\u003c\/li\u003e\n\u003cli\u003eIdeal for use in point-to-point runs in between buildings\u003c\/li\u003e\n\u003cli\u003eInner cable materials are Indoor\/Outdoor: UV, water and fungus resistant\u003c\/li\u003e\n\u003cli\u003ePolyethylene (A) outer jacket is UV, water and fungus resistant: ideal for outdoor installations\u003c\/li\u003e\n\u003cli\u003eWide operating temperature range of -40°C to + 85°C\u003c\/li\u003e\n\u003cli\u003eHigh-performance 900µm tight-buffered coating on each optical fiber for environmental and mechanical protection 2 to 144 fibers\u003c\/li\u003e\n\u003cli\u003e900µm buffer eliminates the need for costly and time-consuming installation of fanout kits or pigtail splices because connectors terminate directly to the fiber\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eStandards\u003c\/h3\u003e\n\u003cp\u003eOCC CST armored tight-buffered fiber optic cables meet the functional requirements of the following standards:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eICEA-S-104-696\u003c\/li\u003e\n\u003cli\u003eTIA-568\u003c\/li\u003e\n\u003cli\u003eTIA-598\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eSpecifications\u003c\/h4\u003e\n\u003ch3\u003eCharacteristics\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eOperating Temp: -40°C to +85°C\u003c\/li\u003e\n\u003cli\u003eStorage Temp: -55°C to +85°C\u003c\/li\u003e\n\u003cli\u003eInstall Temp: -10°C to +60°C\u003c\/li\u003e\n\u003cli\u003eCrush Resist: 440 N\/cm (EIA-TIA-455-25A)\u003c\/li\u003e\n\u003cli\u003eImpact Resist: 20 impacts (EIA-TIA-455-25A)\u003c\/li\u003e\n\u003cli\u003eFlex Resist: 25 cycles\u003c\/li\u003e\n\u003cli\u003eJacket Type: D Inner, A Outer\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0079\/8874\/0186\/files\/OCC-Direct-Burial-Armored-Fiber.pdf?1614\" target=\"_blank\"\u003e \u003cbutton class=\"download-btn\"\u003eFiber Specifications Chart\u003c\/button\u003e \u003c\/a\u003e\u003c\/p\u003e\n\u003ch4\u003eAdditional Information\u003c\/h4\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0079\/8874\/0186\/files\/OCC-Ultra-Fox-perf_chart-1.pdf?1510\" target=\"_blank\"\u003e \u003cbutton class=\"download-btn\"\u003eFiber Performance Chart\u003c\/button\u003e \u003c\/a\u003e \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0079\/8874\/0186\/files\/OCC-Fiber_Optic_Field_Testing_Guidelines_Rev_A-1.pdf?1613\" target=\"_blank\"\u003e \u003cbutton class=\"download-btn\"\u003eFiber Optic Cable Field Testing Guidelines\u003c\/button\u003e \u003c\/a\u003e \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0079\/8874\/0186\/files\/OCC-Installation-Aerial_Lashing_Guidelines_Rev_A-1.pdf?1613\" target=\"_blank\"\u003e \u003cbutton class=\"download-btn\"\u003eFiber Optic Cable Aerial Lashing Guidelines\u003c\/button\u003e \u003c\/a\u003e \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0079\/8874\/0186\/files\/OCC-Installation-Direct_Burial_Guidelines_Rev_A-1.pdf?1613\" target=\"_blank\"\u003e \u003cbutton class=\"download-btn\"\u003eFiber Optic Cable Direct Burial Guidelines\u003c\/button\u003e \u003c\/a\u003e \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0079\/8874\/0186\/files\/OCC-Installation-General_Guidelines_Rev_B-1.pdf?1613\" target=\"_blank\"\u003e \u003cbutton class=\"download-btn\"\u003eFiber Optic Cable General Guidelines\u003c\/button\u003e \u003c\/a\u003e \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0079\/8874\/0186\/files\/OCC-Installation-Conduit_Guidelines_Rev_A-1.pdf?1613\" target=\"_blank\"\u003e \u003cbutton class=\"download-btn\"\u003eFiber Optic Cable Conduit Guidelines\u003c\/button\u003e \u003c\/a\u003e \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0079\/8874\/0186\/files\/OCC-Storage_Handling_Rev_B-1.pdf?1613\" target=\"_blank\"\u003e \u003cbutton class=\"download-btn\"\u003eFiber Optic Cable Storage and Handling Guidelines\u003c\/button\u003e \u003c\/a\u003e \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0079\/8874\/0186\/files\/OCC-Interlock_Armor_CST_Cable_Grip_Installation_Procedure_Rev._7-1.pdf?1613\" target=\"_blank\"\u003e \u003cbutton class=\"download-btn\"\u003e ILA and CST Cables Pulling Grip Installation Procedure\u003c\/button\u003e \u003c\/a\u003e\u003c\/p\u003e","brand":"OCC","offers":[{"title":"2 Strand","offer_id":31730961285181,"sku":"DX002DWLS9KAA2","price":1.89,"currency_code":"USD","in_stock":true},{"title":"6 Strand","offer_id":31730961317949,"sku":"DX006DWLS9KAA2","price":1.99,"currency_code":"USD","in_stock":true},{"title":"12 Strand","offer_id":31730961350717,"sku":"DX012DWLS9KAA2","price":2.35,"currency_code":"USD","in_stock":true},{"title":"24 Strand","offer_id":31730961383485,"sku":"DX024DWLS9KAA2","price":0.0,"currency_code":"USD","in_stock":true},{"title":"48 Strand","offer_id":31730961416253,"sku":"DX048DWLS9KAA2","price":0.0,"currency_code":"USD","in_stock":true},{"title":"72 Strand","offer_id":31730961449021,"sku":"DX072DWLS9KAA2","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0252\/1897\/3741\/products\/002_e45f850a-bf0a-4c08-a5b7-17899671e27d.png?v=1567190800"},{"product_id":"direct-burial-fiber-optic-cable-2-strand-multimode-50125-10-gig-om3-outdoor-polyethylene","title":"Direct Burial Polyethylene Fiber Optic Cable, Multimode 10 Gig OM3, Outdoor","description":"\u003cp\u003e\u003cimg height=\"65px\" width=\"115px\" class=\"bulleticons\" alt=\"Made in USA\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0252\/1897\/3741\/files\/Made_In_USA.png?2208\"\u003e \u003cmeta charset=\"utf-8\"\u003e\u003c\/p\u003e\n\u003ch3\u003e(We do not offer credits or returns for this item.)\u003c\/h3\u003e\n\u003ch3\u003eThis fiber cable is priced per foot and may include a minimum order length.\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eIf you would like to inquire about our custom fiber cable options such as terminated ends, pulleyes, and custom cut lengths, please call or email us.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003ci\u003ePlease call for shipping quote\u003c\/i\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch4\u003eDescription\u003c\/h4\u003e\n\u003ch2\u003eMultimode, 50\/125 OM3, Corrugated Steel Tape Armored Distribution Cable, Direct Burial, Outdoor\u003c\/h2\u003e\n\u003cp\u003eDirect burial armor fiber optic cables are ideal for installations that require a rugged armored fiber cable to be buried directly in the ground or for installation in conduit where rodents are still able to get inside. The corrugated steel tape has excellent water blocking abilities, providing a protective barrier between the fiber cable and the elements surrounding it. With an operating temperature range of between -40ºC and 85ºC, you can be sure that the armored direct burial fiber cable will be well protected in harsh conditions.\u003c\/p\u003e\n\u003cp\u003eThe outdoor armored fiber cable uses tight buffered inner fibers, allowing the technician to perform direct field terminations with standard fiber connectors. This helps save time and money and offers a huge benefit over using a loose tube fiber cable. The inner cable utilizes a distribution series riser design, so the cable can even be run indoors if the armoring is removed. The versatility of this armored direct burial fiber cable is nearly endless!\u003c\/p\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eIdeal for installation where direct burial or rodent protection is required\u003c\/li\u003e\n\u003cli\u003eOFCR rated to allow entry into riser spaces in unlimited lengths\u003c\/li\u003e\n\u003cli\u003eIdeal for installations requiring an extremely rugged and reliable cable design where maximum mechanical and environmental protection are necessary\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eCleaning your fiber connector end faces and components regularly is crucial for avoiding a total network failure. Ensure your optical fiber system is working properly and prevent major network issues with \u003ca alt=\"Fiber Cleaning Kits\" href=\"https:\/\/www.primuscable.com\/collections\/fiber-cleaning-kit\" target=\"_blank\"\u003e\u003cstrong\u003e fiber cleaning kits,\u003c\/strong\u003e\u003c\/a\u003e \u003ca alt=\"Fiber Cleaning Pens\" href=\"https:\/\/www.primuscable.com\/collections\/fiber-cleaning-pens\" target=\"_blank\"\u003e\u003cstrong\u003e pens,\u003c\/strong\u003e\u003c\/a\u003e\u003ca alt=\"Fiber Cleaning Fluids\" href=\"https:\/\/www.primuscable.com\/collections\/fiber-cleaning-fluids\" target=\"_blank\"\u003e\u003cstrong\u003e fluids,\u003c\/strong\u003e\u003c\/a\u003e and \u003ca alt=\"Fiber Cleaning Wipes\" href=\"https:\/\/www.primuscable.com\/collections\/fiber-cleaning-wipes\" target=\"_blank\"\u003e\u003cstrong\u003ewipes.\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003ch4\u003eFeatures\u003c\/h4\u003e\n\u003ch3\u003e\u003cspan style=\"text-decoration: underline;\"\u003eFeatures\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eHigh-performance components and construction\u003c\/li\u003e\n\u003cli\u003eThe steel-armor is easily removed with an internal ripcord, leaving a fully functional intact D-Series Distribution riser-rated inner cable with original cable marking for identification\u003c\/li\u003e\n\u003cli\u003eIdeal for use in point-to-point runs in between buildings\u003c\/li\u003e\n\u003cli\u003eInner cable materials are Indoor\/Outdoor: UV, water and fungus resistant\u003c\/li\u003e\n\u003cli\u003ePolyethylene (A) outer jacket is UV, water and fungus resistant: ideal for outdoor installations\u003c\/li\u003e\n\u003cli\u003eWide operating temperature range of -40°C to + 85°C\u003c\/li\u003e\n\u003cli\u003eHigh-performance 900µm tight-buffered coating on each optical fiber for environmental and mechanical protection 2 to 144 fibers\u003c\/li\u003e\n\u003cli\u003e900µm buffer eliminates the need for costly and time-consuming installation of fanout kits or pigtail splices because connectors terminate directly to the fiber\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eStandards\u003c\/h3\u003e\n\u003cp\u003eOCC CST armored tight-buffered fiber optic cables meet the functional requirements of the following standards:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eICEA-S-104-696\u003c\/li\u003e\n\u003cli\u003eTIA-568\u003c\/li\u003e\n\u003cli\u003eTIA-598\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eSpecifications\u003c\/h4\u003e\n\u003ch3\u003eCharacteristics\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eOperating Temp: -40°C to +85°C\u003c\/li\u003e\n\u003cli\u003eStorage Temp: -55°C to +85°C\u003c\/li\u003e\n\u003cli\u003eInstall Temp: -10°C to +60°C\u003c\/li\u003e\n\u003cli\u003eCrush Resist: 440 N\/cm (EIA-TIA-455-25A)\u003c\/li\u003e\n\u003cli\u003eImpact Resist: 20 impacts (EIA-TIA-455-25A)\u003c\/li\u003e\n\u003cli\u003eFlex Resist: 25 cycles\u003c\/li\u003e\n\u003cli\u003eJacket Type: D Inner, A Outer\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0079\/8874\/0186\/files\/OCC-Direct-Burial-Armored-Fiber.pdf?1614\" target=\"_blank\"\u003e \u003cbutton class=\"download-btn\"\u003eFiber Specifications Chart\u003c\/button\u003e \u003c\/a\u003e\u003c\/p\u003e\n\u003ch4\u003eAdditional Information\u003c\/h4\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0079\/8874\/0186\/files\/OCC-Ultra-Fox-perf_chart-1.pdf?1510\" target=\"_blank\"\u003e \u003cbutton class=\"download-btn\"\u003eFiber Performance Chart\u003c\/button\u003e \u003c\/a\u003e \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0079\/8874\/0186\/files\/OCC-Fiber_Optic_Field_Testing_Guidelines_Rev_A-1.pdf?1613\" target=\"_blank\"\u003e \u003cbutton class=\"download-btn\"\u003eFiber Optic Cable Field Testing Guidelines\u003c\/button\u003e \u003c\/a\u003e \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0079\/8874\/0186\/files\/OCC-Installation-Aerial_Lashing_Guidelines_Rev_A-1.pdf?1613\" target=\"_blank\"\u003e \u003cbutton class=\"download-btn\"\u003eFiber Optic Cable Aerial Lashing Guidelines\u003c\/button\u003e \u003c\/a\u003e \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0079\/8874\/0186\/files\/OCC-Installation-Direct_Burial_Guidelines_Rev_A-1.pdf?1613\" target=\"_blank\"\u003e \u003cbutton class=\"download-btn\"\u003eFiber Optic Cable Direct Burial Guidelines\u003c\/button\u003e \u003c\/a\u003e \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0079\/8874\/0186\/files\/OCC-Installation-General_Guidelines_Rev_B-1.pdf?1613\" target=\"_blank\"\u003e \u003cbutton class=\"download-btn\"\u003eFiber Optic Cable General Guidelines\u003c\/button\u003e \u003c\/a\u003e \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0079\/8874\/0186\/files\/OCC-Installation-Conduit_Guidelines_Rev_A-1.pdf?1613\" target=\"_blank\"\u003e \u003cbutton class=\"download-btn\"\u003eFiber Optic Cable Conduit Guidelines\u003c\/button\u003e \u003c\/a\u003e \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0079\/8874\/0186\/files\/OCC-Storage_Handling_Rev_B-1.pdf?1613\" target=\"_blank\"\u003e \u003cbutton class=\"download-btn\"\u003eFiber Optic Cable Storage and Handling Guidelines\u003c\/button\u003e \u003c\/a\u003e \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0079\/8874\/0186\/files\/OCC-Interlock_Armor_CST_Cable_Grip_Installation_Procedure_Rev._7-1.pdf?1613\" target=\"_blank\"\u003e \u003cbutton class=\"download-btn\"\u003eILA and CST Cables Pulling Grip Installation Procedure\u003c\/button\u003e \u003c\/a\u003e\u003c\/p\u003e","brand":"OCC","offers":[{"title":"2 Strand","offer_id":31731248496701,"sku":"DX002DALT9KAA2","price":0.0,"currency_code":"USD","in_stock":true},{"title":"6 Strand","offer_id":31731248529469,"sku":"DX006DALT9KAA2","price":0.0,"currency_code":"USD","in_stock":true},{"title":"12 Strand","offer_id":31731248562237,"sku":"DX012DALT9KAA2","price":0.0,"currency_code":"USD","in_stock":true},{"title":"24 Strand","offer_id":31731248595005,"sku":"DX024DALT9KAA2","price":0.0,"currency_code":"USD","in_stock":true},{"title":"48 Strand","offer_id":31731248627773,"sku":"DX048DALT9KAA2","price":0.0,"currency_code":"USD","in_stock":true},{"title":"72 Strand","offer_id":31731248660541,"sku":"DX072DALT9KAA2","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0252\/1897\/3741\/products\/002_23b60335-d575-4337-aa97-7521f4e8df36.png?v=1567190801"},{"product_id":"direct-burial-fiber-optic-cable-2-strand-multimode-50125-10-gig-om4-outdoor-polyethylene","title":"Direct Burial Distribution Fiber Optic Cable, Outdoor, Riser OFCR, Multimode OM4","description":"\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0252\/1897\/3741\/files\/Made_In_USA.png?2208\" alt=\"Made in USA\" class=\"bulleticons\" width=\"115px\" height=\"65px\"\u003e \u003cmeta charset=\"utf-8\"\u003e\u003c\/p\u003e\n\u003ch3\u003e(We do not offer credits or returns for this item.)\u003c\/h3\u003e\n\u003ch3\u003eThis fiber cable is priced per foot and may include a minimum order length.\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eIf you would like to inquire about our custom fiber cable options such as terminated ends, pulleyes, and custom cut lengths, please call or email us.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003ci\u003ePlease call for shipping quote\u003c\/i\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch4\u003eDescription\u003c\/h4\u003e\n\u003ch2\u003eMultimode, 50\/125 OM4, Corrugated Steel Tape Armored Distribution Cable, Direct Burial, Riser OFCR, Outdoor\u003c\/h2\u003e\n\u003cp\u003eDirect burial armor fiber optic cables are ideal for installations that require a rugged armored fiber cable to be buried directly in the ground or for installation in conduit where rodents are still able to get inside. The corrugated steel tape has excellent water blocking abilities, providing a protective barrier between the fiber cable and the elements surrounding it. With an operating temperature range of between -40ºC and 85ºC, you can be sure that the armored direct burial fiber cable will be well protected in harsh conditions.\u003c\/p\u003e\n\u003cp\u003eThe outdoor armored fiber cable uses tight buffered inner fibers, allowing the technician to perform direct field terminations with standard fiber connectors. This helps save time and money and offers a huge benefit over using a loose tube fiber cable. The inner cable utilizes a distribution series riser design, so the cable can even be run indoors if the armoring is removed. The versatility of this armored direct burial fiber cable is nearly endless!\u003c\/p\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eIdeal for installation where direct burial or rodent protection is required\u003c\/li\u003e\n\u003cli\u003eOFCR rated to allow entry into riser spaces in unlimited lengths\u003c\/li\u003e\n\u003cli\u003eIdeal for installations requiring an extremely rugged and reliable cable design where maximum mechanical and environmental protection are necessary\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eCleaning your fiber connector end faces and components regularly is crucial for avoiding a total network failure. Ensure your optical fiber system is working properly and prevent major network issues with \u003ca href=\"https:\/\/www.primuscable.com\/collections\/fiber-cleaning-kit\" alt=\"Fiber Cleaning Kits\" target=\"_blank\"\u003e\u003cstrong\u003e fiber cleaning kits,\u003c\/strong\u003e\u003c\/a\u003e \u003ca href=\"https:\/\/www.primuscable.com\/collections\/fiber-cleaning-pens\" alt=\"Fiber Cleaning Pens\" target=\"_blank\"\u003e\u003cstrong\u003e pens,\u003c\/strong\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/www.primuscable.com\/collections\/fiber-cleaning-fluids\" alt=\"Fiber Cleaning Fluids\" target=\"_blank\"\u003e\u003cstrong\u003e fluids,\u003c\/strong\u003e\u003c\/a\u003e and \u003ca href=\"https:\/\/www.primuscable.com\/collections\/fiber-cleaning-wipes\" alt=\"Fiber Cleaning Wipes\" target=\"_blank\"\u003e\u003cstrong\u003ewipes.\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003ch4\u003eFeatures\u003c\/h4\u003e\n\u003ch3\u003e\u003cspan style=\"text-decoration: underline;\"\u003eFeatures\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eHigh-performance components and construction\u003c\/li\u003e\n\u003cli\u003eThe steel-armor is easily removed with an internal ripcord, leaving a fully functional intact D-Series Distribution riser-rated inner cable with original cable marking for identification\u003c\/li\u003e\n\u003cli\u003eIdeal for use in point-to-point runs in between buildings\u003c\/li\u003e\n\u003cli\u003eInner cable materials are Indoor\/Outdoor: UV, water and fungus resistant\u003c\/li\u003e\n\u003cli\u003ePolyethylene (A) outer jacket is UV, water and fungus resistant: ideal for outdoor installations\u003c\/li\u003e\n\u003cli\u003eWide operating temperature range of -40°C to + 85°C\u003c\/li\u003e\n\u003cli\u003eHigh-performance 900µm tight-buffered coating on each optical fiber for environmental and mechanical protection 2 to 144 fibers\u003c\/li\u003e\n\u003cli\u003e900µm buffer eliminates the need for costly and time-consuming installation of fanout kits or pigtail splices because connectors terminate directly to the fiber\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eStandards\u003c\/h3\u003e\n\u003cp\u003eOCC CST armored tight-buffered fiber optic cables meet the functional requirements of the following standards:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eICEA-S-104-696\u003c\/li\u003e\n\u003cli\u003eTIA-568\u003c\/li\u003e\n\u003cli\u003eTIA-598\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eSpecifications\u003c\/h4\u003e\n\u003ch3\u003eCharacteristics\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eOperating Temp: -40°C to +85°C\u003c\/li\u003e\n\u003cli\u003eStorage Temp: -55°C to +85°C\u003c\/li\u003e\n\u003cli\u003eInstall Temp: -10°C to +60°C\u003c\/li\u003e\n\u003cli\u003eCrush Resist: 440 N\/cm (EIA-TIA-455-25A)\u003c\/li\u003e\n\u003cli\u003eImpact Resist: 20 impacts (EIA-TIA-455-25A)\u003c\/li\u003e\n\u003cli\u003eFlex Resist: 25 cycles\u003c\/li\u003e\n\u003cli\u003eJacket Type: D Inner, A Outer\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0079\/8874\/0186\/files\/OCC-Direct-Burial-Armored-Fiber.pdf?1614\" target=\"_blank\"\u003e \u003cbutton class=\"download-btn\"\u003eFiber Specifications Chart\u003c\/button\u003e \u003c\/a\u003e\u003c\/p\u003e\n\u003ch4\u003eAdditional Information\u003c\/h4\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0079\/8874\/0186\/files\/OCC-Ultra-Fox-perf_chart-1.pdf?1510\" target=\"_blank\"\u003e \u003cbutton class=\"download-btn\"\u003eFiber Performance Chart\u003c\/button\u003e \u003c\/a\u003e \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0079\/8874\/0186\/files\/OCC-Fiber_Optic_Field_Testing_Guidelines_Rev_A-1.pdf?1613\" target=\"_blank\"\u003e \u003cbutton class=\"download-btn\"\u003eFiber Optic Cable Field Testing Guidelines\u003c\/button\u003e \u003c\/a\u003e \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0079\/8874\/0186\/files\/OCC-Installation-Aerial_Lashing_Guidelines_Rev_A-1.pdf?1613\" target=\"_blank\"\u003e \u003cbutton class=\"download-btn\"\u003eFiber Optic Cable Aerial Lashing Guidelines\u003c\/button\u003e \u003c\/a\u003e \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0079\/8874\/0186\/files\/OCC-Installation-Direct_Burial_Guidelines_Rev_A-1.pdf?1613\" target=\"_blank\"\u003e \u003cbutton class=\"download-btn\"\u003eFiber Optic Cable Direct Burial Guidelines\u003c\/button\u003e \u003c\/a\u003e \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0079\/8874\/0186\/files\/OCC-Installation-General_Guidelines_Rev_B-1.pdf?1613\" target=\"_blank\"\u003e \u003cbutton class=\"download-btn\"\u003eFiber Optic Cable General Guidelines\u003c\/button\u003e \u003c\/a\u003e \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0079\/8874\/0186\/files\/OCC-Installation-Conduit_Guidelines_Rev_A-1.pdf?1613\" target=\"_blank\"\u003e \u003cbutton class=\"download-btn\"\u003eFiber Optic Cable Conduit Guidelines\u003c\/button\u003e \u003c\/a\u003e \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0079\/8874\/0186\/files\/OCC-Storage_Handling_Rev_B-1.pdf?1613\" target=\"_blank\"\u003e \u003cbutton class=\"download-btn\"\u003eFiber Optic Cable Storage and Handling Guidelines\u003c\/button\u003e \u003c\/a\u003e \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0079\/8874\/0186\/files\/OCC-Interlock_Armor_CST_Cable_Grip_Installation_Procedure_Rev._7-1.pdf?1613\" target=\"_blank\"\u003e \u003cbutton class=\"download-btn\"\u003eILA and CST Cables Pulling Grip Installation Procedure\u003c\/button\u003e \u003c\/a\u003e\u003c\/p\u003e","brand":"OCC","offers":[{"title":"2 Strand","offer_id":31710693785661,"sku":"DX002DALE9KAA2","price":0.0,"currency_code":"USD","in_stock":true},{"title":"6 Strand","offer_id":31710693818429,"sku":"DX006DALE9KAA2","price":0.0,"currency_code":"USD","in_stock":true},{"title":"12 Strand","offer_id":31710693851197,"sku":"DX012DALE9KAA2","price":0.0,"currency_code":"USD","in_stock":true},{"title":"24 Strand","offer_id":31710693883965,"sku":"DX024DALE9KAA2","price":0.0,"currency_code":"USD","in_stock":true},{"title":"48 Strand","offer_id":31710693916733,"sku":"DX048DALE9KAA2","price":0.0,"currency_code":"USD","in_stock":true},{"title":"72 Strand","offer_id":31710693949501,"sku":"DX072DALE9KAA2","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0252\/1897\/3741\/products\/002_aab8f1d9-bf9c-4916-91ac-4d65c63db552.png?v=1567190805"},{"product_id":"breakout-fiber-optic-cable-single-mode-9125-indooroutdoor-plenum","title":"Breakout Single Mode Plenum Fiber Optic Cable, Indoor\/Outdoor","description":"\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0252\/1897\/3741\/files\/Made_In_USA.png?2208\" alt=\"Made in USA\" width=\"115px\" height=\"65px\" style=\"background-color: #fff; border-radius: 10px; padding: 5px;\"\u003e \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0252\/1897\/3741\/files\/UL_LISTED_LOGO_US.png?2209\" alt=\"UL Listed\" width=\"75px\" height=\"65px\" style=\"background-color: #fff; border-radius: 10px; padding: 5px;\"\u003e \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0252\/1897\/3741\/files\/Bullets-_RoHS.jpg?2209\" alt=\"RoHS Compliant\" width=\"55px\" height=\"75px\" style=\"background-color: #fff; border-radius: 10px; padding: 5px;\"\u003e \u003cmeta charset=\"utf-8\"\u003e\u003c\/p\u003e\n\u003ch5\u003e(We do not offer credits or returns for this item.)\u003c\/h5\u003e\n\u003cp\u003e\u003cstrong\u003eThis fiber cable is priced per foot and may include a minimum order length.\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch5\u003eIf you would like to inquire about our custom fiber cable options such as terminated ends, pulleyes, and custom cut lengths, please call or email us.\u003c\/h5\u003e\n\u003cp\u003e\u003cstrong\u003ePlease call for shipping quote\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch4\u003eDescription\u003c\/h4\u003e\n\u003ch2\u003eBreakout Fiber Optic Cable, Single Mode, 9\/125, Indoor\/Outdoor, Plenum (OFNP)\u003c\/h2\u003e\n\u003cp\u003e\u003cmeta charset=\"utf-8\"\u003e\u003cspan\u003eIdeal for demanding installations, the Breakout Plenum OFNP Single Mode 9\/125 OS2 Fiber Cable offers rugged and reliable design for maximum mechanical and environmental protection. It's the easiest to install for direct termination of connectors to sub-units and panels\/equipment, providing additional strain relief for better connector retention. UL Listed per NEC sections 770.179(b) for use in ducts, plenums, and air-handling spaces.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eCleaning your fiber connector end faces and components regularly is crucial for avoiding a total network failure. Ensure your optical fiber system is working properly and prevent major network issues with \u003ca href=\"https:\/\/www.primuscable.com\/collections\/fiber-cleaning-kit\" alt=\"Fiber Cleaning Kits\" target=\"_blank\"\u003e\u003cstrong\u003e fiber cleaning kits,\u003c\/strong\u003e\u003c\/a\u003e \u003ca href=\"https:\/\/www.primuscable.com\/collections\/fiber-cleaning-pens\" alt=\"Fiber Cleaning Pens\" target=\"_blank\"\u003e\u003cstrong\u003e pens,\u003c\/strong\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/www.primuscable.com\/collections\/fiber-cleaning-fluids\" alt=\"Fiber Cleaning Fluids\" target=\"_blank\"\u003e\u003cstrong\u003e fluids,\u003c\/strong\u003e\u003c\/a\u003e and \u003ca href=\"https:\/\/www.primuscable.com\/collections\/fiber-cleaning-wipes\" alt=\"Fiber Cleaning Wipes\" target=\"_blank\"\u003e\u003cstrong\u003ewipes.\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003ch4\u003eFeatures\u003c\/h4\u003e\n\u003ch3\u003e\u003cspan style=\"text-decoration: underline;\"\u003eFeatures\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eHigh performance components and construction\u003c\/li\u003e\n\u003cli\u003eUL Listed in accordance with NEC sections 770.179(b) for use in ducts, plenums and air-handling spaces\u003c\/li\u003e\n\u003cli\u003eMost rugged and easy to install cable design for enterprise cabling applications\u003c\/li\u003e\n\u003cli\u003eCore-Locked™ outer jacket design for installation survivability, long-term, trouble free service\u003c\/li\u003e\n\u003cli\u003eIdeal for use in long, vertical installations\u003c\/li\u003e\n\u003cli\u003e2.0mm subcables can be direct-terminated with standard connectors (2.5mm and 2.9mm subcables also available)\u003c\/li\u003e\n\u003cli\u003eSubcabled fiber is environmentally and mechanically protected\u003c\/li\u003e\n\u003cli\u003eIdeal for use in point-to-point runs in adverse environments\u003c\/li\u003e\n\u003cli\u003eDirect termination to subcable provides additional strain relief for better connector retention during moves, adds, and changes\u003c\/li\u003e\n\u003cli\u003eDesign is ideal for direct pulling with mesh grips\u003c\/li\u003e\n\u003cli\u003eCable materials are indoor\/outdoor - UV, water and fungus resistant\u003c\/li\u003e\n\u003cli\u003eWide operating temperature range of -40ºC to +85ºC\u003c\/li\u003e\n\u003cli\u003eHigh performance 900 _m tight buffered coating on each optical fiber for environmental and mechanical protection\u003c\/li\u003e\n\u003cli\u003eInterlocking armor can be applied to cables as an alternative to conduit installation\u003c\/li\u003e\n\u003cli\u003e2 to 48 fibers\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eIdeal for installations requiring an extremely rugged and reliable cable design where maximum mechanical and environmental protection are necessary\u003c\/li\u003e\n\u003cli\u003eEasiest cable to install where direct termination of connectors to sub-units and direct run to panels and equipment is desired\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eCost Savings\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eDirect termination to subcable may eliminate the need for patch panels and patch cords and reduces connector loss\u003c\/li\u003e\n\u003cli\u003e\n\u003cmeta charset=\"utf-8\"\u003e \u003cspan\u003e900 um\u003c\/span\u003e buffer eliminates the need for costly and time-consuming installation of fanout kits or pigtail splices because connectors terminate directly to the fiber\u003c\/li\u003e\n\u003cli\u003eHigh crush resistance may eliminate the need for innerduct\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eStandards List\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eUL 1651\u003c\/li\u003e\n\u003cli\u003eANSI\/NFPA 262\u003c\/li\u003e\n\u003cli\u003eGR-409-CORE\u003c\/li\u003e\n\u003cli\u003eICEA-S-104-696\u003c\/li\u003e\n\u003cli\u003eICEA-S-83-596\u003c\/li\u003e\n\u003cli\u003eTIA-568\u003c\/li\u003e\n\u003cli\u003eTIA-598\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eSpecifications\u003c\/h4\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0079\/8874\/0186\/files\/OCC_Breakout_OFNP_Specs.pdf?3934\" target=\"_blank\"\u003e \u003cbutton class=\"download-btn\"\u003eSpec Sheet\u003c\/button\u003e \u003c\/a\u003e \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0079\/8874\/0186\/files\/OCC-Ultra-Fox-perf_chart-1.pdf?1946\" target=\"_blank\"\u003e \u003cbutton class=\"download-btn\"\u003eFiber Performance Chart\u003c\/button\u003e \u003c\/a\u003e \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0079\/8874\/0186\/files\/OCC-Mil-Tac_Installation-General_Guidelines_Rev_B-1.pdf?3926\" target=\"_blank\"\u003e \u003cbutton class=\"download-btn\"\u003eGeneral Guidelines\u003c\/button\u003e \u003c\/a\u003e \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0079\/8874\/0186\/files\/OCC-Mil-Tac_Fiber_Optic_Field_Testing_Guidelines_Rev_A-1.pdf?3926\" target=\"_blank\"\u003e \u003cbutton class=\"download-btn\"\u003eTesting Guidelines\u003c\/button\u003e \u003c\/a\u003e \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0079\/8874\/0186\/files\/OCC-Mil-Tac_Storage_Handling_Rev_B-1.pdf?3926\" target=\"_blank\"\u003e \u003cbutton class=\"download-btn\"\u003eStorage Handling\u003c\/button\u003e \u003c\/a\u003e \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0079\/8874\/0186\/files\/OCC_Recommended_Duct_Installation_Guideline_Rev_2-1.pdf?3933\" target=\"_blank\"\u003e \u003cbutton class=\"download-btn\"\u003eDuct Install Guidelines\u003c\/button\u003e \u003c\/a\u003e \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0079\/8874\/0186\/files\/OCC_Installation-Cable_Tray_Vertical_Rise_Guidelines_Rev_A-1.pdf?3933\" target=\"_blank\"\u003e \u003cbutton class=\"download-btn\"\u003eCable Tray Guidelines\u003c\/button\u003e \u003c\/a\u003e \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0079\/8874\/0186\/files\/OCC_Breakout_and_Subgrouping_Cable_Pulling_Grip_Installation_Procedure_Rev._1-1.pdf?3933\" target=\"_blank\"\u003e \u003cbutton class=\"download-btn\"\u003eCable Pulling Installation\u003c\/button\u003e \u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket Characteristics\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eOperating Temperature: -40ºC to +85ºC\u003c\/li\u003e\n\u003cli\u003eStorage Temperature: -40ºC to +85ºC\u003c\/li\u003e\n\u003cli\u003eInstallation Temperature: 0ºC to +60ºC\u003c\/li\u003e\n\u003cli\u003eFlame Retardancy: UL Listed Type OFNP (ANSI\/NFPA 262) and FT6 (CSA C22.2 No. 232)\u003c\/li\u003e\n\u003cli\u003eCrush Resistance: 2,100 N\/cm\u003c\/li\u003e\n\u003cli\u003eImpact Resistance: 1,000 impacts\u003c\/li\u003e\n\u003cli\u003eFlex Resistance: 2,000 cycles\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"OCC","offers":[{"title":"2 Strand","offer_id":30010554843181,"sku":"BX002KSLX9YP","price":0.0,"currency_code":"USD","in_stock":true},{"title":"4 Strand","offer_id":31461205311549,"sku":"BX004KSLX9YP","price":0.0,"currency_code":"USD","in_stock":true},{"title":"6 Strand","offer_id":31461211013181,"sku":"BX006KSLX9YP","price":1.7,"currency_code":"USD","in_stock":true},{"title":"8 Strand","offer_id":31461211144253,"sku":"BX008KSLX9YP","price":0.0,"currency_code":"USD","in_stock":true},{"title":"12 Strand","offer_id":31461212520509,"sku":"BX012KSLX9YP","price":0.0,"currency_code":"USD","in_stock":true},{"title":"18 Strand","offer_id":31461213241405,"sku":"BX018KSLX9YP","price":0.0,"currency_code":"USD","in_stock":true},{"title":"24 Strand","offer_id":31461215174717,"sku":"BX024KSLX9YP","price":0.0,"currency_code":"USD","in_stock":true},{"title":"36 Strand","offer_id":31461216321597,"sku":"BX036KSLX9YP","price":0.0,"currency_code":"USD","in_stock":true},{"title":"48 Strand","offer_id":31461217566781,"sku":"BX048KSLX9YP","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0252\/1897\/3741\/products\/Breakout-SM.png?v=1567190842"},{"product_id":"breakout-fiber-optic-cable-multimode-62-5125-om1-indooroutdoor-riser","title":"Breakout Riser Multimode OM1 Fiber Optic Cable, Indoor\/Outdoor","description":"\u003cp\u003e\u003cimg style=\"background-color: #fff; border-radius: 10px; padding: 5px;\" height=\"65px\" width=\"115px\" alt=\"Made in USA\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0252\/1897\/3741\/files\/Made_In_USA.png?2208\"\u003e \u003cimg style=\"background-color: #fff; border-radius: 10px; padding: 5px;\" height=\"65px\" width=\"75px\" alt=\"UL Listed\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0252\/1897\/3741\/files\/UL_LISTED_LOGO_US.png?2209\"\u003e \u003cimg style=\"background-color: #fff; border-radius: 10px; padding: 5px;\" height=\"75px\" width=\"55px\" alt=\"RoHS Compliant\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0252\/1897\/3741\/files\/Bullets-_RoHS.jpg?2209\"\u003e \u003cmeta charset=\"utf-8\"\u003e\u003c\/p\u003e\n\u003ch5\u003e(We do not offer credits or returns for this item.)\u003c\/h5\u003e\n\u003cp\u003e\u003cstrong\u003eThis fiber cable is priced per foot and may include a minimum order length.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIf you would like to inquire about our custom fiber cable options such as terminated ends, pulleyes, and custom cut lengths, please call or email us.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003ci\u003ePlease call for shipping quote\u003c\/i\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch4\u003eDescription\u003c\/h4\u003e\n\u003ch2\u003eBreakout Fiber Optic Cable, Multimode, 62.5\/125 OM1, Indoor\/Outdoor, Riser\u003c\/h2\u003e\n\u003cp\u003e\u003cmeta charset=\"utf-8\"\u003e\u003cspan\u003eThe Breakout Riser OFNR MultiMode 62.5\/125 OM1 Fiber Cable is perfect for demanding installations needing robust fiber optic design for maximum protection. It's the easiest to install for direct termination of connectors to sub-units and direct runs to panels\/equipment. With direct termination, it adds strain relief for better connector retention during adjustments. UL Listed per NEC sections 770.179(b) for vertical runs in building riser shafts.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eCleaning your fiber connector end faces and components regularly is crucial for avoiding a total network failure. Ensure your optical fiber system is working properly and prevent major network issues with \u003ca alt=\"Fiber Cleaning Kits\" href=\"https:\/\/www.primuscable.com\/collections\/fiber-cleaning-kit\" target=\"_blank\"\u003e\u003cstrong\u003e fiber cleaning kits,\u003c\/strong\u003e\u003c\/a\u003e \u003ca alt=\"Fiber Cleaning Pens\" href=\"https:\/\/www.primuscable.com\/collections\/fiber-cleaning-pens\" target=\"_blank\"\u003e\u003cstrong\u003e pens,\u003c\/strong\u003e\u003c\/a\u003e\u003ca alt=\"Fiber Cleaning Fluids\" href=\"https:\/\/www.primuscable.com\/collections\/fiber-cleaning-fluids\" target=\"_blank\"\u003e\u003cstrong\u003e fluids,\u003c\/strong\u003e\u003c\/a\u003e and \u003ca alt=\"Fiber Cleaning Wipes\" href=\"https:\/\/www.primuscable.com\/collections\/fiber-cleaning-wipes\" target=\"_blank\"\u003e\u003cstrong\u003ewipes.\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003ch4\u003eFeatures\u003c\/h4\u003e\n\u003ch3\u003e\u003cspan style=\"text-decoration: underline;\"\u003eFeatures\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eHigh performance components and construction\u003c\/li\u003e\n\u003cli\u003eUL Listed in accordance with NEC sections 770.179(b) for use in vertical runs in building riser shafts or from floor to floor\u003c\/li\u003e\n\u003cli\u003eMost rugged and easy to install cable design for enterprise cabling applications\u003c\/li\u003e\n\u003cli\u003eCore-Locked™ outer jacket design for installation survivability, long-term, trouble free service\u003c\/li\u003e\n\u003cli\u003eIdeal for use in long, vertical installations\u003c\/li\u003e\n\u003cli\u003e2.5mm subcables can be direct-terminated with standard connectors (2.0mm and 2.9mm subcables also available)\u003c\/li\u003e\n\u003cli\u003eSubcabled fiber is environmentally and mechanically protected\u003c\/li\u003e\n\u003cli\u003eIdeal for use in point-to-point runs in adverse environments\u003c\/li\u003e\n\u003cli\u003eDirect termination to subcable provides additional strain relief for better connector retention during moves, adds, and changes\u003c\/li\u003e\n\u003cli\u003eDesign is ideal for direct pulling with mesh grips\u003c\/li\u003e\n\u003cli\u003eCable materials are indoor\/outdoor - UV, water and fungus resistant\u003c\/li\u003e\n\u003cli\u003eWide operating temperature range of -40ºC to +85ºC\u003c\/li\u003e\n\u003cli\u003eHigh performance \u003cmeta charset=\"utf-8\"\u003e \u003cspan\u003e900 um\u003c\/span\u003e tight buffered coating on each optical fiber for environmental and mechanical protection\u003c\/li\u003e\n\u003cli\u003eInterlocking armor can be applied to cables as an alternative to conduit installation\u003c\/li\u003e\n\u003cli\u003e2 to 72 fibers\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eIdeal for installations requiring an extremely rugged and reliable cable design where maximum mechanical and environmental protection are necessary\u003c\/li\u003e\n\u003cli\u003eEasiest cable to install where direct termination of connectors to sub-units and direct run to panels and equipment is desired\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eCost Savings\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eDirect termination to subcable may eliminate the need for patch panels and patch cords and reduces connector loss\u003c\/li\u003e\n\u003cli\u003e\n\u003cmeta charset=\"utf-8\"\u003e \u003cspan\u003e900 um\u003c\/span\u003e buffer eliminates the need for costly and time-consuming installation of fanout kits or pigtail splices because connectors terminate directly to the fiber\u003c\/li\u003e\n\u003cli\u003eHigh crush resistance may eliminate the need for innerduct\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eStandards List\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eUL 1651\u003c\/li\u003e\n\u003cli\u003eUL 1666\u003c\/li\u003e\n\u003cli\u003eGR-409-CORE\u003c\/li\u003e\n\u003cli\u003eICEA-S-104-696\u003c\/li\u003e\n\u003cli\u003eICEA-S-83-596\u003c\/li\u003e\n\u003cli\u003eTIA-568\u003c\/li\u003e\n\u003cli\u003eTIA-598\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eSpecifications\u003c\/h4\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0079\/8874\/0186\/files\/OCC_Breakout_OFNP_Specs.pdf?3934\" target=\"_blank\"\u003e \u003cbutton class=\"download-btn\"\u003eSpec Sheet\u003c\/button\u003e \u003c\/a\u003e \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0079\/8874\/0186\/files\/OCC-Ultra-Fox-perf_chart-1.pdf?1946\" target=\"_blank\"\u003e \u003cbutton class=\"download-btn\"\u003eFiber Performance Chart\u003c\/button\u003e \u003c\/a\u003e \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0079\/8874\/0186\/files\/OCC-Mil-Tac_Installation-General_Guidelines_Rev_B-1.pdf?3926\" target=\"_blank\"\u003e \u003cbutton class=\"download-btn\"\u003eGeneral Guidelines\u003c\/button\u003e \u003c\/a\u003e \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0079\/8874\/0186\/files\/OCC-Mil-Tac_Fiber_Optic_Field_Testing_Guidelines_Rev_A-1.pdf?3926\" target=\"_blank\"\u003e \u003cbutton class=\"download-btn\"\u003eTesting Guidelines\u003c\/button\u003e \u003c\/a\u003e \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0079\/8874\/0186\/files\/OCC-Mil-Tac_Storage_Handling_Rev_B-1.pdf?3926\" target=\"_blank\"\u003e \u003cbutton class=\"download-btn\"\u003eStorage Handling\u003c\/button\u003e \u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket Characteristics\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eOperating Temperature: -50ºC to +75ºC\u003c\/li\u003e\n\u003cli\u003eStorage Temperature: -55ºC to +85ºC\u003c\/li\u003e\n\u003cli\u003eInstallation Temperature: -30ºC to +60ºC\u003c\/li\u003e\n\u003cli\u003eFlame Retardancy: \u0026gt;UL Listed Type OFNR (UL 1666) and FT4 (CSA C22.2 No. 232)\u003c\/li\u003e\n\u003cli\u003eCrush Resistance: 2,200 N\/cm\u003c\/li\u003e\n\u003cli\u003eImpact Resistance: 1,500 impacts\u003c\/li\u003e\n\u003cli\u003eFlex Resistance: 2,000 cycles\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"OCC","offers":[{"title":"2 Strand","offer_id":30010554810413,"sku":"BX002DWLS9KR","price":0.0,"currency_code":"USD","in_stock":true},{"title":"4 Strand","offer_id":31460737548349,"sku":"BX004DWLS9KR","price":1.06,"currency_code":"USD","in_stock":true},{"title":"6 Strand","offer_id":31460738662461,"sku":"BX006DWLS9KR","price":0.0,"currency_code":"USD","in_stock":true},{"title":"8 Strand","offer_id":31460739579965,"sku":"BX008DWLS9KR","price":0.0,"currency_code":"USD","in_stock":true},{"title":"12 Strand","offer_id":31460740104253,"sku":"BX012DWLS9KR","price":0.0,"currency_code":"USD","in_stock":true},{"title":"18 Strand","offer_id":31460743413821,"sku":"BX018DWLS9KR","price":0.0,"currency_code":"USD","in_stock":true},{"title":"24 Strand","offer_id":31460744200253,"sku":"BX024DWLS9KR","price":0.0,"currency_code":"USD","in_stock":true},{"title":"36 Strand","offer_id":31460744298557,"sku":"BX036DWLS9KR","price":0.0,"currency_code":"USD","in_stock":true},{"title":"48 Strand","offer_id":31460744757309,"sku":"BX048DWLS9KR","price":0.0,"currency_code":"USD","in_stock":true},{"title":"60 Strand","offer_id":31460754882621,"sku":"BX060DWLS9KR","price":0.0,"currency_code":"USD","in_stock":true},{"title":"72 Strand","offer_id":31460753801277,"sku":"BX072DWLS9KR","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0252\/1897\/3741\/products\/Breakout-IO.png?v=1567190842"},{"product_id":"breakout-fiber-optic-cable-single-mode-9125-indooroutdoor-riser","title":"Indoor\/Outdoor Breakout Riser Single Mode Fiber Optic Cable","description":"\u003cp\u003e\u003cimg style=\"background-color: #fff; border-radius: 10px; padding: 5px;\" height=\"65px\" width=\"115px\" alt=\"Made in USA\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0252\/1897\/3741\/files\/Made_In_USA.png?2208\"\u003e \u003cimg style=\"background-color: #fff; border-radius: 10px; padding: 5px;\" height=\"65px\" width=\"75px\" alt=\"UL Listed\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0252\/1897\/3741\/files\/UL_LISTED_LOGO_US.png?2209\"\u003e \u003cimg style=\"background-color: #fff; border-radius: 10px; padding: 5px;\" height=\"75px\" width=\"55px\" alt=\"RoHS Compliant\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0252\/1897\/3741\/files\/Bullets-_RoHS.jpg?2209\"\u003e \u003cmeta charset=\"utf-8\"\u003e\u003c\/p\u003e\n\u003ch5\u003e(We do not offer credits or returns for this item.)\u003c\/h5\u003e\n\u003cp\u003e\u003cstrong\u003eThis fiber cable is priced per foot and may include a minimum order length.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIf you would like to inquire about our custom fiber cable options such as terminated ends, pulleyes, and custom cut lengths, please call or email us.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003ci\u003ePlease call for shipping quote\u003c\/i\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch4\u003eDescription\u003c\/h4\u003e\n\u003ch2\u003eBreakout Fiber Optic Cable, Single Mode, 9\/125, Indoor\/Outdoor, Riser\u003c\/h2\u003e\n\u003cp\u003e\u003cmeta charset=\"utf-8\"\u003e\u003cspan\u003eIdeal for rugged installations, this Breakout Riser OFNR Single Mode 9\/125 OS2 Fiber Cable ensures maximum mechanical and environmental protection. It simplifies connector termination directly to sub-units and panels, offering added strain relief for improved connector retention. Utilizing high-performance components, these cables are UL Listed for vertical runs in building riser shafts according to NEC sections 770.179(b).\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eCleaning your fiber connector end faces and components regularly is crucial for avoiding a total network failure. Ensure your optical fiber system is working properly and prevent major network issues with \u003ca alt=\"Fiber Cleaning Kits\" href=\"https:\/\/www.primuscable.com\/collections\/fiber-cleaning-kit\" target=\"_blank\"\u003e\u003cstrong\u003e fiber cleaning kits,\u003c\/strong\u003e\u003c\/a\u003e \u003ca alt=\"Fiber Cleaning Pens\" href=\"https:\/\/www.primuscable.com\/collections\/fiber-cleaning-pens\" target=\"_blank\"\u003e\u003cstrong\u003e pens,\u003c\/strong\u003e\u003c\/a\u003e\u003ca alt=\"Fiber Cleaning Fluids\" href=\"https:\/\/www.primuscable.com\/collections\/fiber-cleaning-fluids\" target=\"_blank\"\u003e\u003cstrong\u003e fluids,\u003c\/strong\u003e\u003c\/a\u003e and \u003ca alt=\"Fiber Cleaning Wipes\" href=\"https:\/\/www.primuscable.com\/collections\/fiber-cleaning-wipes\" target=\"_blank\"\u003e\u003cstrong\u003ewipes.\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003ch4\u003eFeatures\u003c\/h4\u003e\n\u003ch3\u003e\u003cspan style=\"text-decoration: underline;\"\u003eFeatures\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eHigh performance components and construction\u003c\/li\u003e\n\u003cli\u003eUL Listed in accordance with NEC sections 770.179(b) for use in vertical runs in building riser shafts or from floor to floor\u003c\/li\u003e\n\u003cli\u003eMost rugged and easy to install cable design for enterprise cabling applications\u003c\/li\u003e\n\u003cli\u003eCore-Locked outer jacket design for installation survivability, long-term, trouble free service\u003c\/li\u003e\n\u003cli\u003eIdeal for use in long, vertical installations\u003c\/li\u003e\n\u003cli\u003e2.5mm sub-cables can be direct-terminated with standard connectors (2.0mm and 2.9mm sub-cables also available)\u003c\/li\u003e\n\u003cli\u003eSubcabled fiber is environmentally and mechanically protected\u003c\/li\u003e\n\u003cli\u003eIdeal for use in point-to-point runs in adverse environments\u003c\/li\u003e\n\u003cli\u003eDirect termination to sub-cable provides additional strain relief for better connector retention during moves, adds, and changes\u003c\/li\u003e\n\u003cli\u003eDesign is ideal for direct pulling with mesh grips\u003c\/li\u003e\n\u003cli\u003eCable materials are indoor\/outdoor - UV, water and fungus resistant\u003c\/li\u003e\n\u003cli\u003eWide operating temperature range of -40\u003cmeta charset=\"utf-8\"\u003e \u003cspan\u003eº\u003c\/span\u003eC to +85\u003cmeta charset=\"utf-8\"\u003e \u003cspan\u003eº\u003c\/span\u003eC\u003c\/li\u003e\n\u003cli\u003eHigh performance 900 _m tight buffered coating on each optical fiber for environmental and mechanical protection\u003c\/li\u003e\n\u003cli\u003eInterlocking armor can be applied to cables as an alternative to conduit installation\u003c\/li\u003e\n\u003cli\u003e2 to 72 fibers\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eIdeal for installations requiring an extremely rugged and reliable cable design where maximum mechanical and environmental protection are necessary\u003c\/li\u003e\n\u003cli\u003eEasiest cable to install where direct termination of connectors to sub-units and direct run to panels and equipment is desired\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eCost Savings\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eDirect termination to sub-cable may eliminate the need for patch panels and patch cords and reduces connector loss\u003c\/li\u003e\n\u003cli\u003e900 _m buffer eliminates the need for costly and time-consuming installation of fanout kits or pigtail splices because connectors terminate directly to the fiber\u003c\/li\u003e\n\u003cli\u003eHigh crush resistance may eliminate the need for innerduct\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eStandards List\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eUL 1651\u003c\/li\u003e\n\u003cli\u003eUL 1666\u003c\/li\u003e\n\u003cli\u003eGR-409-CORE\u003c\/li\u003e\n\u003cli\u003eICEA-S-104-696\u003c\/li\u003e\n\u003cli\u003eICEA-S-83-596\u003c\/li\u003e\n\u003cli\u003eTIA-568\u003c\/li\u003e\n\u003cli\u003eTIA-598\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eSpecifications\u003c\/h4\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0079\/8874\/0186\/files\/OCC_Breakout_OFNP_Specs.pdf?3934\" target=\"_blank\"\u003e \u003cbutton class=\"download-btn\"\u003eSpec Sheet\u003c\/button\u003e \u003c\/a\u003e \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0079\/8874\/0186\/files\/OCC-Ultra-Fox-perf_chart-1.pdf?1946\" target=\"_blank\"\u003e \u003cbutton class=\"download-btn\"\u003eFiber Performance Chart\u003c\/button\u003e \u003c\/a\u003e \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0079\/8874\/0186\/files\/OCC-Mil-Tac_Installation-General_Guidelines_Rev_B-1.pdf?3926\" target=\"_blank\"\u003e \u003cbutton class=\"download-btn\"\u003eGeneral Guidelines\u003c\/button\u003e \u003c\/a\u003e \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0079\/8874\/0186\/files\/OCC-Mil-Tac_Fiber_Optic_Field_Testing_Guidelines_Rev_A-1.pdf?3926\" target=\"_blank\"\u003e \u003cbutton class=\"download-btn\"\u003eTesting Guidelines\u003c\/button\u003e \u003c\/a\u003e \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0079\/8874\/0186\/files\/OCC-Mil-Tac_Storage_Handling_Rev_B-1.pdf?3926\" target=\"_blank\"\u003e \u003cbutton class=\"download-btn\"\u003eStorage Handling\u003c\/button\u003e \u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket Characteristics\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eOperating Temperature: -50ºC to +75ºC\u003c\/li\u003e\n\u003cli\u003eStorage Temperature: -55ºC to +85ºC\u003c\/li\u003e\n\u003cli\u003eInstallation Temperature: -30ºC to +60ºC\u003c\/li\u003e\n\u003cli\u003eFlame Retardancy: \u0026gt;UL Listed Type OFNR (UL 1666) and FT4 (CSA C22.2 No. 232)\u003c\/li\u003e\n\u003cli\u003eCrush Resistance: 2,200 N\/cm\u003c\/li\u003e\n\u003cli\u003eImpact Resistance: 1,500 impacts\u003c\/li\u003e\n\u003cli\u003eFlex Resistance: 2,000 cycles\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"OCC","offers":[{"title":"2 Strand","offer_id":30010554875949,"sku":"BX002DSLX9KR","price":0.0,"currency_code":"USD","in_stock":true},{"title":"4 Strand","offer_id":31460488708157,"sku":"BX004DSLX9KR","price":0.0,"currency_code":"USD","in_stock":true},{"title":"6 Strand","offer_id":31460488839229,"sku":"BX006DSLX9KR","price":0.0,"currency_code":"USD","in_stock":true},{"title":"8 Strand","offer_id":31460593238077,"sku":"BX008DSLX9KR","price":0.0,"currency_code":"USD","in_stock":true},{"title":"12 Strand","offer_id":31460593729597,"sku":"BX012DSLA9KR","price":0.0,"currency_code":"USD","in_stock":true},{"title":"18 Strand","offer_id":31460594679869,"sku":"BX018DSLX9KR","price":0.0,"currency_code":"USD","in_stock":true},{"title":"24 Strand","offer_id":31460597137469,"sku":"BX024DSLX9KR","price":0.0,"currency_code":"USD","in_stock":true},{"title":"36 Strand","offer_id":31460597694525,"sku":"BX036DSLX9KR","price":0.0,"currency_code":"USD","in_stock":true},{"title":"48 Strand","offer_id":31460598874173,"sku":"BX048DSLX9KR","price":0.0,"currency_code":"USD","in_stock":true},{"title":"60 Strand","offer_id":31460603297853,"sku":"BX060DSLX9KR","price":0.0,"currency_code":"USD","in_stock":true},{"title":"72 Strand","offer_id":31460603920445,"sku":"BX072DSLX9KR","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0252\/1897\/3741\/products\/Breakout-IO_584a619c-7d0f-4d4d-b92f-b84145b8c3c6.png?v=1567190842"},{"product_id":"breakout-fiber-optic-cable-multimode-50125-10-gig-om3-indooroutdoor-plenum","title":"Indoor\/Outdoor Breakout Plenum Multimode 10 Gig OM3 Fiber Optic Cable","description":"\u003cp\u003e\u003cimg style=\"background-color: #fff; border-radius: 10px; padding: 5px;\" height=\"65px\" width=\"115px\" alt=\"Made in USA\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0252\/1897\/3741\/files\/Made_In_USA.png?2208\"\u003e \u003cimg style=\"background-color: #fff; border-radius: 10px; padding: 5px;\" height=\"65px\" width=\"75px\" alt=\"UL Listed\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0252\/1897\/3741\/files\/UL_LISTED_LOGO_US.png?2209\"\u003e \u003cimg style=\"background-color: #fff; border-radius: 10px; padding: 5px;\" height=\"75px\" width=\"55px\" alt=\"RoHS Compliant\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0252\/1897\/3741\/files\/Bullets-_RoHS.jpg?2209\"\u003e \u003cmeta charset=\"utf-8\"\u003e\u003c\/p\u003e\n\u003ch5\u003e(We do not offer credits or returns for this item.)\u003c\/h5\u003e\n\u003cp\u003e\u003cstrong\u003eThis fiber cable is priced per foot and may include a minimum order length.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIf you would like to inquire about our custom fiber cable options such as terminated ends, pulleyes, and custom cut lengths, please call or email us.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003ci\u003ePlease call for shipping quote\u003c\/i\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch4\u003eDescription\u003c\/h4\u003e\n\u003ch2\u003eBreakout OFNP Multimode OM3 Cable\u003c\/h2\u003e\n\u003cp\u003e\u003cmeta charset=\"utf-8\"\u003e\u003cspan\u003eThe Breakout Plenum OFNP MultiMode 50\/125 OM3 Fiber Cable is perfect for robust installations needing maximum protection. It's effortless to install with direct termination to sub-units and panels\/equipment, providing additional strain relief for improved connector retention. UL Listed per NEC sections 770.179(b) for ducts, plenums, and air-handling spaces.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eCleaning your fiber connector end faces and components regularly is crucial for avoiding a total network failure. Ensure your optical fiber system is working properly and prevent major network issues with \u003ca alt=\"Fiber Cleaning Kits\" href=\"https:\/\/www.primuscable.com\/collections\/fiber-cleaning-kit\" target=\"_blank\"\u003e\u003cstrong\u003e fiber cleaning kits,\u003c\/strong\u003e\u003c\/a\u003e \u003ca alt=\"Fiber Cleaning Pens\" href=\"https:\/\/www.primuscable.com\/collections\/fiber-cleaning-pens\" target=\"_blank\"\u003e\u003cstrong\u003e pens,\u003c\/strong\u003e\u003c\/a\u003e\u003ca alt=\"Fiber Cleaning Fluids\" href=\"https:\/\/www.primuscable.com\/collections\/fiber-cleaning-fluids\" target=\"_blank\"\u003e\u003cstrong\u003e fluids,\u003c\/strong\u003e\u003c\/a\u003e and \u003ca alt=\"Fiber Cleaning Wipes\" href=\"https:\/\/www.primuscable.com\/collections\/fiber-cleaning-wipes\" target=\"_blank\"\u003e\u003cstrong\u003ewipes.\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003ch4\u003eFeatures\u003c\/h4\u003e\n\u003ch3\u003e\u003cspan style=\"text-decoration: underline;\"\u003eFeatures\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eHigh performance components and construction\u003c\/li\u003e\n\u003cli\u003eUL Listed in accordance with NEC sections 770.179(b) for use in ducts, plenums and air-handling spaces\u003c\/li\u003e\n\u003cli\u003eMost rugged and easy to install cable design for enterprise cabling applications\u003c\/li\u003e\n\u003cli\u003eCore-Locked™ outer jacket design for installation survivability, long-term, trouble free service\u003c\/li\u003e\n\u003cli\u003eIdeal for use in long, vertical installations\u003c\/li\u003e\n\u003cli\u003e2.0mm subcables can be direct-terminated with standard connectors (2.5mm and 2.9mm subcables also available)\u003c\/li\u003e\n\u003cli\u003eSubcabled fiber is environmentally and mechanically protected\u003c\/li\u003e\n\u003cli\u003eIdeal for use in point-to-point runs in adverse environments\u003c\/li\u003e\n\u003cli\u003eDirect termination to subcable provides additional strain relief for better connector retention during moves, adds, and changes\u003c\/li\u003e\n\u003cli\u003eDesign is ideal for direct pulling with mesh grips\u003c\/li\u003e\n\u003cli\u003eCable materials are indoor\/outdoor - UV, water and fungus resistant\u003c\/li\u003e\n\u003cli\u003eWide operating temperature range of -40ºC to +85ºC\u003c\/li\u003e\n\u003cli\u003eHigh performance 900 um tight buffered coating on each optical fiber for environmental and mechanical protection\u003c\/li\u003e\n\u003cli\u003eInterlocking armor can be applied to cables as an alternative to conduit installation\u003c\/li\u003e\n\u003cli\u003e2 to 48 fibers\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eIdeal for installations requiring an extremely rugged and reliable cable design where maximum mechanical and environmental protection are necessary\u003c\/li\u003e\n\u003cli\u003eEasiest cable to install where direct termination of connectors to sub-units and direct run to panels and equipment is desired\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eCost Savings\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eDirect termination to subcable may eliminate the need for patch panels and patch cords and reduces connector loss\u003c\/li\u003e\n\u003cli\u003e900 um buffer eliminates the need for costly and time-consuming installation of fanout kits or pigtail splices because connectors terminate directly to the fiber\u003c\/li\u003e\n\u003cli\u003eHigh crush resistance may eliminate the need for innerduct\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eStandards List\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eUL 1651\u003c\/li\u003e\n\u003cli\u003eANSI\/NFPA 262\u003c\/li\u003e\n\u003cli\u003eGR-409-CORE\u003c\/li\u003e\n\u003cli\u003eICEA-S-104-696\u003c\/li\u003e\n\u003cli\u003eICEA-S-83-596\u003c\/li\u003e\n\u003cli\u003eTIA-568\u003c\/li\u003e\n\u003cli\u003eTIA-598\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eSpecifications\u003c\/h4\u003e\n\u003ch3\u003e\u003cbr\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0079\/8874\/0186\/files\/OCC_Breakout_OFNP_Specs.pdf?3934\" target=\"_blank\"\u003e \u003cbutton class=\"download-btn\"\u003eSpec Sheet\u003c\/button\u003e \u003c\/a\u003e \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0079\/8874\/0186\/files\/OCC-Ultra-Fox-perf_chart-1.pdf?1946\" target=\"_blank\"\u003e \u003cbutton class=\"download-btn\"\u003eFiber Performance Chart\u003c\/button\u003e \u003c\/a\u003e \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0079\/8874\/0186\/files\/OCC-Mil-Tac_Installation-General_Guidelines_Rev_B-1.pdf?3926\" target=\"_blank\"\u003e \u003cbutton class=\"download-btn\"\u003eGeneral Guidelines\u003c\/button\u003e \u003c\/a\u003e \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0079\/8874\/0186\/files\/OCC-Mil-Tac_Fiber_Optic_Field_Testing_Guidelines_Rev_A-1.pdf?3926\" target=\"_blank\"\u003e \u003cbutton class=\"download-btn\"\u003eTesting Guidelines\u003c\/button\u003e \u003c\/a\u003e \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0079\/8874\/0186\/files\/OCC-Mil-Tac_Storage_Handling_Rev_B-1.pdf?3926\" target=\"_blank\"\u003e \u003cbutton class=\"download-btn\"\u003eStorage Handling\u003c\/button\u003e \u003c\/a\u003e \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0079\/8874\/0186\/files\/OCC_Recommended_Duct_Installation_Guideline_Rev_2-1.pdf?3933\" target=\"_blank\"\u003e \u003cbutton class=\"download-btn\"\u003eDuct Install Guidelines\u003c\/button\u003e \u003c\/a\u003e \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0079\/8874\/0186\/files\/OCC_Installation-Cable_Tray_Vertical_Rise_Guidelines_Rev_A-1.pdf?3933\" target=\"_blank\"\u003e \u003cbutton class=\"download-btn\"\u003eCable Tray Guidelines\u003c\/button\u003e \u003c\/a\u003e \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0079\/8874\/0186\/files\/OCC_Breakout_and_Subgrouping_Cable_Pulling_Grip_Installation_Procedure_Rev._1-1.pdf?3933\" target=\"_blank\"\u003e \u003cbutton class=\"download-btn\"\u003eCable Pulling Installation\u003c\/button\u003e \u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket Characteristics\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eOperating Temperature: -40ºC to +85ºC\u003c\/li\u003e\n\u003cli\u003eStorage Temperature: -40ºC to +85ºC\u003c\/li\u003e\n\u003cli\u003eInstallation Temperature: 0ºC to +60ºC\u003c\/li\u003e\n\u003cli\u003eFlame Retardancy: UL Listed Type OFNP (ANSI\/NFPA 262) and FT6 (CSA C22.2 No. 232)\u003c\/li\u003e\n\u003cli\u003eCrush Resistance: 2,100 N\/cm\u003c\/li\u003e\n\u003cli\u003eImpact Resistance: 1,000 impacts\u003c\/li\u003e\n\u003cli\u003eFlex Resistance: 2,000 cycles\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"OCC","offers":[{"title":"2 Strand","offer_id":30010553597997,"sku":"BX002KALT9QP","price":0.0,"currency_code":"USD","in_stock":true},{"title":"4 Strand","offer_id":31461357158461,"sku":"BX004KALT9QP","price":0.0,"currency_code":"USD","in_stock":true},{"title":"6 Strand","offer_id":31461358764093,"sku":"BX006KALT9QP","price":0.0,"currency_code":"USD","in_stock":true},{"title":"8 Strand","offer_id":31461358829629,"sku":"BX008KALT9QP","price":0.0,"currency_code":"USD","in_stock":true},{"title":"12 Strand","offer_id":31461361221693,"sku":"BX012KALT9QP","price":0.0,"currency_code":"USD","in_stock":true},{"title":"18 Strand","offer_id":31461369970749,"sku":"BX018KALT9QP","price":0.0,"currency_code":"USD","in_stock":true},{"title":"24 Strand","offer_id":31461363613757,"sku":"BX024KALT9QP","price":0.0,"currency_code":"USD","in_stock":true},{"title":"36 Strand","offer_id":31461367971901,"sku":"BX036KALT9QP","price":0.0,"currency_code":"USD","in_stock":true},{"title":"48 Strand","offer_id":31461368660029,"sku":"BX048KALT9QP","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0252\/1897\/3741\/products\/Breakout-10G.png?v=1567190842"},{"product_id":"breakout-fiber-optic-cable-multimode-62-5125-om1-indooroutdoor-plenum","title":"Breakout Plenum Fiber Optic Cable, Multimode OM1, Indoor\/Outdoor","description":"\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0252\/1897\/3741\/files\/Made_In_USA.png?2208\" alt=\"Made in USA\" width=\"115px\" height=\"65px\" style=\"background-color: #fff; border-radius: 10px; padding: 5px;\"\u003e \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0252\/1897\/3741\/files\/UL_LISTED_LOGO_US.png?2209\" alt=\"UL Listed\" width=\"75px\" height=\"65px\" style=\"background-color: #fff; border-radius: 10px; padding: 5px;\"\u003e \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0252\/1897\/3741\/files\/Bullets-_RoHS.jpg?2209\" alt=\"RoHS Compliant\" width=\"55px\" height=\"75px\" style=\"background-color: #fff; border-radius: 10px; padding: 5px;\"\u003e \u003cmeta charset=\"utf-8\"\u003e\u003c\/p\u003e\n\u003ch5\u003e(We do not offer credits or returns for this item.)\u003c\/h5\u003e\n\u003cp\u003e\u003cstrong\u003eThis fiber cable is priced per foot and may include a minimum order length.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIf you would like to inquire about our custom fiber cable options such as terminated ends, pulleyes, and custom cut lengths, please call or email us.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003ci\u003ePlease call for shipping quote\u003c\/i\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch4\u003eDescription\u003c\/h4\u003e\n\u003ch2\u003eBreakout Fiber Optic Cable, Multimode, 62.5\/125 OM1, Indoor\/Outdoor, Plenum\u003c\/h2\u003e\n\u003cp\u003eThis Breakout Plenum OFNP MultiMode 62.5\/125 OM1 Fiber Cable is ideal for installations requiring an extremely rugged and reliable fiber optic cable design where maximum mechanical and environmental protection are necessary. It's the easiest fiber cable to install where direct termination of connectors to sub-units and direct run to panels and equipment is desired. Direct termination of the plenum breakout fiber cable to each subcable provides additional strain relief for better connector retention during moves, adds, and changes. Breakout plenum fiber cables utilize high performance components and construction and are UL Listed in accordance with NEC sections 770.179(b) for use in ducts, plenums and air-handling spaces.\u003c\/p\u003e\n\u003cp\u003eCleaning your fiber connector end faces and components regularly is crucial for avoiding a total network failure. Ensure your optical fiber system is working properly and prevent major network issues with \u003ca href=\"https:\/\/www.primuscable.com\/collections\/fiber-cleaning-kit\" alt=\"Fiber Cleaning Kits\" target=\"_blank\"\u003e\u003cstrong\u003e fiber cleaning kits,\u003c\/strong\u003e\u003c\/a\u003e \u003ca href=\"https:\/\/www.primuscable.com\/collections\/fiber-cleaning-pens\" alt=\"Fiber Cleaning Pens\" target=\"_blank\"\u003e\u003cstrong\u003e pens,\u003c\/strong\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/www.primuscable.com\/collections\/fiber-cleaning-fluids\" alt=\"Fiber Cleaning Fluids\" target=\"_blank\"\u003e\u003cstrong\u003e fluids,\u003c\/strong\u003e\u003c\/a\u003e and \u003ca href=\"https:\/\/www.primuscable.com\/collections\/fiber-cleaning-wipes\" alt=\"Fiber Cleaning Wipes\" target=\"_blank\"\u003e\u003cstrong\u003ewipes.\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003ch4\u003eFeatures\u003c\/h4\u003e\n\u003ch3\u003e\u003cspan style=\"text-decoration: underline;\"\u003eFeatures\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eHigh performance components and construction\u003c\/li\u003e\n\u003cli\u003eUL Listed in accordance with NEC sections 770.179(b) for use in ducts, plenums and air-handling spaces\u003c\/li\u003e\n\u003cli\u003eMost rugged and easy to install cable design for enterprise cabling applications\u003c\/li\u003e\n\u003cli\u003eCore-Locked™ outer jacket design for installation survivability, long-term, trouble free service\u003c\/li\u003e\n\u003cli\u003eIdeal for use in long, vertical installations\u003c\/li\u003e\n\u003cli\u003e2.0mm subcables can be direct-terminated with standard connectors (2.5mm and 2.9mm subcables also available)\u003c\/li\u003e\n\u003cli\u003eSubcabled fiber is environmentally and mechanically protected\u003c\/li\u003e\n\u003cli\u003eIdeal for use in point-to-point runs in adverse environments\u003c\/li\u003e\n\u003cli\u003eDirect termination to subcable provides additional strain relief for better connector retention during moves, adds, and changes\u003c\/li\u003e\n\u003cli\u003eDesign is ideal for direct pulling with mesh grips\u003c\/li\u003e\n\u003cli\u003eCable materials are indoor\/outdoor - UV, water and fungus resistant\u003c\/li\u003e\n\u003cli\u003eWide operating temperature range of -40ºC to +85ºC\u003c\/li\u003e\n\u003cli\u003eHigh performance 900 um tight buffered coating on each optical fiber for environmental and mechanical protection\u003c\/li\u003e\n\u003cli\u003eInterlocking armor can be applied to cables as an alternative to conduit installation\u003c\/li\u003e\n\u003cli\u003e2 to 48 fibers\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eIdeal for installations requiring an extremely rugged and reliable cable design where maximum mechanical and environmental protection are necessary\u003c\/li\u003e\n\u003cli\u003eEasiest cable to install where direct termination of connectors to sub-units and direct run to panels and equipment is desired\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eCost Savings\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eDirect termination to subcable may eliminate the need for patch panels and patch cords and reduces connector loss\u003c\/li\u003e\n\u003cli\u003e900 um buffer eliminates the need for costly and time-consuming installation of fanout kits or pigtail splices because connectors terminate directly to the fiber\u003c\/li\u003e\n\u003cli\u003eHigh crush resistance may eliminate the need for innerduct\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eStandards List\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eUL 1651\u003c\/li\u003e\n\u003cli\u003eANSI\/NFPA 262\u003c\/li\u003e\n\u003cli\u003eGR-409-CORE\u003c\/li\u003e\n\u003cli\u003eICEA-S-104-696\u003c\/li\u003e\n\u003cli\u003eICEA-S-83-596\u003c\/li\u003e\n\u003cli\u003eTIA-568\u003c\/li\u003e\n\u003cli\u003eTIA-598\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eSpecifications\u003c\/h4\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0079\/8874\/0186\/files\/OCC_Breakout_OFNP_Specs.pdf?3934\" target=\"_blank\"\u003e \u003cbutton class=\"download-btn\"\u003eSpec Sheet\u003c\/button\u003e \u003c\/a\u003e \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0079\/8874\/0186\/files\/OCC-Ultra-Fox-perf_chart-1.pdf?1946\" target=\"_blank\"\u003e \u003cbutton class=\"download-btn\"\u003eFiber Performance Chart\u003c\/button\u003e \u003c\/a\u003e \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0079\/8874\/0186\/files\/OCC-Mil-Tac_Installation-General_Guidelines_Rev_B-1.pdf?3926\" target=\"_blank\"\u003e \u003cbutton class=\"download-btn\"\u003eGeneral Guidelines\u003c\/button\u003e \u003c\/a\u003e \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0079\/8874\/0186\/files\/OCC-Mil-Tac_Fiber_Optic_Field_Testing_Guidelines_Rev_A-1.pdf?3926\" target=\"_blank\"\u003e \u003cbutton class=\"download-btn\"\u003eTesting Guidelines\u003c\/button\u003e \u003c\/a\u003e \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0079\/8874\/0186\/files\/OCC-Mil-Tac_Storage_Handling_Rev_B-1.pdf?3926\" target=\"_blank\"\u003e \u003cbutton class=\"download-btn\"\u003eStorage Handling\u003c\/button\u003e \u003c\/a\u003e \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0079\/8874\/0186\/files\/OCC_Recommended_Duct_Installation_Guideline_Rev_2-1.pdf?3933\" target=\"_blank\"\u003e \u003cbutton class=\"download-btn\"\u003eDuct Install Guidelines\u003c\/button\u003e \u003c\/a\u003e \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0079\/8874\/0186\/files\/OCC_Installation-Cable_Tray_Vertical_Rise_Guidelines_Rev_A-1.pdf?3933\" target=\"_blank\"\u003e \u003cbutton class=\"download-btn\"\u003eCable Tray Guidelines\u003c\/button\u003e \u003c\/a\u003e \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0079\/8874\/0186\/files\/OCC_Breakout_and_Subgrouping_Cable_Pulling_Grip_Installation_Procedure_Rev._1-1.pdf?3933\" target=\"_blank\"\u003e \u003cbutton class=\"download-btn\"\u003eCable Pulling Installation\u003c\/button\u003e \u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket Characteristics\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eOperating Temperature: -40ºC to +85ºC\u003c\/li\u003e\n\u003cli\u003eStorage Temperature: -40ºC to +85ºC\u003c\/li\u003e\n\u003cli\u003eInstallation Temperature: 0ºC to +60ºC\u003c\/li\u003e\n\u003cli\u003eFlame Retardancy: UL Listed Type OFNP (ANSI\/NFPA 262) and FT6 (CSA C22.2 No. 232)\u003c\/li\u003e\n\u003cli\u003eCrush Resistance: 2,100 N\/cm\u003c\/li\u003e\n\u003cli\u003eImpact Resistance: 1,000 impacts\u003c\/li\u003e\n\u003cli\u003eFlex Resistance: 2,000 cycles\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"OCC","offers":[{"title":"2 Strand","offer_id":30010554744877,"sku":"BX002KWLS9OP","price":1.16,"currency_code":"USD","in_stock":true},{"title":"4 Strand","offer_id":31461298012221,"sku":"BX004KWLS9OP","price":1.34,"currency_code":"USD","in_stock":true},{"title":"6 Strand","offer_id":31461298667581,"sku":"BX006KWLS9OP","price":0.0,"currency_code":"USD","in_stock":true},{"title":"8 Strand","offer_id":31461302960189,"sku":"BX008KWLS9OP","price":0.0,"currency_code":"USD","in_stock":true},{"title":"12 Strand","offer_id":31461306368061,"sku":"BX012KWLS9OP","price":3.62,"currency_code":"USD","in_stock":true},{"title":"18 Strand","offer_id":31461306499133,"sku":"BX018KWLS9OP","price":0.0,"currency_code":"USD","in_stock":true},{"title":"24 Strand","offer_id":31461309710397,"sku":"BX024KWLS9OP","price":0.0,"currency_code":"USD","in_stock":true},{"title":"36 Strand","offer_id":31461310464061,"sku":"BX036KWLS9OP","price":0.0,"currency_code":"USD","in_stock":true},{"title":"48 Strand","offer_id":31461312790589,"sku":"BX048KWLS9OP","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0252\/1897\/3741\/products\/Breakout-MM.png?v=1567190843"},{"product_id":"breakout-fiber-optic-cable-multimode-50125-10-gig-om3-indooroutdoor-riser","title":"Breakout Riser Fiber Optic Cable, Multimode 10 Gig OM3, Indoor\/Outdoor","description":"\u003cp\u003e\u003cimg style=\"background-color: #fff; border-radius: 10px; padding: 5px;\" height=\"65px\" width=\"115px\" alt=\"Made in USA\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0252\/1897\/3741\/files\/Made_In_USA.png?2208\"\u003e \u003cimg style=\"background-color: #fff; border-radius: 10px; padding: 5px;\" height=\"65px\" width=\"75px\" alt=\"UL Listed\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0252\/1897\/3741\/files\/UL_LISTED_LOGO_US.png?2209\"\u003e \u003cimg style=\"background-color: #fff; border-radius: 10px; padding: 5px;\" height=\"75px\" width=\"55px\" alt=\"RoHS Compliant\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0252\/1897\/3741\/files\/Bullets-_RoHS.jpg?2209\"\u003e \u003cmeta charset=\"utf-8\"\u003e\u003c\/p\u003e\n\u003ch5\u003e(We do not offer credits or returns for this item.)\u003c\/h5\u003e\n\u003cp\u003e\u003cstrong\u003eThis fiber cable is priced per foot and may include a minimum order length.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIf you would like to inquire about our custom fiber cable options such as terminated ends, pulleyes, and custom cut lengths, please call or email us.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003ci\u003ePlease call for shipping quote\u003c\/i\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch4\u003eDescription\u003c\/h4\u003e\n\u003ch2\u003eBreakout Fiber Optic Cable, Multimode, 50\/125 10 Gig OM3, Indoor\/Outdoor, Riser\u003c\/h2\u003e\n\u003cp\u003eThis Breakout Riser OFNR MultiMode 50\/125 OM3 Fiber Cable is ideal for installations requiring an extremely rugged and reliable fiber optic cable design where maximum mechanical and environmental protection are necessary. It's the easiest cable to install where direct termination of connectors to sub-units and direct run to panels and equipment is desired. Direct termination of the riser breakout fiber cable to each subcable provides additional strain relief for better connector retention during moves, adds, and changes. Breakout riser fiber cables utilize high performance components and construction and are UL Listed in accordance with NEC sections 770.179(b) for use in vertical runs in building riser shafts from floor to floor.\u003c\/p\u003e\n\u003cp\u003eCleaning your fiber connector end faces and components regularly is crucial for avoiding a total network failure. Ensure your optical fiber system is working properly and prevent major network issues with \u003ca alt=\"Fiber Cleaning Kits\" href=\"https:\/\/www.primuscable.com\/collections\/fiber-cleaning-kit\" target=\"_blank\"\u003e\u003cstrong\u003e fiber cleaning kits,\u003c\/strong\u003e\u003c\/a\u003e \u003ca alt=\"Fiber Cleaning Pens\" href=\"https:\/\/www.primuscable.com\/collections\/fiber-cleaning-pens\" target=\"_blank\"\u003e\u003cstrong\u003e pens,\u003c\/strong\u003e\u003c\/a\u003e\u003ca alt=\"Fiber Cleaning Fluids\" href=\"https:\/\/www.primuscable.com\/collections\/fiber-cleaning-fluids\" target=\"_blank\"\u003e\u003cstrong\u003e fluids,\u003c\/strong\u003e\u003c\/a\u003e and \u003ca alt=\"Fiber Cleaning Wipes\" href=\"https:\/\/www.primuscable.com\/collections\/fiber-cleaning-wipes\" target=\"_blank\"\u003e\u003cstrong\u003ewipes.\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003ch4\u003eFeatures\u003c\/h4\u003e\n\u003ch3\u003e\u003cspan style=\"text-decoration: underline;\"\u003eFeatures\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eHigh performance components and construction\u003c\/li\u003e\n\u003cli\u003eUL Listed in accordance with NEC sections 770.179(b) for use in vertical runs in building riser shafts or from floor to floor\u003c\/li\u003e\n\u003cli\u003eMost rugged and easy to install cable design for enterprise cabling applications\u003c\/li\u003e\n\u003cli\u003eCore-Locked™ outer jacket design for installation survivability, long-term, trouble free service\u003c\/li\u003e\n\u003cli\u003eIdeal for use in long, vertical installations\u003c\/li\u003e\n\u003cli\u003e2.5mm subcables can be direct-terminated with standard connectors (2.0mm and 2.9mm subcables also available)\u003c\/li\u003e\n\u003cli\u003eSubcabled fiber is environmentally and mechanically protected\u003c\/li\u003e\n\u003cli\u003eIdeal for use in point-to-point runs in adverse environments\u003c\/li\u003e\n\u003cli\u003eDirect termination to subcable provides additional strain relief for better connector retention during moves, adds, and changes\u003c\/li\u003e\n\u003cli\u003eDesign is ideal for direct pulling with mesh grips\u003c\/li\u003e\n\u003cli\u003eCable materials are indoor\/outdoor - UV, water and fungus resistant\u003c\/li\u003e\n\u003cli\u003eWide operating temperature range of -40\u003cspan\u003eº\u003c\/span\u003eC to +85\u003cspan\u003eº\u003c\/span\u003eC\u003c\/li\u003e\n\u003cli\u003eHigh performance 900 _m tight buffered coating on each optical fiber for environmental and mechanical protection\u003c\/li\u003e\n\u003cli\u003eInterlocking armor can be applied to cables as an alternative to conduit installation\u003c\/li\u003e\n\u003cli\u003e2 to 72 fibers\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eIdeal for installations requiring an extremely rugged and reliable cable design where maximum mechanical and environmental protection are necessary\u003c\/li\u003e\n\u003cli\u003eEasiest cable to install where direct termination of connectors to sub-units and direct run to panels and equipment is desired\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eCost Savings\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eDirect termination to subcable may eliminate the need for patch panels and patch cords and reduces connector loss\u003c\/li\u003e\n\u003cli\u003e900 _m buffer eliminates the need for costly and time-consuming installation of fanout kits or pigtail splices because connectors terminate directly to the fiber\u003c\/li\u003e\n\u003cli\u003eHigh crush resistance may eliminate the need for innerduct\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eStandards List\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eUL 1651\u003c\/li\u003e\n\u003cli\u003eUL 1666\u003c\/li\u003e\n\u003cli\u003eGR-409-CORE\u003c\/li\u003e\n\u003cli\u003eICEA-S-104-696\u003c\/li\u003e\n\u003cli\u003eICEA-S-83-596\u003c\/li\u003e\n\u003cli\u003eTIA-568\u003c\/li\u003e\n\u003cli\u003eTIA-598\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eSpecifications\u003c\/h4\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0079\/8874\/0186\/files\/OCC_Breakout_OFNP_Specs.pdf?3934\" target=\"_blank\"\u003e \u003cbutton class=\"download-btn\"\u003eSpec Sheet\u003c\/button\u003e \u003c\/a\u003e \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0079\/8874\/0186\/files\/OCC-Ultra-Fox-perf_chart-1.pdf?1946\" target=\"_blank\"\u003e \u003cbutton class=\"download-btn\"\u003eFiber Performance Chart\u003c\/button\u003e \u003c\/a\u003e \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0079\/8874\/0186\/files\/OCC-Mil-Tac_Installation-General_Guidelines_Rev_B-1.pdf?3926\" target=\"_blank\"\u003e \u003cbutton class=\"download-btn\"\u003eGeneral Guidelines\u003c\/button\u003e \u003c\/a\u003e \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0079\/8874\/0186\/files\/OCC-Mil-Tac_Fiber_Optic_Field_Testing_Guidelines_Rev_A-1.pdf?3926\" target=\"_blank\"\u003e \u003cbutton class=\"download-btn\"\u003eTesting Guidelines\u003c\/button\u003e \u003c\/a\u003e \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0079\/8874\/0186\/files\/OCC-Mil-Tac_Storage_Handling_Rev_B-1.pdf?3926\" target=\"_blank\"\u003e \u003cbutton class=\"download-btn\"\u003eStorage Handling\u003c\/button\u003e \u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket Characteristics\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eOperating Temperature: -50ºC to +75ºC\u003c\/li\u003e\n\u003cli\u003eStorage Temperature: -55ºC to +85ºC\u003c\/li\u003e\n\u003cli\u003eInstallation Temperature: -30ºC to +60ºC\u003c\/li\u003e\n\u003cli\u003eFlame Retardancy: \u0026gt;UL Listed Type OFNR (UL 1666) and FT4 (CSA C22.2 No. 232)\u003c\/li\u003e\n\u003cli\u003eCrush Resistance: 2,200 N\/cm\u003c\/li\u003e\n\u003cli\u003eImpact Resistance: 1,500 impacts\u003c\/li\u003e\n\u003cli\u003eFlex Resistance: 2,000 cycles\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"OCC","offers":[{"title":"2 Strand","offer_id":30010554056749,"sku":"BX002DALT9QR","price":0.0,"currency_code":"USD","in_stock":true},{"title":"4 Strand","offer_id":31460786733117,"sku":"BX004DALT9QR","price":0.0,"currency_code":"USD","in_stock":true},{"title":"6 Strand","offer_id":31460788109373,"sku":"BX006DALT9QR","price":0.0,"currency_code":"USD","in_stock":true},{"title":"8 Strand","offer_id":31460788600893,"sku":"BX008DALT9QR","price":0.0,"currency_code":"USD","in_stock":true},{"title":"12 Strand","offer_id":31460789485629,"sku":"BX012DALT9QR","price":0.0,"currency_code":"USD","in_stock":true},{"title":"18 Strand","offer_id":31460791484477,"sku":"BX018DALT9QR","price":0.0,"currency_code":"USD","in_stock":true},{"title":"24 Strand","offer_id":31460792303677,"sku":"BX024DALT9QR","price":0.0,"currency_code":"USD","in_stock":true},{"title":"36 Strand","offer_id":31460794630205,"sku":"BX036DALT9QR","price":0.0,"currency_code":"USD","in_stock":true},{"title":"48 Strand","offer_id":31460795449405,"sku":"BX048DALT9QR","price":0.0,"currency_code":"USD","in_stock":true},{"title":"60 Strand","offer_id":31460795514941,"sku":"BX060DALT9QR","price":0.0,"currency_code":"USD","in_stock":true},{"title":"72 Strand","offer_id":31460795908157,"sku":"BX072DALT9QR","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0252\/1897\/3741\/products\/Breakout-IO_515x422_91754d9f-db83-475a-9909-c8f73f1c5852.png?v=1576623261"},{"product_id":"corning-freedm-one-dielectric-fiber-optic-cable-multimode-62-5125-om1-6-fiber-indooroutdoor-plenum-ofnp","title":"Corning FREEDM\" One Dielectric Fiber Optic Cable, Multimode, 62.5\/125 OM1, 6 Fiber, Indoor\/Outdoor, Plenum (OFNP)","description":"\u003cp\u003e\u003cimg height=\"75px\" width=\"55px\" class=\"bulleticons\" alt=\"RoHS Compliant\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0252\/1897\/3741\/files\/Bullets-_RoHS.jpg?2209\"\u003e \u003cimg style=\"background-color: #fff; border-radius: 10px; padding: 5px;\" height=\"65px\" width=\"170px\" alt=\"Made with Corning Glass\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0252\/1897\/3741\/files\/Bullets_PlusCorning.jpg?2209\"\u003e \u003cmeta charset=\"utf-8\"\u003e\u003c\/p\u003e\n\u003ch5\u003e(We do not offer credits or returns for this item.)\u003c\/h5\u003e\n\u003ch3\u003eCable is priced per foot with a minimum of 500ft.\u003c\/h3\u003e\n\u003ch5\u003eAn additional charge may apply for multiple cuts.\u003c\/h5\u003e\n\u003ch4\u003eDescription\u003c\/h4\u003e\n\u003ch2\u003eCorning FREEDM™ One Dielectric Fiber Optic Cable, Multimode, 62.5\/125 OM1, 6 Fiber, Indoor\/Outdoor, Plenum (OFNP)\u003c\/h2\u003e\n\u003cp\u003eCorning Cable Systems FREEDM™ One Cables are flame-retardant, UV-resistant, indoor\/outdoor cables designed for aerial, duct and direct-buried applications with no need for a transition splice when entering the building. The tight-buffered construction facilitates easier termination for low-fiber-count applications in the local area network (LAN) and eliminates need for fan-out kits. The design features TIA-598 color-coded 900 _m TBII™ Buffered Fibers for easy identification, consistent stripping and direct termination. The small diameter and bend radius of the cable allow for easy installation in space-constrained areas while the innovative water-blocking technology is ideal for OSP applications. The all-dielectric cable construction requires no grounding or bonding and the UV-resistant, flame-retardant jacket is rugged, durable and easy to strip\u003c\/p\u003e\n\u003cp\u003eThe colored jacket allows for easy visual identification of the cables while still providing all of the required environmental protection of an indoor\/outdoor cable jacket.\u003c\/p\u003e\n\u003cp\u003eCleaning your fiber connector end faces and components regularly is crucial for avoiding a total network failure. Ensure your optical fiber system is working properly and prevent major network issues with \u003ca alt=\"Fiber Cleaning Kits\" href=\"https:\/\/www.primuscable.com\/collections\/fiber-cleaning-kit\" target=\"_blank\"\u003e\u003cstrong\u003e fiber cleaning kits,\u003c\/strong\u003e\u003c\/a\u003e \u003ca alt=\"Fiber Cleaning Pens\" href=\"https:\/\/www.primuscable.com\/collections\/fiber-cleaning-pens\" target=\"_blank\"\u003e\u003cstrong\u003e pens,\u003c\/strong\u003e\u003c\/a\u003e\u003ca alt=\"Fiber Cleaning Fluids\" href=\"https:\/\/www.primuscable.com\/collections\/fiber-cleaning-fluids\" target=\"_blank\"\u003e\u003cstrong\u003e fluids,\u003c\/strong\u003e\u003c\/a\u003e and \u003ca alt=\"Fiber Cleaning Wipes\" href=\"https:\/\/www.primuscable.com\/collections\/fiber-cleaning-wipes\" target=\"_blank\"\u003e\u003cstrong\u003ewipes.\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003ch4\u003eFeatures\u003c\/h4\u003e\n\u003ch3\u003e\u003cspan style=\"text-decoration: underline;\"\u003eFeatures\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eWaterblocking Technology\u003c\/li\u003e\n\u003cli\u003eOSP (outdoor)\u003c\/li\u003e\n\u003cli\u003ePlenum (OFNP) Rated\u003c\/li\u003e\n\u003cli\u003eSmall Diameter \u0026amp; Bend Radius\u003c\/li\u003e\n\u003cli\u003eEasy Installation in Space-Constrained Areas\u003c\/li\u003e\n\u003cli\u003eColor Coded Fibers for Quick \u0026amp; Easy Identification\u003c\/li\u003e\n\u003cli\u003eAll-Dielectric Construction Requires No Grounding or Bonding\u003c\/li\u003e\n\u003cli\u003eRugged, Durable, Easy to Strip, UV-Resistant \u0026amp; Flame-Retardant Jacket\u003c\/li\u003e\n\u003cli\u003eRoHS Compliant\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eSpecifications\u003c\/h4\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0079\/8874\/0186\/files\/006K8P-31130-29_SpecSheet.pdf?1559\" target=\"_blank\"\u003e \u003cbutton class=\"download-btn\"\u003eSpec Sheet\u003c\/button\u003e \u003c\/a\u003e\u003c\/p\u003e","brand":"Corning","offers":[{"title":"Default Title","offer_id":30599773847597,"sku":"006K8P-31130-29","price":1.69,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0252\/1897\/3741\/products\/006K8P-31130-29_01.jpg?v=1567190846"},{"product_id":"duplex-fiber-optic-cable-zip-cord-multimode-50125-10-gig-om4-corning-fiber-indoor-riser","title":"Duplex Riser Fiber Optic Cable, Zip Cord, Multimode 10 Gig OM4, Corning Fiber, Indoor","description":"\u003cp\u003e\u003cimg style=\"background-color: #fff; border-radius: 10px; padding: 5px;\" height=\"65px\" width=\"115px\" alt=\"Made in USA\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0252\/1897\/3741\/files\/Made_In_USA.png?2208\"\u003e \u003cimg style=\"background-color: #fff; border-radius: 10px; padding: 5px;\" height=\"65px\" width=\"75px\" alt=\"UL Listed\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0252\/1897\/3741\/files\/UL_LISTED_LOGO_US.png?2209\"\u003e \u003cimg style=\"background-color: #fff; border-radius: 10px; padding: 5px;\" height=\"75px\" width=\"55px\" alt=\"RoHS Compliant\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0252\/1897\/3741\/files\/Bullets-_RoHS.jpg?2209\"\u003e \u003cimg style=\"background-color: #fff; border-radius: 10px; padding: 5px;\" height=\"65px\" width=\"170px\" alt=\"Made with Corning Glass\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0252\/1897\/3741\/files\/Bullets_PlusCorning.jpg?2209\"\u003e \u003cmeta charset=\"utf-8\"\u003e\u003c\/p\u003e\n\u003ch3\u003e(We do not offer credits or returns for this item.)\u003c\/h3\u003e\n\u003ch5\u003e\n\u003cb\u003eNote:\u003c\/b\u003e To request a quote email us or give us a call.\u003c\/h5\u003e\n\u003ch5\u003eIf you would like to inquire about our custom fiber cable options such as longer lengths, custom cut lengths, terminated ends, or pulleyes please call or email us.\u003c\/h5\u003e\n\u003ch4\u003eDescription\u003c\/h4\u003e\n\u003ch2\u003eDuplex CMR OM4 10G MultiMode Fiber Cable\u003c\/h2\u003e\n\u003cp\u003eThis Riser CMR Duplex 10G MultiMode OM4 50\/125 Fiber Cable is composed of a tight buffer, aramid yarn, and a PVC outer jacket. All component materials meet the EU RoHS and REACH Directive standards.\u003c\/p\u003e\n\u003cp\u003eThese riser duplex fiber cables are available in 12 TIA standard colors or special order colors. The fiber cable is UL Listed OFNR for use in vertical runs in building riser shafts or from floor to floor. Standard surface print denotes construction, NEC rating, and fiber type, and includes footage markers. Custom print can also be accommodated.\u003c\/p\u003e\n\u003cp\u003eCleaning your fiber connector end faces and components regularly is crucial for avoiding a total network failure. Ensure your optical fiber system is working properly and prevent major network issues with \u003ca alt=\"Fiber Cleaning Kits\" href=\"https:\/\/www.primuscable.com\/collections\/fiber-cleaning-kit\" target=\"_blank\"\u003e\u003cstrong\u003e fiber cleaning kits,\u003c\/strong\u003e\u003c\/a\u003e \u003ca alt=\"Fiber Cleaning Pens\" href=\"https:\/\/www.primuscable.com\/collections\/fiber-cleaning-pens\" target=\"_blank\"\u003e\u003cstrong\u003e pens,\u003c\/strong\u003e\u003c\/a\u003e\u003ca alt=\"Fiber Cleaning Fluids\" href=\"https:\/\/www.primuscable.com\/collections\/fiber-cleaning-fluids\" target=\"_blank\"\u003e\u003cstrong\u003e fluids,\u003c\/strong\u003e\u003c\/a\u003e and \u003ca alt=\"Fiber Cleaning Wipes\" href=\"https:\/\/www.primuscable.com\/collections\/fiber-cleaning-wipes\" target=\"_blank\"\u003e\u003cstrong\u003ewipes.\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003ch4\u003eFeatures\u003c\/h4\u003e\n\u003ch3\u003e\u003cspan style=\"text-decoration: underline;\"\u003eFeatures\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e3mm, 2mm, 1.8mm \u0026amp; 1.6mm OD sizes to meet all patch cord applications.\u003c\/li\u003e\n\u003cli\u003eConsistent 3.5lbs - 5lbs pull force for easy stripability.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003ePatch cord production.\u003c\/li\u003e\n\u003cli\u003eData centers.\u003c\/li\u003e\n\u003cli\u003eIndoor point to point connections.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eSpecifications\u003c\/h4\u003e\n\u003ch3\u003eTemperature Range\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eStorage Temperature: -40ºC to +70ºC\u003c\/li\u003e\n\u003cli\u003eOperating Temperature: -20ºC to +70ºC\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCable Characteristics\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eFiber Count: 2\u003c\/li\u003e\n\u003cli\u003eOuter Jacket Material: Flame Retardant PVC\u003c\/li\u003e\n\u003cli\u003eOuter Jacket Color: Aqua\u003c\/li\u003e\n\u003cli\u003eStrength Member: Aramid Yarn\u003c\/li\u003e\n\u003cli\u003eTight Buffer Material: Flame Retardant PVC\u003c\/li\u003e\n\u003cli\u003eTight Buffer Color: White \u0026amp; Aqua\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eMechanical Characteristics\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eNominal Outer Diameter\u003c\/li\u003e\n\u003cul\u003e\n\u003cli\u003e3.0 mm x 5.95\u003c\/li\u003e\n\u003cli\u003e2.0 mm x 3.95\u003c\/li\u003e\n\u003cli\u003e1.8 mm x 3.65\u003c\/li\u003e\n\u003cli\u003e1.6 mm x 3.25\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003eMinimum Bend Radius (Installation): 5 mm\/10 mm\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eOptical Characteristics\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eCore Size: 50 um\u003c\/li\u003e\n\u003cli\u003eWavelength: (850\/1300) nm\u003c\/li\u003e\n\u003cli\u003eMax. Attenuation: (3.5\/ 1.5) dB\/ km\u003c\/li\u003e\n\u003cli\u003eBandwidth (EMB) (High Performance): 4700 MHz @850nm\u003c\/li\u003e\n\u003cli\u003eLink Length (10GB\/s): 550 Meters\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eAdditional Information\u003c\/h4\u003e\n\u003cp\u003eMulti-Mode cable commonly has a diameter in the 50-to-100 micron range (typical multimode fiber core diameters are 50 or 62.5 micrometers). Multimode fiber gives you high bandwidth at high speeds (10 to 100MBS - Gigabit to 275m to 2km) over medium distances. Light waves are dispersed into numerous paths, or modes, as they travel through the cable's core typically 850 or 1300nm. However, in long cable runs (greater than 3000 feet [914.4 meters), multiple paths of light can cause signal distortion at the receiving end, resulting in an unclear and incomplete data transmission so designers now call for single mode fiber in new applications using Gigabit and beyond.\u003c\/p\u003e","brand":"Primus Cable","offers":[{"title":"3.0 mm","offer_id":30010619166765,"sku":"FB28-3798-MD3R","price":0.49,"currency_code":"USD","in_stock":true},{"title":"2.0 mm","offer_id":31454893867069,"sku":"FB28-3808-MD2R","price":0.49,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0252\/1897\/3741\/products\/Duplex-10G.png?v=1567190847"},{"product_id":"duplex-fiber-optic-cable-zip-cord-single-mode-9125-corning-fiber-indoor-plenum","title":"Duplex Plenum Fiber Optic Cable, Zip Cord, Single Mode, Corning Fiber, Indoor","description":"\u003cp\u003e\u003cimg style=\"background-color: #fff; border-radius: 10px; padding: 5px;\" height=\"65px\" width=\"115px\" alt=\"Made in USA\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0252\/1897\/3741\/files\/Made_In_USA.png?2208\"\u003e \u003cimg style=\"background-color: #fff; border-radius: 10px; padding: 5px;\" height=\"65px\" width=\"75px\" alt=\"UL Listed\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0252\/1897\/3741\/files\/UL_LISTED_LOGO_US.png?2209\"\u003e \u003cimg style=\"background-color: #fff; border-radius: 10px; padding: 5px;\" height=\"75px\" width=\"55px\" alt=\"RoHS Compliant\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0252\/1897\/3741\/files\/Bullets-_RoHS.jpg?2209\"\u003e \u003cimg style=\"background-color: #fff; border-radius: 10px; padding: 5px;\" height=\"65px\" width=\"170px\" alt=\"Made with Corning Glass\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0252\/1897\/3741\/files\/Bullets_PlusCorning.jpg?2209\"\u003e \u003cmeta charset=\"utf-8\"\u003e\u003c\/p\u003e\n\u003ch3\u003e(We do not offer credits or returns for this item.)\u003c\/h3\u003e\n\u003ch5\u003e\n\u003cb\u003eNote:\u003c\/b\u003e To request a quote email us or give us a call.\u003c\/h5\u003e\n\u003ch5\u003eIf you would like to inquire about our custom fiber cable options such as longer lengths, custom cut lengths, terminated ends, or pulleyes please call or email us.\u003c\/h5\u003e\n\u003ch4\u003eDescription\u003c\/h4\u003e\n\u003ch2\u003eDuplex CMP OS2 Single Mode Fiber Cable\u003c\/h2\u003e\n\u003cp\u003ePlenum CMP Duplex OS2 Single Mode 9\/125 Fiber Cable is composed of a tight buffer, aramid yarn, and a PVC outer jacket. All component materials meet the EU RoHS and REACH Directive standards.\u003c\/p\u003e\n\u003cp\u003eThese plenum duplex fiber cables are available in 12 TIA standard colors or special order colors. The fiber cable is UL Listed OFNP for use in ducts, plenums and air-handling spaces. Standard surface print denotes construction, NEC rating, and fiber type, and includes footage markers. Custom print can also be accommodated.\u003c\/p\u003e\n\u003cp\u003eCleaning your fiber connector end faces and components regularly is crucial for avoiding a total network failure. Ensure your optical fiber system is working properly and prevent major network issues with \u003ca alt=\"Fiber Cleaning Kits\" href=\"https:\/\/www.primuscable.com\/collections\/fiber-cleaning-kit\" target=\"_blank\"\u003e\u003cstrong\u003e fiber cleaning kits,\u003c\/strong\u003e\u003c\/a\u003e \u003ca alt=\"Fiber Cleaning Pens\" href=\"https:\/\/www.primuscable.com\/collections\/fiber-cleaning-pens\" target=\"_blank\"\u003e\u003cstrong\u003e pens,\u003c\/strong\u003e\u003c\/a\u003e\u003ca alt=\"Fiber Cleaning Fluids\" href=\"https:\/\/www.primuscable.com\/collections\/fiber-cleaning-fluids\" target=\"_blank\"\u003e\u003cstrong\u003e fluids,\u003c\/strong\u003e\u003c\/a\u003e and \u003ca alt=\"Fiber Cleaning Wipes\" href=\"https:\/\/www.primuscable.com\/collections\/fiber-cleaning-wipes\" target=\"_blank\"\u003e\u003cstrong\u003ewipes.\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003ch4\u003eFeatures\u003c\/h4\u003e\n\u003ch3\u003e\u003cspan style=\"text-decoration: underline;\"\u003eFeatures\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e3mm, 2mm, 1.8mm \u0026amp; 1.6mm OD sizes to meet all patch cord applications.\u003c\/li\u003e\n\u003cli\u003eConsistent 3.5lbs - 5lbs pull force for easy stripability.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003ePatch cord production.\u003c\/li\u003e\n\u003cli\u003eData centers.\u003c\/li\u003e\n\u003cli\u003eIndoor point to point connections.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eSpecifications\u003c\/h4\u003e\n\u003ch3\u003eTemperature Range\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eStorage Temperature: -40ºC to +70ºC\u003c\/li\u003e\n\u003cli\u003eOperating Temperature: -20ºC to +70ºC\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCable Characteristics\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eFiber Count: 2\u003c\/li\u003e\n\u003cli\u003eOuter Jacket Material: Flame Retardant PVC\u003c\/li\u003e\n\u003cli\u003eOuter Jacket Color: Yellow\u003c\/li\u003e\n\u003cli\u003eStrength Member: Aramid Yarn\u003c\/li\u003e\n\u003cli\u003eTight Buffer Material: Flame Retardant PVC\u003c\/li\u003e\n\u003cli\u003eTight Buffer Color: Blue \u0026amp; Orange\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eMechanical Characteristics\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eNominal Outer Diameter\u003c\/li\u003e\n\u003cul\u003e\n\u003cli\u003e3.0 mm x 5.95\u003c\/li\u003e\n\u003cli\u003e2.0 mm x 3.95\u003c\/li\u003e\n\u003cli\u003e1.8 mm x 3.65\u003c\/li\u003e\n\u003cli\u003e1.6 mm x 3.25\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003eMinimum Bend Radius (mm) (Bend Insensitive SM) 5\/ 10\u003c\/li\u003e\n\u003cli\u003eMinimum Bend Radius (mm) (SM) 1 turn\/100 turns 32\/ 50\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eOptical Characteristics\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eCore Size: 9 um\u003c\/li\u003e\n\u003cli\u003eWavelength: (1310\/1550) nm\u003c\/li\u003e\n\u003cli\u003eMax. Attenuation: (0.5\/0.4) dB\/km\u003c\/li\u003e\n\u003cli\u003eBandwidth (EMB) (High Performance): N\/A\u003c\/li\u003e\n\u003cli\u003eLink Length (10GB\/s): N\/A\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eAdditional Information\u003c\/h4\u003e\n\u003cp\u003eSingle mode fiber cable (Synonyms mono-mode optical fiber, single-mode fiber, single-mode optical waveguide, uni-mode fiber) is a single strand of glass fiber with a diameter of 8.3 to 10 microns that has one mode of transmission. Single mode fiber has a relatively narrow diameter, through which only one mode will propagate typically 1310 or 1550nm wavelengths. Single mode fibers carry higher bandwidth than multimode fiber, but require a light source with a narrow spectral width. Single-mode fiber gives you a higher transmission rate and up to 50 times more distance than multimode. The small core and single light-wave virtually eliminate any distortion that could result from overlapping light pulses, providing the least signal attenuation and the highest transmission speeds of any fiber cable type.\u003c\/p\u003e","brand":"Primus Cable","offers":[{"title":"3.0 mm","offer_id":31316677296189,"sku":"FB29-3799-SD3P","price":0.24,"currency_code":"USD","in_stock":true},{"title":"2.0 mm","offer_id":30010619265069,"sku":"FB29-3809-SD2P","price":0.24,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0252\/1897\/3741\/products\/Duplex-SM.png?v=1567190847"},{"product_id":"simplex-fiber-optic-cable-multimode-50125-10-gig-om4-corning-fiber-indoor-plenum","title":"Simplex Plenum, Fiber Optic Cable, Multimode, 10 Gig OM4, Corning Fiber, Indoor","description":"\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0252\/1897\/3741\/files\/Made_In_USA.png?2208\" alt=\"Made in USA\" width=\"115px\" height=\"65px\" style=\"background-color: #fff; border-radius: 10px; padding: 5px;\"\u003e \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0252\/1897\/3741\/files\/UL_LISTED_LOGO_US.png?2209\" alt=\"UL Listed\" width=\"75px\" height=\"65px\" style=\"background-color: #fff; border-radius: 10px; padding: 5px;\"\u003e \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0252\/1897\/3741\/files\/Bullets-_RoHS.jpg?2209\" alt=\"RoHS Compliant\" width=\"55px\" height=\"75px\" style=\"background-color: #fff; border-radius: 10px; padding: 5px;\"\u003e \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0252\/1897\/3741\/files\/Bullets_PlusCorning.jpg?2209\" alt=\"Made with Corning Glass\" width=\"170px\" height=\"65px\" style=\"background-color: #fff; border-radius: 10px; padding: 5px;\"\u003e \u003cbr\u003e\u003cmeta charset=\"utf-8\"\u003e\u003c\/p\u003e\n\u003ch3\u003e(We do not offer credits or returns for this item.)\u003cbr\u003eMinimum and Maximum Order Lengths for Non-Freight Shipments:\u003c\/h3\u003e\n\u003ctable width=\"100%\" border=\"1px\" style=\"border: solid medium;\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: solid thin;\" bgcolor=\"#999999\"\u003e \u003c\/td\u003e\n\u003ctd style=\"border: solid thin;\" bgcolor=\"#FFE800\" align=\"center\"\u003e\u003cb\u003e3.0mm\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"border: solid thin;\" bgcolor=\"#FFE800\" align=\"center\"\u003e\u003cb\u003e2.0mm\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"border: solid thin;\" bgcolor=\"#FFE800\" align=\"center\"\u003e\u003cb\u003e1.6mm\u003c\/b\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: solid thin;\" bgcolor=\"#FF6F00\" align=\"center\"\u003e\u003cb\u003eMin.\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"border: solid thin;\" align=\"center\"\u003e1,000ft. (304m)\u003c\/td\u003e\n\u003ctd style=\"border: solid thin;\" align=\"center\"\u003e3,500ft. (1067m)\u003c\/td\u003e\n\u003ctd style=\"border: solid thin;\" align=\"center\"\u003e3,250ft. (991m)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: solid thin;\" bgcolor=\"#FF6F00\" align=\"center\"\u003e\u003cb\u003eMax.\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"border: solid thin;\" align=\"center\"\u003e13,000ft. (3962m)\u003c\/td\u003e\n\u003ctd style=\"border: solid thin;\" align=\"center\"\u003e16,900ft. (4876m)\u003c\/td\u003e\n\u003ctd style=\"border: solid thin;\" align=\"center\"\u003e16,000ft. (4876m)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch5\u003e\n\u003cb\u003eNote:\u003c\/b\u003e To request a quote email us or give us a call.\u003c\/h5\u003e\n\u003ch5\u003eIf you would like to inquire about our custom fiber cable options such as longer lengths, custom cut lengths, terminated ends, or pulleyes please call or email us.\u003c\/h5\u003e\n\u003ch4\u003eDescription\u003c\/h4\u003e\n\u003ch2\u003eSimplex CMP OM4 Multimode Cable\u003c\/h2\u003e\n\u003cp\u003eSimplex Plenum OM4 10G MultiMode 50\/125 Fiber Cable is composed of a tight buffer, aramid yarn, and a PVC outer jacket. All component materials meet the EU RoHS and REACH Directive standards.\u003c\/p\u003e\n\u003cp\u003eThese plenum simplex fiber cables are available in 12 TIA standard colors or special order colors. The fiber cable is UL Listed OFNP for use in ducts, plenums and air-handling spaces. Standard surface print denotes construction, NEC rating, and fiber type, and includes footage markers. Available outer diameter sizes include 3 mm, 2 mm, 1.8 mm and 1.6 mm.\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eCleaning your fiber connector end faces and components regularly is crucial for avoiding a total network failure. Ensure your optical fiber system is working properly and prevent major network issues with \u003c\/span\u003e\u003ca href=\"https:\/\/www.primuscable.com\/collections\/fiber-cleaning-kit\" alt=\"Fiber Cleaning Kits\" target=\"_blank\"\u003efiber cleaning kits,\u003c\/a\u003e \u003ca href=\"https:\/\/www.primuscable.com\/collections\/fiber-cleaning-pens\" alt=\"Fiber Cleaning Pens\" target=\"_blank\"\u003epens,\u003c\/a\u003e\u003ca href=\"https:\/\/www.primuscable.com\/collections\/fiber-cleaning-fluids\" alt=\"Fiber Cleaning Fluids\" target=\"_blank\"\u003e fluids,\u003c\/a\u003e and \u003ca href=\"https:\/\/www.primuscable.com\/collections\/fiber-cleaning-wipes\" alt=\"Fiber Cleaning Wipes\" target=\"_blank\"\u003ewipes.\u003c\/a\u003e\u003c\/p\u003e\n\u003ch4\u003eFeatures\u003c\/h4\u003e\n\u003ch3\u003e\u003cspan style=\"text-decoration: underline;\"\u003eFeatures\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e3 mm, 2 mm, 1.8 mm \u0026amp; 1.6 mm OD sizes to meet all patch cord applications.\u003c\/li\u003e\n\u003cli\u003eConsistent 3.5lbs - 5lbs pull force for easy strip-ability.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eApplications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003ePatch cord production.\u003c\/li\u003e\n\u003cli\u003eData centers.\u003c\/li\u003e\n\u003cli\u003eIndoor point to point connections.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eSpecifications\u003c\/h4\u003e\n\u003ch2\u003eTemperature Range\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eStorage Temperature: -40ºC to +70ºC\u003c\/li\u003e\n\u003cli\u003eOperating Temperature: -20ºC to +70ºC\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCable Characteristics\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eFiber Count: 1\u003c\/li\u003e\n\u003cli\u003eOuter Jacket Material: Flame Retardant PVC\u003c\/li\u003e\n\u003cli\u003eOuter Jacket Color: Aqua\u003c\/li\u003e\n\u003cli\u003eStrength Member: Aramid Yarn\u003c\/li\u003e\n\u003cli\u003eTight Buffer Material: Flame Retardant PVC\u003c\/li\u003e\n\u003cli\u003eTight Buffer Color: White\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eMechanical Characteristics\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eNominal Outer Diameter\u003c\/li\u003e\n\u003cul\u003e\n\u003cli\u003e3 mm\u003c\/li\u003e\n\u003cli\u003e2 mm\u003c\/li\u003e\n\u003cli\u003e1.80 mm\u003c\/li\u003e\n\u003cli\u003e1.60 mm\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003eMinimum Bend Radius (Bend Insensitive MM): 7.5 mm\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eOptical Characteristics\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eCore Size: 50 um\u003c\/li\u003e\n\u003cli\u003eWavelength: (850\/ 1300) nm\u003c\/li\u003e\n\u003cli\u003eMax. Attenuation: (3.5\/ 1.5) dB\/ km\u003c\/li\u003e\n\u003cli\u003eBandwidth (EMB) (High Performance): 4700 MHz @850nm\u003c\/li\u003e\n\u003cli\u003eLink Length (10GB\/s): 550 Meters\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eAdditional Information\u003c\/h4\u003e\n\u003cp\u003eMulti-Mode cable commonly has a diameter in the 50-to-100 micron range (typical multimode fiber core diameters are 50 or 62.5 micrometers). Multimode fiber gives you high bandwidth at high speeds (10 to 100MBS - Gigabit to 275m to 2km) over medium distances. Light waves are dispersed into numerous paths, or modes, as they travel through the cable's core typically 850 or 1300nm. However, in long cable runs (greater than 3000 feet [914.4 meters), multiple paths of light can cause signal distortion at the receiving end, resulting in an unclear and incomplete data transmission so designers now call for single mode fiber in new applications using Gigabit and beyond.\u003c\/p\u003e","brand":"Primus Cable","offers":[{"title":"1.6 mm","offer_id":31454156587069,"sku":"FB31-####-MS16P","price":0.0,"currency_code":"USD","in_stock":true},{"title":"1.8 mm","offer_id":31454155735101,"sku":"FB31-####-MS18P","price":0.0,"currency_code":"USD","in_stock":true},{"title":"2.0 mm","offer_id":31454153539645,"sku":"FB31-3832-MS2P","price":0.0,"currency_code":"USD","in_stock":true},{"title":"3.0 mm","offer_id":30010831339565,"sku":"FB31-3823-MS3P","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0252\/1897\/3741\/products\/Simplex-10G_0af87ee6-58bd-4c9f-9782-fcb5e59eee40.png?v=1567190847"},{"product_id":"duplex-fiber-optic-cable-zip-cord-single-mode-9125-corning-fiber-indoor-riser","title":"Duplex Riser Fiber Optic Cable, Zip Cord, Single Mode, Corning Fiber, Indoor","description":"\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0252\/1897\/3741\/files\/Made_In_USA.png?2208\" alt=\"Made in USA\" width=\"115px\" height=\"65px\" style=\"background-color: #fff; border-radius: 10px; padding: 5px;\"\u003e \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0252\/1897\/3741\/files\/UL_LISTED_LOGO_US.png?2209\" alt=\"UL Listed\" width=\"75px\" height=\"65px\" style=\"background-color: #fff; border-radius: 10px; padding: 5px;\"\u003e \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0252\/1897\/3741\/files\/Bullets-_RoHS.jpg?2209\" alt=\"RoHS Compliant\" width=\"55px\" height=\"75px\" style=\"background-color: #fff; border-radius: 10px; padding: 5px;\"\u003e \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0252\/1897\/3741\/files\/Bullets_PlusCorning.jpg?2209\" alt=\"Made with Corning Glass\" width=\"170px\" height=\"65px\" style=\"background-color: #fff; border-radius: 10px; padding: 5px;\"\u003e \u003cmeta charset=\"utf-8\"\u003e\u003c\/p\u003e\n\u003ch3\u003e(We do not offer credits or returns for this item.)\u003c\/h3\u003e\n\u003ch5\u003e\n\u003cb\u003eNote:\u003c\/b\u003e To request a quote email us or give us a call.\u003c\/h5\u003e\n\u003ch5\u003eIf you would like to inquire about our custom fiber cable options such as longer lengths, custom cut lengths, terminated ends, or pulleyes please call or email us.\u003c\/h5\u003e\n\u003ch4\u003eDescription\u003c\/h4\u003e\n\u003ch2\u003eDuplex CMR OS2 Single Mode Fiber Cable\u003c\/h2\u003e\n\u003cp\u003eThis Riser CMR Duplex Single Mode OS2 Fiber Cable is composed of a tight buffer, aramid yarn, and a PVC outer jacket. All component materials meet the EU RoHS and REACH Directive standards.\u003c\/p\u003e\n\u003cp\u003eThese riser duplex fiber cables are available in 12 TIA standard colors or special order colors. The fiber cable is UL Listed OFNR for use in vertical runs in building riser shafts or from floor to floor. Standard surface print denotes construction, NEC rating, and fiber type, and includes footage markers. Custom print can also be accommodated.\u003c\/p\u003e\n\u003cp\u003eCleaning your fiber connector end faces and components regularly is crucial for avoiding a total network failure. Ensure your optical fiber system is working properly and prevent major network issues with \u003ca href=\"https:\/\/www.primuscable.com\/collections\/fiber-cleaning-kit\" alt=\"Fiber Cleaning Kits\" target=\"_blank\"\u003e\u003cstrong\u003e fiber cleaning kits,\u003c\/strong\u003e\u003c\/a\u003e \u003ca href=\"https:\/\/www.primuscable.com\/collections\/fiber-cleaning-pens\" alt=\"Fiber Cleaning Pens\" target=\"_blank\"\u003e\u003cstrong\u003e pens,\u003c\/strong\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/www.primuscable.com\/collections\/fiber-cleaning-fluids\" alt=\"Fiber Cleaning Fluids\" target=\"_blank\"\u003e\u003cstrong\u003e fluids,\u003c\/strong\u003e\u003c\/a\u003e and \u003ca href=\"https:\/\/www.primuscable.com\/collections\/fiber-cleaning-wipes\" alt=\"Fiber Cleaning Wipes\" target=\"_blank\"\u003e\u003cstrong\u003ewipes.\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003ch4\u003eFeatures\u003c\/h4\u003e\n\u003ch3\u003e\u003cspan style=\"text-decoration: underline;\"\u003eFeatures\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e3mm, 2mm, 1.8mm \u0026amp; 1.6mm OD sizes to meet all patch cord applications.\u003c\/li\u003e\n\u003cli\u003eConsistent 3.5lbs - 5lbs pull force for easy stripability.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003ePatch cord production.\u003c\/li\u003e\n\u003cli\u003eData centers.\u003c\/li\u003e\n\u003cli\u003eIndoor point to point connections.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eSpecifications\u003c\/h4\u003e\n\u003ch3\u003eTemperature Range\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eStorage Temperature: -40ºC to +70ºC\u003c\/li\u003e\n\u003cli\u003eOperating Temperature: -20ºC to +70ºC\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCable Characteristics\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eFiber Count: 2\u003c\/li\u003e\n\u003cli\u003eOuter Jacket Material: Flame Retardant PVC\u003c\/li\u003e\n\u003cli\u003eOuter Jacket Color: Yellow\u003c\/li\u003e\n\u003cli\u003eStrength Member: Aramid Yarn\u003c\/li\u003e\n\u003cli\u003eTight Buffer Material: Flame Retardant PVC\u003c\/li\u003e\n\u003cli\u003eTight Buffer Color: Blue \u0026amp; Orange\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eMechanical Characteristics\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eNominal Outer Diameter\u003c\/li\u003e\n\u003cul\u003e\n\u003cli\u003e3.0 mm x 5.95\u003c\/li\u003e\n\u003cli\u003e2.0 mm x 3.95\u003c\/li\u003e\n\u003cli\u003e1.8 mm x 3.65\u003c\/li\u003e\n\u003cli\u003e1.6 mm x 3.25\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003eMinimum Bend Radius (Installation): 5 mm\/10 mm\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eOptical Characteristics\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eCore Size: 9 um\u003c\/li\u003e\n\u003cli\u003eWavelength: (1310\/1550) nm\u003c\/li\u003e\n\u003cli\u003eMax. Attenuation: (0.5\/0.4) dB\/km\u003c\/li\u003e\n\u003cli\u003eBandwidth (EMB) (High Performance): N\/A\u003c\/li\u003e\n\u003cli\u003eLink Length (10GB\/s): N\/A\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eAdditional Information\u003c\/h4\u003e\n\u003ch3\u003e\u003cbr\u003e\u003c\/h3\u003e\n\u003cp\u003eSingle mode fiber cable (Synonyms mono-mode optical fiber, single-mode fiber, single-mode optical waveguide, uni-mode fiber) is a single strand of glass fiber with a diameter of 8.3 to 10 microns that has one mode of transmission. Single mode fiber has a relatively narrow diameter, through which only one mode will propagate typically 1310 or 1550nm wavelengths. Single mode fibers carry higher bandwidth than multimode fiber, but require a light source with a narrow spectral width. Single-mode fiber gives you a higher transmission rate and up to 50 times more distance than multimode. The small core and single light-wave virtually eliminate any distortion that could result from overlapping light pulses, providing the least signal attenuation and the highest transmission speeds of any fiber cable type.\u003c\/p\u003e","brand":"Primus Cable","offers":[{"title":"3.0 mm","offer_id":30010619428909,"sku":"FB28-3794-SD3R","price":0.23,"currency_code":"USD","in_stock":true},{"title":"2.0 mm","offer_id":31454456905789,"sku":"FB28-3804-SD2R","price":0.23,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0252\/1897\/3741\/products\/Duplex-SM_fd21e262-cc76-48c1-a071-44997834549e.png?v=1567190847"},{"product_id":"duplex-fiber-optic-cable-zip-cord-multimode-50125-10-gig-om3-corning-fiber-indoor-riser","title":"Duplex Riser Fiber Optic Cable, Zip Cord, Multimode 10 Gig OM3, Corning Fiber, Indoor","description":"\u003cp\u003e\u003cimg style=\"background-color: #fff; border-radius: 10px; padding: 5px;\" height=\"65px\" width=\"115px\" alt=\"Made in USA\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0252\/1897\/3741\/files\/Made_In_USA.png?2208\"\u003e \u003cimg style=\"background-color: #fff; border-radius: 10px; padding: 5px;\" height=\"65px\" width=\"75px\" alt=\"UL Listed\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0252\/1897\/3741\/files\/UL_LISTED_LOGO_US.png?2209\"\u003e \u003cimg style=\"background-color: #fff; border-radius: 10px; padding: 5px;\" height=\"75px\" width=\"55px\" alt=\"RoHS Compliant\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0252\/1897\/3741\/files\/Bullets-_RoHS.jpg?2209\"\u003e \u003cimg style=\"background-color: #fff; border-radius: 10px; padding: 5px;\" height=\"65px\" width=\"170px\" alt=\"Made with Corning Glass\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0252\/1897\/3741\/files\/Bullets_PlusCorning.jpg?2209\"\u003e \u003cmeta charset=\"utf-8\"\u003e\u003c\/p\u003e\n\u003ch3\u003e(We do not offer credits or returns for this item.)\u003c\/h3\u003e\n\u003ch5\u003e\n\u003cb\u003eNote:\u003c\/b\u003e To request a quote email us or give us a call.\u003c\/h5\u003e\n\u003ch5\u003eIf you would like to inquire about our custom fiber cable options such as longer lengths, custom cut lengths, terminated ends, or pulleyes please call or email us.\u003c\/h5\u003e\n\u003ch4\u003eDescription\u003c\/h4\u003e\n\u003ch2\u003eDuplex CMR OM3 10G MultiMode Fiber Cable\u003c\/h2\u003e\n\u003cp\u003eThis Riser CMR Duplex 10G MultiMode OM3 50\/125 Fiber Cable is composed of a tight buffer, aramid yarn, and a PVC outer jacket. All component materials meet the EU RoHS and REACH Directive standards.\u003c\/p\u003e\n\u003cp\u003eThese riser duplex fiber cables are available in 12 TIA standard colors or special order colors. The fiber cable is UL Listed OFNR for use in vertical runs in building riser shafts or from floor to floor. Standard surface print denotes construction, NEC rating, and fiber type, and includes footage markers. Custom print can also be accommodated.\u003c\/p\u003e\n\u003cp\u003eCleaning your fiber connector end faces and components regularly is crucial for avoiding a total network failure. Ensure your optical fiber system is working properly and prevent major network issues with \u003ca alt=\"Fiber Cleaning Kits\" href=\"https:\/\/www.primuscable.com\/collections\/fiber-cleaning-kit\" target=\"_blank\"\u003e\u003cstrong\u003e fiber cleaning kits,\u003c\/strong\u003e\u003c\/a\u003e \u003ca alt=\"Fiber Cleaning Pens\" href=\"https:\/\/www.primuscable.com\/collections\/fiber-cleaning-pens\" target=\"_blank\"\u003e\u003cstrong\u003e pens,\u003c\/strong\u003e\u003c\/a\u003e\u003ca alt=\"Fiber Cleaning Fluids\" href=\"https:\/\/www.primuscable.com\/collections\/fiber-cleaning-fluids\" target=\"_blank\"\u003e\u003cstrong\u003e fluids,\u003c\/strong\u003e\u003c\/a\u003e and \u003ca alt=\"Fiber Cleaning Wipes\" href=\"https:\/\/www.primuscable.com\/collections\/fiber-cleaning-wipes\" target=\"_blank\"\u003e\u003cstrong\u003ewipes.\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003ch4\u003eFeatures\u003c\/h4\u003e\n\u003ch3\u003e\u003cspan style=\"text-decoration: underline;\"\u003eFeatures\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e3mm, 2mm, 1.8mm \u0026amp; 1.6mm OD sizes to meet all patch cord applications.\u003c\/li\u003e\n\u003cli\u003eConsistent 3.5lbs - 5lbs pull force for easy stripability.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cb\u003eApplications\u003c\/b\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003ePatch cord production.\u003c\/li\u003e\n\u003cli\u003eData centers.\u003c\/li\u003e\n\u003cli\u003eIndoor point to point connections.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eSpecifications\u003c\/h4\u003e\n\u003cp\u003e\u003cb\u003eTemperature Range\u003c\/b\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eStorage Temperature: -40ºC to +70ºC\u003c\/li\u003e\n\u003cli\u003eOperating Temperature: -20ºC to +70ºC\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cb\u003eCable Characteristics\u003c\/b\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eFiber Count: 2\u003c\/li\u003e\n\u003cli\u003eOuter Jacket Material: Flame Retardant PVC\u003c\/li\u003e\n\u003cli\u003eOuter Jacket Color: Aqua\u003c\/li\u003e\n\u003cli\u003eStrength Member: Aramid Yarn\u003c\/li\u003e\n\u003cli\u003eTight Buffer Material: Flame Retardant PVC\u003c\/li\u003e\n\u003cli\u003eTight Buffer Color: White \u0026amp; Aqua\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cb\u003eMechanical Characteristics\u003c\/b\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eNominal Outer Diameter\u003c\/li\u003e\n\u003cul\u003e\n\u003cli\u003e3.0 mm x 5.95\u003c\/li\u003e\n\u003cli\u003e2.0 mm x 3.95\u003c\/li\u003e\n\u003cli\u003e1.8 mm x 3.65\u003c\/li\u003e\n\u003cli\u003e1.6 mm x 3.25\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003eMinimum Bend Radius (Installation): 5 mm\/10 mm\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cb\u003eOptical Characteristics\u003c\/b\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eCore Size: 50 um\u003c\/li\u003e\n\u003cli\u003eWavelength: (850\/1300) nm\u003c\/li\u003e\n\u003cli\u003eMax. Attenuation: (3.5\/ 1.5) dB\/ km\u003c\/li\u003e\n\u003cli\u003eBandwidth (EMB) (High Performance): 2000 MHz @850nm\u003c\/li\u003e\n\u003cli\u003eLink Length (10GB\/s): 300 Meters\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eAdditional Information\u003c\/h4\u003e\n\u003cp\u003eMulti-Mode cable commonly has a diameter in the 50-to-100 micron range (typical multimode fiber core diameters are 50 or 62.5 micrometers). Multimode fiber gives you high bandwidth at high speeds (10 to 100MBS - Gigabit to 275m to 2km) over medium distances. Light waves are dispersed into numerous paths, or modes, as they travel through the cable's core typically 850 or 1300nm. However, in long cable runs (greater than 3000 feet [914.4 meters), multiple paths of light can cause signal distortion at the receiving end, resulting in an unclear and incomplete data transmission so designers now call for single mode fiber in new applications using Gigabit and beyond.\u003c\/p\u003e","brand":"Primus Cable","offers":[{"title":"3.0 mm","offer_id":30010619101229,"sku":"FB28-3797-MD3R","price":0.4,"currency_code":"USD","in_stock":true},{"title":"2.0 mm","offer_id":31454858117181,"sku":"FB28-3807-MD2R","price":0.4,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0252\/1897\/3741\/products\/Duplex-10G_ed67be4c-759a-4ce9-b3d7-3f84aa60745d.png?v=1567190848"},{"product_id":"duplex-fiber-optic-cable-zip-cord-multimode-62-5125-om1-corning-fiber-indoor-riser","title":"Duplex Riser Fiber Optic Cable, Zip Cord, Multimode OM1, Corning Fiber, Indoor","description":"\u003cp\u003e\u003cimg style=\"background-color: #fff; border-radius: 10px; padding: 5px;\" height=\"65px\" width=\"115px\" alt=\"Made in USA\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0252\/1897\/3741\/files\/Made_In_USA.png?2208\"\u003e \u003cimg style=\"background-color: #fff; border-radius: 10px; padding: 5px;\" height=\"65px\" width=\"75px\" alt=\"UL Listed\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0252\/1897\/3741\/files\/UL_LISTED_LOGO_US.png?2209\"\u003e \u003cimg style=\"background-color: #fff; border-radius: 10px; padding: 5px;\" height=\"75px\" width=\"55px\" alt=\"RoHS Compliant\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0252\/1897\/3741\/files\/Bullets-_RoHS.jpg?2209\"\u003e \u003cimg style=\"background-color: #fff; border-radius: 10px; padding: 5px;\" height=\"65px\" width=\"170px\" alt=\"Made with Corning Glass\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0252\/1897\/3741\/files\/Bullets_PlusCorning.jpg?2209\"\u003e \u003cmeta charset=\"utf-8\"\u003e\u003c\/p\u003e\n\u003ch3\u003e(We do not offer credits or returns for this item.)\u003c\/h3\u003e\n\u003ch5\u003e\n\u003cb\u003eNote:\u003c\/b\u003e To request a quote email us or give us a call.\u003c\/h5\u003e\n\u003ch5\u003eIf you would like to inquire about our custom fiber cable options such as longer lengths, custom cut lengths, terminated ends, or pulleyes please call or email us.\u003c\/h5\u003e\n\u003ch4\u003eDescription\u003c\/h4\u003e\n\u003ch2\u003eDuplex CMR OM1 MultiMode Fiber Cable\u003c\/h2\u003e\n\u003cp\u003eThis Riser CMR Duplex MultiMode OM1 Fiber Cable is composed of a tight buffer, aramid yarn, and a PVC outer jacket. All component materials meet the EU RoHS and REACH Directive standards.\u003c\/p\u003e\n\u003cp\u003eThese riser duplex fiber cables are available in 12 TIA standard colors or special order colors. The fiber cable is UL Listed OFNR for use in vertical runs in building riser shafts or from floor to floor. Standard surface print denotes construction, NEC rating, and fiber type, and includes footage markers. Custom print can also be accommodated.\u003c\/p\u003e\n\u003cp\u003eCleaning your fiber connector end faces and components regularly is crucial for avoiding a total network failure. Ensure your optical fiber system is working properly and prevent major network issues with \u003ca alt=\"Fiber Cleaning Kits\" href=\"https:\/\/www.primuscable.com\/collections\/fiber-cleaning-kit\" target=\"_blank\"\u003e\u003cstrong\u003e fiber cleaning kits,\u003c\/strong\u003e\u003c\/a\u003e \u003ca alt=\"Fiber Cleaning Pens\" href=\"https:\/\/www.primuscable.com\/collections\/fiber-cleaning-pens\" target=\"_blank\"\u003e\u003cstrong\u003e pens,\u003c\/strong\u003e\u003c\/a\u003e\u003ca alt=\"Fiber Cleaning Fluids\" href=\"https:\/\/www.primuscable.com\/collections\/fiber-cleaning-fluids\" target=\"_blank\"\u003e\u003cstrong\u003e fluids,\u003c\/strong\u003e\u003c\/a\u003e and \u003ca alt=\"Fiber Cleaning Wipes\" href=\"https:\/\/www.primuscable.com\/collections\/fiber-cleaning-wipes\" target=\"_blank\"\u003e\u003cstrong\u003ewipes.\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003ch4\u003eFeatures\u003c\/h4\u003e\n\u003ch3\u003e\u003cspan style=\"text-decoration: underline;\"\u003eFeatures\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e3mm, 2mm, 1.8mm \u0026amp; 1.6mm OD sizes to meet all patch cord applications.\u003c\/li\u003e\n\u003cli\u003eConsistent 3.5lbs - 5lbs pull force for easy stripability.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003ePatch cord production.\u003c\/li\u003e\n\u003cli\u003eData centers.\u003c\/li\u003e\n\u003cli\u003eIndoor point to point connections.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eSpecifications\u003c\/h4\u003e\n\u003ch3\u003eTemperature Range\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eStorage Temperature: -40ºC to +70ºC\u003c\/li\u003e\n\u003cli\u003eOperating Temperature: -20ºC to +70ºC\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCable Characteristics\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eFiber Count: 2\u003c\/li\u003e\n\u003cli\u003eOuter Jacket Material: Flame Retardant PVC\u003c\/li\u003e\n\u003cli\u003eOuter Jacket Color: Orange\u003c\/li\u003e\n\u003cli\u003eStrength Member: Aramid Yarn\u003c\/li\u003e\n\u003cli\u003eTight Buffer Material: Flame Retardant PVC\u003c\/li\u003e\n\u003cli\u003eTight Buffer Color: Blue \u0026amp; Orange\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eMechanical Characteristics\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eNominal Outer Diameter\u003c\/li\u003e\n\u003cul\u003e\n\u003cli\u003e3.0 mm x 5.95\u003c\/li\u003e\n\u003cli\u003e2.0 mm x 3.95\u003c\/li\u003e\n\u003cli\u003e1.8 mm x 3.65\u003c\/li\u003e\n\u003cli\u003e1.6 mm x 3.25\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003eMinimum Bend Radius (Installation): 5 mm\/10 mm\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eOptical Characteristics\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eCore Size: 62.5 um\u003c\/li\u003e\n\u003cli\u003eWavelength: (850\/1300) nm\u003c\/li\u003e\n\u003cli\u003eMax. Attenuation: (3.5\/ 1.5) dB\/ km\u003c\/li\u003e\n\u003cli\u003eBandwidth (EMB) (High Performance): 220 MHz @850nm\u003c\/li\u003e\n\u003cli\u003eLink Length (10GB\/s): N\/A\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eAdditional Information\u003c\/h4\u003e\n\u003cp\u003eMulti-Mode cable commonly has a diameter in the 50-to-100 micron range (typical multimode fiber core diameters are 50 or 62.5 micrometers). Multimode fiber gives you high bandwidth at high speeds (10 to 100MBS - Gigabit to 275m to 2km) over medium distances. Light waves are dispersed into numerous paths, or modes, as they travel through the cable's core typically 850 or 1300nm. However, in long cable runs (greater than 3000 feet [914.4 meters), multiple paths of light can cause signal distortion at the receiving end, resulting in an unclear and incomplete data transmission so designers now call for single mode fiber in new applications using Gigabit and beyond.\u003c\/p\u003e","brand":"Primus Cable","offers":[{"title":"3.0 mm","offer_id":30010619232301,"sku":"FB28-3795-MD3R","price":0.3,"currency_code":"USD","in_stock":true},{"title":"2.0 mm","offer_id":31454830035005,"sku":"FB28-3805-MD2R","price":0.3,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0252\/1897\/3741\/products\/Duplex-MM.png?v=1567190848"},{"product_id":"simplex-fiber-optic-cable-multimode-50125-10-gig-om4-corning-fiber-indoor-riser","title":"Simplex Riser, Fiber Optic Cable, Multimode, 10 Gig OM4, Corning Fiber, Indoor","description":"\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0252\/1897\/3741\/files\/Made_In_USA.png?2208\" alt=\"Made in USA\" width=\"115px\" height=\"65px\" style=\"background-color: #fff; border-radius: 10px; padding: 5px;\"\u003e \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0252\/1897\/3741\/files\/UL_LISTED_LOGO_US.png?2209\" alt=\"UL Listed\" width=\"75px\" height=\"65px\" style=\"background-color: #fff; border-radius: 10px; padding: 5px;\"\u003e \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0252\/1897\/3741\/files\/Bullets-_RoHS.jpg?2209\" alt=\"RoHS Compliant\" width=\"55px\" height=\"75px\" style=\"background-color: #fff; border-radius: 10px; padding: 5px;\"\u003e \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0252\/1897\/3741\/files\/Bullets_PlusCorning.jpg?2209\" alt=\"Made with Corning Glass\" width=\"170px\" height=\"65px\" style=\"background-color: #fff; border-radius: 10px; padding: 5px;\"\u003e \u003cbr\u003e\u003cmeta charset=\"utf-8\"\u003e\u003c\/p\u003e\n\u003ch3\u003e(We do not offer credits or returns for this item.)\u003cbr\u003eMinimum and Maximum Order Lengths for Non-Freight Shipments:\u003c\/h3\u003e\n\u003ctable width=\"100%\" border=\"1px\" style=\"border: solid medium;\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: solid thin;\" bgcolor=\"#999999\"\u003e \u003c\/td\u003e\n\u003ctd style=\"border: solid thin;\" bgcolor=\"#FFE800\" align=\"center\"\u003e\u003cb\u003e3.0mm\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"border: solid thin;\" bgcolor=\"#FFE800\" align=\"center\"\u003e\u003cb\u003e2.0mm\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"border: solid thin;\" bgcolor=\"#FFE800\" align=\"center\"\u003e\u003cb\u003e1.6mm\u003c\/b\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: solid thin;\" bgcolor=\"#FF6F00\" align=\"center\"\u003e\u003cb\u003eMin.\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"border: solid thin;\" align=\"center\"\u003e1,000ft. (304m)\u003c\/td\u003e\n\u003ctd style=\"border: solid thin;\" align=\"center\"\u003e3,500ft. (1067m)\u003c\/td\u003e\n\u003ctd style=\"border: solid thin;\" align=\"center\"\u003e1,000ft. (304m)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: solid thin;\" bgcolor=\"#FF6F00\" align=\"center\"\u003e\u003cb\u003eMax.\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"border: solid thin;\" align=\"center\"\u003e13,000ft. (3962m)\u003c\/td\u003e\n\u003ctd style=\"border: solid thin;\" align=\"center\"\u003e16,000ft. (4876m)\u003c\/td\u003e\n\u003ctd style=\"border: solid thin;\" align=\"center\"\u003e16,000ft. (4876m)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch5\u003e\n\u003cb\u003eNote:\u003c\/b\u003e To request a quote email us or give us a call.\u003c\/h5\u003e\n\u003ch5\u003eIf you would like to inquire about our custom fiber cable options such as longer lengths, custom cut lengths, terminated ends, or pulleyes please call or email us.\u003c\/h5\u003e\n\u003ch4\u003eDescription\u003c\/h4\u003e\n\u003ch2\u003eSimplex CMR OM4 MultiMode Cable\u003c\/h2\u003e\n\u003cp\u003eRiser Simplex MultiMode OM4 50\/125 Fiber Optic Cable is composed of a tight buffer, aramid yarn, and a PVC outer jacket. All component materials meet the EU RoHS and REACH Directive standards.\u003c\/p\u003e\n\u003cp\u003eThese riser simplex fiber cables are available in 12 TIA standard colors or special order colors. The fiber cable is UL Listed OFNR for use in vertical runs in building riser shafts or from floor to floor. Standard surface print denotes construction, NEC rating, and fiber type, and includes footage markers. Custom print can also be accommodated.\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eCleaning your fiber connector end faces and components regularly is crucial for avoiding a total network failure. Ensure your optical fiber system is working properly and prevent major network issues with \u003c\/span\u003e\u003ca href=\"https:\/\/www.primuscable.com\/collections\/fiber-cleaning-kit\" alt=\"Fiber Cleaning Kits\" target=\"_blank\"\u003e\u003cstrong\u003efiber cleaning kits,\u003c\/strong\u003e\u003c\/a\u003e\u003cspan\u003e \u003c\/span\u003e\u003ca href=\"https:\/\/www.primuscable.com\/collections\/fiber-cleaning-pens\" alt=\"Fiber Cleaning Pens\" target=\"_blank\"\u003e\u003cstrong\u003epens,\u003c\/strong\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/www.primuscable.com\/collections\/fiber-cleaning-fluids\" alt=\"Fiber Cleaning Fluids\" target=\"_blank\"\u003e\u003cstrong\u003e\u003cspan\u003e \u003c\/span\u003efluids,\u003c\/strong\u003e\u003c\/a\u003e\u003cspan\u003e and \u003c\/span\u003e\u003ca href=\"https:\/\/www.primuscable.com\/collections\/fiber-cleaning-wipes\" alt=\"Fiber Cleaning Wipes\" target=\"_blank\"\u003e\u003cstrong\u003ewipes.\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003ch4\u003eFeatures\u003c\/h4\u003e\n\u003ch3\u003e\u003cspan style=\"text-decoration: underline;\"\u003eFeatures\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e3mm, 2mm \u0026amp; 1.6mm OD sizes to meet all patch cord applications.\u003c\/li\u003e\n\u003cli\u003eConsistent 3.5lbs - 5lbs pull force for easy strip-ability.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003ePatch cord production.\u003c\/li\u003e\n\u003cli\u003eData centers.\u003c\/li\u003e\n\u003cli\u003eIndoor point to point connections.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eSpecifications\u003c\/h4\u003e\n\u003ch2\u003eTemperature Range\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eStorage Temperature: -40ºC to +70ºC\u003c\/li\u003e\n\u003cli\u003eOperating Temperature: -20ºC to +70ºC\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCable Characteristics\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eFiber Count: 1\u003c\/li\u003e\n\u003cli\u003eOuter Jacket Material: Flame Retardant PVC\u003c\/li\u003e\n\u003cli\u003eOuter Jacket Color: Aqua\u003c\/li\u003e\n\u003cli\u003eStrength Member: Aramid Yarn\u003c\/li\u003e\n\u003cli\u003eTight Buffer Material: Flame Retardant PVC\u003c\/li\u003e\n\u003cli\u003eTight Buffer Color: White\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eMechanical Characteristics\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eNominal Outer Diameter\u003c\/li\u003e\n\u003cul\u003e\n\u003cli\u003e1.6 mm\u003c\/li\u003e\n\u003cli\u003e2 mm\u003c\/li\u003e\n\u003cli\u003e3 mm\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003eMinimum Bend Radius (Installation): 5 mm\/10 mm\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eOptical Characteristics\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eCore Size: 50 um\u003c\/li\u003e\n\u003cli\u003eWavelength: (850\/1300) nm\u003c\/li\u003e\n\u003cli\u003eMax. Attenuation: (3.5\/1.5) dB\/km\u003c\/li\u003e\n\u003cli\u003eBandwidth (EMB) (High Performance): 4700 MHz @ 850nm\u003c\/li\u003e\n\u003cli\u003eLink Length (10GB\/s): 550 Meters\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eAdditional Information\u003c\/h4\u003e\n\u003cp\u003eMulti-Mode cable commonly has a diameter in the 50-to-100 micron range (typical multimode fiber core diameters are 50 or 62.5 micrometers). Multimode fiber gives you high bandwidth at high speeds (10 to 100MBS - Gigabit to 275m to 2km) over medium distances. Light waves are dispersed into numerous paths, or modes, as they travel through the cable's core typically 850 or 1300nm. However, in long cable runs (greater than 3000 feet [914.4 meters), multiple paths of light can cause signal distortion at the receiving end, resulting in an unclear and incomplete data transmission so designers now call for single mode fiber in new applications using Gigabit and beyond.\u003c\/p\u003e","brand":"Primus Cable","offers":[{"title":"3.0 mm","offer_id":30010831372333,"sku":"FB30-3818-MS3R","price":0.0,"currency_code":"USD","in_stock":true},{"title":"2.0 mm","offer_id":31429353701437,"sku":"FB30-3828-MS2R","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0252\/1897\/3741\/products\/Simplex-10G.png?v=1567190848"},{"product_id":"military-fiber-optic-cable-single-mode-9125-outdoor-tactical-breakout-polyurethane","title":"Military Polyurethane Fiber Optic Cable, Single Mode, Outdoor Tactical Breakout","description":"\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0252\/1897\/3741\/files\/Made_In_USA.png?2208\" alt=\"Made in USA\" width=\"115px\" height=\"65px\" style=\"background-color: #fff; border-radius: 10px; padding: 5px;\"\u003e \u003cmeta charset=\"utf-8\"\u003e\u003c\/p\u003e\n\u003ch3\u003e(We do not offer credits or returns for this item.)\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eIf you would like to inquire about our custom fiber cable options such as terminated ends, pulleyes, and custom cut lengths, please call or email us.\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch4\u003eDescription\u003c\/h4\u003e\n\u003ch2\u003eMilitary Fiber Optic Cable, Single Mode, 9\/125, Outdoor Tactical Breakout, Polyurethane\u003c\/h2\u003e\n\u003cp\u003eThis single mode military tactical breakout cable is ideal for outdoor applications where deployment and retrieval for reuse is required. Having an extremely strong, lightweight and rugged design, the mil tac single mode cable is designed for military tactical field use and commercial applications. The 2.0mm subcables allow for easy direct terminations of fiber connectors on each individually jacketed strand. These tactical breakout fiber cables have been tested for and are currently in use in military data communication applications worldwide.\u003c\/p\u003e\n\u003cp\u003eWith options to be pre-spooled on deployable reels for a ready-to-use product and pre-terminated with single fiber or ruggedized multichannel connectors, these military tactical cables can be customized to your specific application.\u003c\/p\u003e\n\u003cp\u003eCleaning your fiber connector end faces and components regularly is crucial for avoiding a total network failure. Ensure your optical fiber system is working properly and prevent major network issues with \u003ca href=\"https:\/\/www.primuscable.com\/collections\/fiber-cleaning-kit\" alt=\"Fiber Cleaning Kits\" target=\"_blank\"\u003e\u003cstrong\u003e fiber cleaning kits,\u003c\/strong\u003e\u003c\/a\u003e \u003ca href=\"https:\/\/www.primuscable.com\/collections\/fiber-cleaning-pens\" alt=\"Fiber Cleaning Pens\" target=\"_blank\"\u003e\u003cstrong\u003e pens,\u003c\/strong\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/www.primuscable.com\/collections\/fiber-cleaning-fluids\" alt=\"Fiber Cleaning Fluids\" target=\"_blank\"\u003e\u003cstrong\u003e fluids,\u003c\/strong\u003e\u003c\/a\u003e and \u003ca href=\"https:\/\/www.primuscable.com\/collections\/fiber-cleaning-wipes\" alt=\"Fiber Cleaning Wipes\" target=\"_blank\"\u003e\u003cstrong\u003ewipes.\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003ch4\u003eFeatures\u003c\/h4\u003e\n\u003ch3\u003e\u003cspan style=\"text-decoration: underline;\"\u003eFeatures\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eExtremely strong, lightweight, rugged, survivable tight-buffered cables designed for military tactical field use and commercial applications\u003c\/li\u003e\n\u003cli\u003ePolyurethane jacketed for abrasion, cut and chemical resistance\u003c\/li\u003e\n\u003cli\u003eCore-locked jacket for improved mechanical performance\u003c\/li\u003e\n\u003cli\u003eBreakout cable design with individual color-coded subcables protecting each optical fiber\u003c\/li\u003e\n\u003cli\u003eCrush resistant and resilient, with two seperate layers of aramid strength members in the subcables for individual single-fiber connector and termination pin, and overall for termination to multiway connector backshells or other housing\u003c\/li\u003e\n\u003cli\u003eHelically stranded cable core for flexibility, deployment survivability and exceptional mechanical protection for the optical fibers\u003c\/li\u003e\n\u003cli\u003eCables have been tested and are in use in military data communications applications worldwide\u003c\/li\u003e\n\u003cli\u003eCan be used outdoors for temporary deployment directly on the ground, in all terrains, including severe environments\u003c\/li\u003e\n\u003cli\u003eSuitable for industrial, mining and petrochemical environments - chemical resistant\u003c\/li\u003e\n\u003cli\u003eRound cable design for easy installation and survivability\u003c\/li\u003e\n\u003cli\u003eIdeally suited for use with MIL-C-38999 style military connectors - subcables terminate to individual pins and overall aramid strength member terminates to backshell\u003c\/li\u003e\n\u003cli\u003e2.0 mm subcables standard\u003c\/li\u003e\n\u003cli\u003eTactical Polyurethane (C) outer jacket material is standard. Flame- retardant tactical (V) and Low-Smoke Zero-Halogen (G) outer jacket materials are available\u003c\/li\u003e\n\u003cli\u003eUltra-Fox Plus fiber used for the ultimate environmental and mechanical protection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eGround-tactical cable that is ideal for use in harsh environments where deployment and retrieval for reuse is required\u003c\/li\u003e\n\u003cli\u003eIdeal for applications that require termination of the subcables to a connector\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eOptions\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMil-Tac cables prespooled on deployable reels for a ready-to-use product\u003c\/li\u003e\n\u003cli\u003eMil-Tac cables can be pre-terminated with single-fiber or ruggedized multichannel connectors upon request\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eSpecifications\u003c\/h4\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0079\/8874\/0186\/files\/OCC_Mil-Tac_Break_Fiber.pdf?3711\" target=\"_blank\"\u003e \u003cbutton class=\"download-btn\"\u003eSpec Sheet\u003c\/button\u003e \u003c\/a\u003e \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0079\/8874\/0186\/files\/OCC-Ultra-Fox-perf_chart-1.pdf?1946\" target=\"_blank\"\u003e \u003cbutton class=\"download-btn\"\u003eFiber Performance Chart\u003c\/button\u003e \u003c\/a\u003e \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0079\/8874\/0186\/files\/OCC-Mil-Tac_Installation-General_Guidelines_Rev_B-1.pdf?3926\" target=\"_blank\"\u003e \u003cbutton class=\"download-btn\"\u003eGeneral Guidelines\u003c\/button\u003e \u003c\/a\u003e \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0079\/8874\/0186\/files\/OCC-Mil-Tac_Fiber_Optic_Field_Testing_Guidelines_Rev_A-1.pdf?3926\" target=\"_blank\"\u003e \u003cbutton class=\"download-btn\"\u003eTesting Guidelines\u003c\/button\u003e \u003c\/a\u003e \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0079\/8874\/0186\/files\/OCC-Mil-Tac_Storage_Handling_Rev_B-1.pdf?3926\" target=\"_blank\"\u003e \u003cbutton class=\"download-btn\"\u003eStorage Handling\u003c\/button\u003e \u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch3\u003eJacket Characteristics\u003c\/h3\u003e\n\u003cdiv class=\"spec-style-1-0\"\u003eOperating Temperature: -55ºC to +85ºC\u003c\/div\u003e\n\u003cdiv class=\"spec-style-2-0\"\u003eStorage Temperature: -70ºC to +85ºC\u003c\/div\u003e\n\u003cdiv class=\"spec-style-1-0\"\u003eCrush Resistance: 440 N\/cm (EIA\/TIA-455-41A military requirements)\u003c\/div\u003e\n\u003cdiv class=\"spec-style-2-0\"\u003eImpact Resistance: 200 impacts (EIA\/TIA-455-25A military requirements)\u003c\/div\u003e\n\u003cdiv class=\"spec-style-1-0\"\u003eFlex Resistance: 2,000 cycles (EIA\/TIA-455-104A military requirements)\u003c\/div\u003e\n\u003cdiv class=\"spec-clear\"\u003e\u003cbr\u003e\u003c\/div\u003e","brand":"OCC","offers":[{"title":"2 Strand","offer_id":30010701971501,"sku":"B-002CSLS5KM","price":0.0,"currency_code":"USD","in_stock":true},{"title":"6 Strand","offer_id":31424923041853,"sku":"B-006CSLS5KM","price":0.0,"currency_code":"USD","in_stock":true},{"title":"12 Strand","offer_id":31424937820221,"sku":"B-012CSLS5KM","price":0.0,"currency_code":"USD","in_stock":true},{"title":"24 Strand","offer_id":31424946208829,"sku":"B-024CSLS5KM","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0252\/1897\/3741\/products\/Breakout-IO_00aba18f-bca1-4984-ba3f-21cf92ec58be.png?v=1567190849"},{"product_id":"duplex-fiber-optic-cable-zip-cord-multimode-50125-10-gig-om3-corning-fiber-indoor-plenum","title":"Duplex Plenum Fiber Optic Cable, Zip Cord, Multimode 10 Gig OM3, Corning Fiber, Indoor","description":"\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0252\/1897\/3741\/files\/Made_In_USA.png?2208\" alt=\"Made in USA\" width=\"115px\" height=\"65px\" style=\"background-color: #fff; border-radius: 10px; padding: 5px;\"\u003e \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0252\/1897\/3741\/files\/UL_LISTED_LOGO_US.png?2209\" alt=\"UL Listed\" width=\"75px\" height=\"65px\" style=\"background-color: #fff; border-radius: 10px; padding: 5px;\"\u003e \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0252\/1897\/3741\/files\/Bullets-_RoHS.jpg?2209\" alt=\"RoHS Compliant\" width=\"55px\" height=\"75px\" style=\"background-color: #fff; border-radius: 10px; padding: 5px;\"\u003e \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0252\/1897\/3741\/files\/Bullets_PlusCorning.jpg?2209\" alt=\"Made with Corning Glass\" width=\"170px\" height=\"65px\" style=\"background-color: #fff; border-radius: 10px; padding: 5px;\"\u003e \u003cmeta charset=\"utf-8\"\u003e\u003c\/p\u003e\n\u003ch3\u003e(We do not offer credits or returns for this item.)\u003c\/h3\u003e\n\u003ch5\u003e\n\u003cb\u003eNote:\u003c\/b\u003e To request a quote email us or give us a call.\u003c\/h5\u003e\n\u003ch5\u003eIf you would like to inquire about our custom fiber cable options such as longer lengths, custom cut lengths, terminated ends, or pulleys please call or email us.\u003c\/h5\u003e\n\u003ch4\u003eDescription\u003c\/h4\u003e\n\u003ch2\u003eDuplex CMP OM3 MultiMode Fiber Cable\u003c\/h2\u003e\n\u003cp\u003ePlenum CMP Duplex OM3 MultiMode 50\/125 Fiber Cable is composed of a tight buffer, aramid yarn, and a PVC outer jacket. All component materials meet the EU RoHS and REACH Directive standards.\u003c\/p\u003e\n\u003cp\u003eThese plenum duplex fiber cables are available in 12 TIA standard colors or special order colors. The fiber cable is UL Listed OFNP for use in ducts, plenums and air-handling spaces. Standard surface print denotes construction, NEC rating, and fiber type, and includes footage markers. Custom print can also be accommodated.\u003c\/p\u003e\n\u003cp\u003eCleaning your fiber connector end faces and components regularly is crucial for avoiding a total network failure. Ensure your optical fiber system is working properly and prevent major network issues with \u003ca alt=\"Fiber Cleaning Kits\" href=\"https:\/\/www.primuscable.com\/collections\/fiber-cleaning-kit\" target=\"_blank\"\u003e\u003cstrong\u003e fiber cleaning kits,\u003c\/strong\u003e\u003c\/a\u003e \u003ca alt=\"Fiber Cleaning Pens\" href=\"https:\/\/www.primuscable.com\/collections\/fiber-cleaning-pens\" target=\"_blank\"\u003e\u003cstrong\u003e pens,\u003c\/strong\u003e\u003c\/a\u003e\u003ca alt=\"Fiber Cleaning Fluids\" href=\"https:\/\/www.primuscable.com\/collections\/fiber-cleaning-fluids\" target=\"_blank\"\u003e\u003cstrong\u003e fluids,\u003c\/strong\u003e\u003c\/a\u003e and \u003ca alt=\"Fiber Cleaning Wipes\" href=\"https:\/\/www.primuscable.com\/collections\/fiber-cleaning-wipes\" target=\"_blank\"\u003e\u003cstrong\u003ewipes.\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003ch4\u003eFeatures\u003c\/h4\u003e\n\u003ch3\u003e\u003cspan style=\"text-decoration: underline;\"\u003eFeatures\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e3mm, 2mm, 1.8mm \u0026amp; 1.6mm OD sizes to meet all patch cord applications.\u003c\/li\u003e\n\u003cli\u003eConsistent 3.5lbs - 5lbs pull force for easy stripability.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003ePatch cord production.\u003c\/li\u003e\n\u003cli\u003eData centers.\u003c\/li\u003e\n\u003cli\u003eIndoor point to point connections.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eSpecifications\u003c\/h4\u003e\n\u003ch3\u003eTemperature Range\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eStorage Temperature: -40ºC to +70ºC\u003c\/li\u003e\n\u003cli\u003eOperating Temperature: -20ºC to +70ºC\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCable Characteristics\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eFiber Count: 2\u003c\/li\u003e\n\u003cli\u003eOuter Jacket Material: Flame Retardant PVC\u003c\/li\u003e\n\u003cli\u003eOuter Jacket Color: Aqua\u003c\/li\u003e\n\u003cli\u003eStrength Member: Aramid Yarn\u003c\/li\u003e\n\u003cli\u003eTight Buffer Material: Flame Retardant PVC\u003c\/li\u003e\n\u003cli\u003eTight Buffer Color: White \u0026amp; Aqua\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eMechanical Characteristics\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eNominal Outer Diameter\u003c\/li\u003e\n\u003cul\u003e\n\u003cli\u003e3.0 mm x 5.95\u003c\/li\u003e\n\u003cli\u003e2.0 mm x 3.95\u003c\/li\u003e\n\u003cli\u003e1.8 mm x 3.65\u003c\/li\u003e\n\u003cli\u003e1.6 mm x 3.25\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003eMinimum Bend Radius (mm) (Bend Insensitive MM) 7.5\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eOptical Characteristics\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eCore Size: 50 um\u003c\/li\u003e\n\u003cli\u003eWavelength: (850\/1300) nm\u003c\/li\u003e\n\u003cli\u003eMax. Attenuation: (3.5\/1.5) dB\/km\u003c\/li\u003e\n\u003cli\u003eBandwidth (EMB) (High Performance): 2000 MHz @ 850nm\u003c\/li\u003e\n\u003cli\u003eLink Length (10GB\/s): 300 Meters\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eAdditional Information\u003c\/h4\u003e\n\u003cp\u003eMulti-Mode cable commonly has a diameter in the 50-to-100 micron range (typical multimode fiber core diameters are 50 or 62.5 micrometers). Multimode fiber gives you high bandwidth at high speeds (10 to 100MBS - Gigabit to 275m to 2km) over medium distances. Light waves are dispersed into numerous paths, or modes, as they travel through the cable's core typically 850 or 1300nm. However, in long cable runs (greater than 3000 feet [914.4 meters), multiple paths of light can cause signal distortion at the receiving end, resulting in an unclear and incomplete data transmission so designers now call for single mode fiber in new applications using Gigabit and beyond.\u003c\/p\u003e","brand":"Primus Cable","offers":[{"title":"3.0 mm","offer_id":30010619068461,"sku":"FB29-3802-MD3P","price":0.43,"currency_code":"USD","in_stock":true},{"title":"2.0 mm","offer_id":31459957768253,"sku":"FB29-3812-MD2P","price":0.43,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0252\/1897\/3741\/products\/Duplex-10G_8676d37c-ce4a-4bd8-ae4f-9501d6614dd4.png?v=1567190849"},{"product_id":"duplex-fiber-optic-cable-zip-cord-multimode-50125-10-gig-om4-corning-fiber-indoor-plenum","title":"Duplex Plenum Fiber Optic Cable, Zip Cord, Multimode 10 Gig OM4, Corning Fiber, Indoor","description":"\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0252\/1897\/3741\/files\/Made_In_USA.png?2208\" alt=\"Made in USA\" width=\"115px\" height=\"65px\" style=\"background-color: #fff; border-radius: 10px; padding: 5px;\"\u003e \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0252\/1897\/3741\/files\/UL_LISTED_LOGO_US.png?2209\" alt=\"UL Listed\" width=\"75px\" height=\"65px\" style=\"background-color: #fff; border-radius: 10px; padding: 5px;\"\u003e \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0252\/1897\/3741\/files\/Bullets-_RoHS.jpg?2209\" alt=\"RoHS Compliant\" width=\"55px\" height=\"75px\" style=\"background-color: #fff; border-radius: 10px; padding: 5px;\"\u003e \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0252\/1897\/3741\/files\/Bullets_PlusCorning.jpg?2209\" alt=\"Made with Corning Glass\" width=\"170px\" height=\"65px\" style=\"background-color: #fff; border-radius: 10px; padding: 5px;\"\u003e\u003c\/p\u003e\n\u003ch5\u003e\n\u003cb\u003eNote:\u003c\/b\u003e To request a quote email us or give us a call.\u003c\/h5\u003e\n\u003ch5\u003eIf you would like to inquire about our custom fiber cable options such as longer lengths, custom cut lengths, terminated ends, or pulleyes please call or email us.\u003c\/h5\u003e\n\u003ch3\u003e(We do not offer credits or returns for this item.)\u003c\/h3\u003e\n\u003ch4\u003eDescription\u003c\/h4\u003e\n\u003ch2\u003eDuplex CMP OM4 MultiMode Fiber Cable\u003c\/h2\u003e\n\u003cp\u003ePlenum CMP Duplex OM4 MultiMode 50\/125 Fiber Cable is composed of a tight buffer, aramid yarn, and a PVC outer jacket. All component materials meet the EU RoHS and REACH Directive standards.\u003c\/p\u003e\n\u003cp\u003eThese plenum duplex fiber cables are available in 12 TIA standard colors or special order colors. The fiber cable is UL Listed OFNP for use in ducts, plenums and air-handling spaces. Standard surface print denotes construction, NEC rating, and fiber type, and includes footage markers. Custom print can also be accommodated.\u003c\/p\u003e\n\u003cp\u003eCleaning your fiber connector end faces and components regularly is crucial for avoiding a total network failure. Ensure your optical fiber system is working properly and prevent major network issues with \u003ca alt=\"Fiber Cleaning Kits\" href=\"https:\/\/www.primuscable.com\/collections\/fiber-cleaning-kit\" target=\"_blank\"\u003e\u003cstrong\u003e fiber cleaning kits,\u003c\/strong\u003e\u003c\/a\u003e \u003ca alt=\"Fiber Cleaning Pens\" href=\"https:\/\/www.primuscable.com\/collections\/fiber-cleaning-pens\" target=\"_blank\"\u003e\u003cstrong\u003e pens,\u003c\/strong\u003e\u003c\/a\u003e\u003ca alt=\"Fiber Cleaning Fluids\" href=\"https:\/\/www.primuscable.com\/collections\/fiber-cleaning-fluids\" target=\"_blank\"\u003e\u003cstrong\u003e fluids,\u003c\/strong\u003e\u003c\/a\u003e and \u003ca alt=\"Fiber Cleaning Wipes\" href=\"https:\/\/www.primuscable.com\/collections\/fiber-cleaning-wipes\" target=\"_blank\"\u003e\u003cstrong\u003ewipes.\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003ch4\u003eFeatures\u003c\/h4\u003e\n\u003ch3\u003e\u003cspan style=\"text-decoration: underline;\"\u003eFeatures\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e3mm, 2mm, 1.8mm \u0026amp; 1.6mm OD sizes to meet all patch cord applications.\u003c\/li\u003e\n\u003cli\u003eConsistent 3.5lbs - 5lbs pull force for easy stripability.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003ePatch cord production.\u003c\/li\u003e\n\u003cli\u003eData centers.\u003c\/li\u003e\n\u003cli\u003eIndoor point to point connections.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eSpecifications\u003c\/h4\u003e\n\u003ch3\u003eTemperature Range\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eStorage Temperature: -40ºC to +70ºC\u003c\/li\u003e\n\u003cli\u003eOperating Temperature: -20ºC to +70ºC\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCable Characteristics\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eFiber Count: 2\u003c\/li\u003e\n\u003cli\u003eOuter Jacket Material: Flame Retardant PVC\u003c\/li\u003e\n\u003cli\u003eOuter Jacket Color: Aqua\u003c\/li\u003e\n\u003cli\u003eStrength Member: Aramid Yarn\u003c\/li\u003e\n\u003cli\u003eTight Buffer Material: Flame Retardant PVC\u003c\/li\u003e\n\u003cli\u003eTight Buffer Color: White \u0026amp; Aqua\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eMechanical Characteristics\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eNominal Outer Diameter\u003c\/li\u003e\n\u003cul\u003e\n\u003cli\u003e3.0 mm x 5.95\u003c\/li\u003e\n\u003cli\u003e2.0 mm x 3.95\u003c\/li\u003e\n\u003cli\u003e1.8 mm x 3.65\u003c\/li\u003e\n\u003cli\u003e1.6 mm x 3.25\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003eMinimum Bend Radius (mm) (Bend Insensitive MM) 7.5\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eOptical Characteristics\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eCore Size: 50 um\u003c\/li\u003e\n\u003cli\u003eWavelength: (850\/1300) nm\u003c\/li\u003e\n\u003cli\u003eMax. Attenuation: (3.5\/1.5) dB\/km\u003c\/li\u003e\n\u003cli\u003eBandwidth (EMB) (High Performance): 4700 MHz @ 850nm\u003c\/li\u003e\n\u003cli\u003eLink Length (10GB\/s): 550 Meters\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eAdditional Information\u003c\/h4\u003e\n\u003cp\u003eMulti-Mode cable commonly has a diameter in the 50-to-100 micron range (typical multimode fiber core diameters are 50 or 62.5 micrometers). Multimode fiber gives you high bandwidth at high speeds (10 to 100MBS - Gigabit to 275m to 2km) over medium distances. Light waves are dispersed into numerous paths, or modes, as they travel through the cable's core typically 850 or 1300nm. However, in long cable runs (greater than 3000 feet [914.4 meters), multiple paths of light can cause signal distortion at the receiving end, resulting in an unclear and incomplete data transmission so designers now call for single mode fiber in new applications using Gigabit and beyond.\u003c\/p\u003e","brand":"Primus Cable","offers":[{"title":"3.0 mm","offer_id":30010619133997,"sku":"FB29-3803-MD3P","price":0.0,"currency_code":"USD","in_stock":true},{"title":"2.0 mm","offer_id":31459960750141,"sku":"FB29-3813-MD2P","price":0.0,"currency_code":"USD","in_stock":true},{"title":"1.8 mm","offer_id":31459962978365,"sku":"FB29-####-MD18P","price":0.0,"currency_code":"USD","in_stock":true},{"title":"1.6 mm","offer_id":31459963535421,"sku":"FB29-####-MD16P","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0252\/1897\/3741\/products\/Duplex-10G_ff2358db-7571-4b89-8e54-e0441ece0cc8.png?v=1567190849"},{"product_id":"duplex-fiber-optic-cable-zip-cord-multimode-62-5125-om1-corning-fiber-indoor-plenum","title":"Duplex Plenum Fiber Optic Cable, Zip Cord, Multimode OM1, Corning Fiber, Indoor","description":"\u003cp\u003e\u003cimg style=\"background-color: #fff; border-radius: 10px; padding: 5px;\" height=\"65px\" width=\"115px\" alt=\"Made in USA\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0252\/1897\/3741\/files\/Made_In_USA.png?2208\"\u003e \u003cimg style=\"background-color: #fff; border-radius: 10px; padding: 5px;\" height=\"65px\" width=\"75px\" alt=\"UL Listed\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0252\/1897\/3741\/files\/UL_LISTED_LOGO_US.png?2209\"\u003e \u003cimg style=\"background-color: #fff; border-radius: 10px; padding: 5px;\" height=\"75px\" width=\"55px\" alt=\"RoHS Compliant\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0252\/1897\/3741\/files\/Bullets-_RoHS.jpg?2209\"\u003e \u003cimg style=\"background-color: #fff; border-radius: 10px; padding: 5px;\" height=\"65px\" width=\"170px\" alt=\"Made with Corning Glass\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0252\/1897\/3741\/files\/Bullets_PlusCorning.jpg?2209\"\u003e \u003cmeta charset=\"utf-8\"\u003e\u003c\/p\u003e\n\u003ch3\u003e(We do not offer credits or returns for this item.)\u003c\/h3\u003e\n\u003ch5\u003e\n\u003cb\u003eNote:\u003c\/b\u003e To request a quote email us or give us a call.\u003c\/h5\u003e\n\u003ch5\u003eIf you would like to inquire about our custom fiber cable options such as longer lengths, custom cut lengths, terminated ends, or pulleyes please call or email us.\u003c\/h5\u003e\n\u003ch4\u003eDescription\u003c\/h4\u003e\n\u003ch2\u003eDuplex CMP OM1 MultiMode Fiber Cable\u003c\/h2\u003e\n\u003cp\u003ePlenum CMP Duplex OM1 MultiMode 62.5\/125 Fiber Cable is composed of a tight buffer, aramid yarn, and a PVC outer jacket. All component materials meet the EU RoHS and REACH Directive standards.\u003c\/p\u003e\n\u003cp\u003eThese plenum duplex fiber cables are available in 12 TIA standard colors or special order colors. The fiber cable is UL Listed OFNP for use in ducts, plenums and air-handling spaces. Standard surface print denotes construction, NEC rating, and fiber type, and includes footage markers. Custom print can also be accommodated.\u003c\/p\u003e\n\u003cp\u003eCleaning your fiber connector end faces and components regularly is crucial for avoiding a total network failure. Ensure your optical fiber system is working properly and prevent major network issues with \u003ca alt=\"Fiber Cleaning Kits\" href=\"https:\/\/www.primuscable.com\/collections\/fiber-cleaning-kit\" target=\"_blank\"\u003e\u003cstrong\u003e fiber cleaning kits,\u003c\/strong\u003e\u003c\/a\u003e \u003ca alt=\"Fiber Cleaning Pens\" href=\"https:\/\/www.primuscable.com\/collections\/fiber-cleaning-pens\" target=\"_blank\"\u003e\u003cstrong\u003e pens,\u003c\/strong\u003e\u003c\/a\u003e\u003ca alt=\"Fiber Cleaning Fluids\" href=\"https:\/\/www.primuscable.com\/collections\/fiber-cleaning-fluids\" target=\"_blank\"\u003e\u003cstrong\u003e fluids,\u003c\/strong\u003e\u003c\/a\u003e and \u003ca alt=\"Fiber Cleaning Wipes\" href=\"https:\/\/www.primuscable.com\/collections\/fiber-cleaning-wipes\" target=\"_blank\"\u003e\u003cstrong\u003ewipes.\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003ch4\u003eFeatures\u003c\/h4\u003e\n\u003ch3\u003e\u003cspan style=\"text-decoration: underline;\"\u003eFeatures\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e3mm, 2mm, 1.8mm \u0026amp; 1.6mm OD sizes to meet all patch cord applications.\u003c\/li\u003e\n\u003cli\u003eConsistent 3.5lbs - 5lbs pull force for easy stripability.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003ePatch cord production.\u003c\/li\u003e\n\u003cli\u003eData centers.\u003c\/li\u003e\n\u003cli\u003eIndoor point to point connections.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eSpecifications\u003c\/h4\u003e\n\u003ch3\u003eTemperature Range\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eStorage Temperature: -40ºC to +70ºC\u003c\/li\u003e\n\u003cli\u003eOperating Temperature: -20ºC to +70ºC\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCable Characteristics\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eFiber Count: 2\u003c\/li\u003e\n\u003cli\u003eOuter Jacket Material: Flame Retardant PVC\u003c\/li\u003e\n\u003cli\u003eOuter Jacket Color: Orange\u003c\/li\u003e\n\u003cli\u003eStrength Member: Aramid Yarn\u003c\/li\u003e\n\u003cli\u003eTight Buffer Material: Flame Retardant PVC\u003c\/li\u003e\n\u003cli\u003eTight Buffer Color: Blue \u0026amp; Orange\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eMechanical Characteristics\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eNominal Outer Diameter\u003c\/li\u003e\n\u003cul\u003e\n\u003cli\u003e3.0 mm x 5.95\u003c\/li\u003e\n\u003cli\u003e2.0 mm x 3.95\u003c\/li\u003e\n\u003cli\u003e1.8 mm x 3.65\u003c\/li\u003e\n\u003cli\u003e1.6 mm x 3.25\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003eMinimum Bend Radius (mm) (Bend Insensitive MM) 7.5\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eOptical Characteristics\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eCore Size: 62.5 um\u003c\/li\u003e\n\u003cli\u003eWavelength: (850\/1300) nm\u003c\/li\u003e\n\u003cli\u003eMax. Attenuation: (3.5\/1.5) dB\/km\u003c\/li\u003e\n\u003cli\u003eBandwidth (EMB) (High Performance): 220 MHz @ 850nm\u003c\/li\u003e\n\u003cli\u003eLink Length (10GB\/s): N\/A\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eAdditional Information\u003c\/h4\u003e\n\u003cp\u003eMulti-Mode cable commonly has a diameter in the 50-to-100 micron range (typical multimode fiber core diameters are 50 or 62.5 micrometers). Multimode fiber gives you high bandwidth at high speeds (10 to 100MBS - Gigabit to 275m to 2km) over medium distances. Light waves are dispersed into numerous paths, or modes, as they travel through the cable's core typically 850 or 1300nm. However, in long cable runs (greater than 3000 feet [914.4 meters), multiple paths of light can cause signal distortion at the receiving end, resulting in an unclear and incomplete data transmission so designers now call for single mode fiber in new applications using Gigabit and beyond.\u003c\/p\u003e","brand":"Primus Cable","offers":[{"title":"3.0 mm","offer_id":30010619199533,"sku":"FB29-3800-MD3P","price":0.33,"currency_code":"USD","in_stock":true},{"title":"2.0 mm","offer_id":31459951706173,"sku":"FB29-3810-MD2P","price":0.33,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0252\/1897\/3741\/products\/Duplex-MM_1de6cdc3-687e-4ab1-83a9-156992252d97.png?v=1567190849"},{"product_id":"military-fiber-optic-cable-multimode-62-5125-om1-outdoor-tactical-distribution-polyurethane","title":"Military Tight Buffer Distribution  Polyurethane Fiber Optic Cable, Multimode OM1, Outdoor Tactical","description":"\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0252\/1897\/3741\/files\/Made_In_USA.png?2208\" alt=\"Made in USA\" width=\"115px\" height=\"65px\" style=\"background-color: #fff; border-radius: 10px; padding: 5px;\"\u003e \u003cmeta charset=\"utf-8\"\u003e\u003c\/p\u003e\n\u003ch3\u003e(We do not offer credits or returns for this item.)\u003c\/h3\u003e\n\u003cp\u003e\u003cem\u003eTo order this cable, please see the \u003cstrong\u003eProduct Options\u003c\/strong\u003e tab below and choose the strand count and length needed.\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIf you would like to inquire about our custom fiber cable options such as terminated ends, pulleyes, and custom cut lengths, please call or email us.\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch4\u003eDescription\u003c\/h4\u003e\n\u003ch2\u003eMilitary Tight Buffer Fiber Optic Cable, Multimode 62.5\/125 OM1, Outdoor Tactical Distribution, Polyurethane\u003c\/h2\u003e\n\u003cp\u003eThis Multimode OM1 62.5\/125 Military Tactical Distribution Cable is ideal for outdoor applications where deployment and retrieval for reuse is required. Having an extremely strong, lightweight and rugged design, the mil tac multimode OM1 cable is designed for military tactical field use and commercial applications. These tactical distribution fiber cables have been tested for and are currently in use in military data communication applications worldwide.\u003c\/p\u003e\n\u003cp\u003eWith options to be prespooled on deployable reels for a ready-to-use product and pre-terminated with single fiber or ruggedized multichannel connectors, these military tactical cables can be customized to your specific application.\u003c\/p\u003e\n\u003cp\u003eCleaning your fiber connector end faces and components regularly is crucial for avoiding a total network failure. Ensure your optical fiber system is working properly and prevent major network issues with \u003ca href=\"https:\/\/www.primuscable.com\/collections\/fiber-cleaning-kit\" alt=\"Fiber Cleaning Kits\" target=\"_blank\"\u003e\u003cstrong\u003e fiber cleaning kits,\u003c\/strong\u003e\u003c\/a\u003e \u003ca href=\"https:\/\/www.primuscable.com\/collections\/fiber-cleaning-pens\" alt=\"Fiber Cleaning Pens\" target=\"_blank\"\u003e\u003cstrong\u003e pens,\u003c\/strong\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/www.primuscable.com\/collections\/fiber-cleaning-fluids\" alt=\"Fiber Cleaning Fluids\" target=\"_blank\"\u003e\u003cstrong\u003e fluids,\u003c\/strong\u003e\u003c\/a\u003e and \u003ca href=\"https:\/\/www.primuscable.com\/collections\/fiber-cleaning-wipes\" alt=\"Fiber Cleaning Wipes\" target=\"_blank\"\u003e\u003cstrong\u003ewipes.\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003ch4\u003eFeatures\u003c\/h4\u003e\n\u003ch3\u003e\u003cspan style=\"text-decoration: underline;\"\u003eFeatures\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eExtremely strong, lightweight, rugged, survivable tight-buffered cables designed for military tactical field use and commercial applications\u003c\/li\u003e\n\u003cli\u003eCompact, round cable design for ease of transportation and deployment\u003c\/li\u003e\n\u003cli\u003eCore-locked jacket for improved mechanical performance\u003c\/li\u003e\n\u003cli\u003eDesigned for use in adverse environments where reduced size and weight are important\u003c\/li\u003e\n\u003cli\u003eHelically stranded cable core for flexibility, deployment survivability and exceptional mechanical protection for the optical fibers\u003c\/li\u003e\n\u003cli\u003eCables have been tested and are in use in military data communications applications worldwide\u003c\/li\u003e\n\u003cli\u003eCan be used outdoors for temporary deployment directly on the ground in all terrains, including severe environments\u003c\/li\u003e\n\u003cli\u003eSuitable for industrial, mining and petrochemical environments - chemical resistant\u003c\/li\u003e\n\u003cli\u003eCrush-resistant and resilient with a thick layer of aramid strength members\u003c\/li\u003e\n\u003cli\u003ePolyurethane jacketed for abrasion, cut and chemical resistance\u003c\/li\u003e\n\u003cli\u003eMost commonly used with ruggedized multiway military tactical field connectors, for maximum connector retention (400lbs.)\u003c\/li\u003e\n\u003cli\u003eTactical Polyurethane (C) outer jacket material is standard; Flame-Retardant Tactical (V) and Low-Smoke Zero-Halogen (G) outer jacket materials are available\u003c\/li\u003e\n\u003cli\u003eUltra-Fox Plus Fiber (500um) used for environmental and mechanical protection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eGround-tactical cable that is ideal for use in harsh environments where deployment and retrieval for reuse is required\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eProvided Options\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMil-Tac cables pre-spooled on deployable reels for a ready-to-use product\u003c\/li\u003e\n\u003cli\u003eMil-Tac cables can be pre-terminated with single-fiber or ruggedized multichannel connectors upon request\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eSpecifications\u003c\/h4\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0079\/8874\/0186\/files\/OCC_SM_Mil-Tac_Dist_Fiber.pdf?3697\" target=\"_blank\"\u003e \u003cbutton class=\"download-btn\"\u003eSpec Sheet\u003c\/button\u003e \u003c\/a\u003e \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0079\/8874\/0186\/files\/OCC-Ultra-Fox-perf_chart-1.pdf?1946\" target=\"_blank\"\u003e \u003cbutton class=\"download-btn\"\u003eFiber Performance Chart\u003c\/button\u003e \u003c\/a\u003e \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0079\/8874\/0186\/files\/OCC-Mil-Tac_Installation-General_Guidelines_Rev_B-1.pdf?3926\" target=\"_blank\"\u003e \u003cbutton class=\"download-btn\"\u003eGeneral Guidelines\u003c\/button\u003e \u003c\/a\u003e \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0079\/8874\/0186\/files\/OCC-Mil-Tac_Fiber_Optic_Field_Testing_Guidelines_Rev_A-1.pdf?3926\" target=\"_blank\"\u003e \u003cbutton class=\"download-btn\"\u003eTesting Guidelines\u003c\/button\u003e \u003c\/a\u003e \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0079\/8874\/0186\/files\/OCC-Mil-Tac_Storage_Handling_Rev_B-1.pdf?3926\" target=\"_blank\"\u003e \u003cbutton class=\"download-btn\"\u003eStorage Handling\u003c\/button\u003e \u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003eJacket Characteristics\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eOperating Temperature: -55ºC to +85ºC\u003c\/li\u003e\n\u003cli\u003eStorage Temperature: -70™C to +85™C\u003c\/li\u003e\n\u003cli\u003eCrush Resistance: 440 N\/cm (EIA\/TIA-455-41A military requirements)\u003c\/li\u003e\n\u003cli\u003eImpact Resistance: 200 impacts (EIA\/TIA-455-25A military requirements)\u003c\/li\u003e\n\u003cli\u003eFlex Resistance: 2,000 cycles (EIA\/TIA-455-104A military requirements)\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"OCC","offers":[{"title":"2 Strand","offer_id":30010701938733,"sku":"D-002CWST5KM","price":0.87,"currency_code":"USD","in_stock":true},{"title":"6 Strand","offer_id":31411381207101,"sku":"D-006CWST5KM","price":2.05,"currency_code":"USD","in_stock":true},{"title":"12 Strand","offer_id":31411384582205,"sku":"D-012CWST5KM","price":3.83,"currency_code":"USD","in_stock":true},{"title":"24 Strand","offer_id":31411386253373,"sku":"D-024CWST5KM","price":8.86,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0252\/1897\/3741\/products\/Distribution-IO_645c3bf1-1a9f-4573-888a-12730e77e42c.png?v=1567190849"},{"product_id":"high-density-fiber-optic-cable-multimode-50125-10-gig-om3-indooroutdoor-riser","title":"High-Density Riser Fiber Optic Cable, Multimode 10 Gig OM3, Indoor\/Outdoor","description":"\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0252\/1897\/3741\/files\/Made_In_USA.png?2208\" alt=\"Made in USA\" width=\"115px\" height=\"65px\" class=\"bulleticons\"\u003e \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0252\/1897\/3741\/files\/UL_LISTED_LOGO_US.png?2209\" alt=\"UL Listed\" width=\"76px\" height=\"65px\" class=\"bulleticons\"\u003e \u003cmeta charset=\"utf-8\"\u003e\u003c\/p\u003e\n\u003ch3\u003e(We do not offer credits or returns for this item.)\u003c\/h3\u003e\n\u003cp\u003e\u003cem\u003eTo order this cable, please see the \u003cstrong\u003eProduct Options\u003c\/strong\u003e tab below and choose the strand count and length needed.\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIf you would like to inquire about our custom fiber cable options such as terminated ends, pulleyes, and custom cut lengths, please call or email us.\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch4\u003eDescription\u003c\/h4\u003e\n\u003ch3\u003eHigh-density Fiber Cable\u003c\/h3\u003e\n\u003cp\u003eThe new high density fiber cable is extraordinary. There is nothing else like it. Like loose-tube gel-filled cables, it utilizes 245 um fibers as opposed to 900 um tight buffered fibers and it does require breakout kits, but instead uses special \u003ca href=\"\/store\/p\/8291-Fan-out-Kit-12-Fiber-24-Leads-900um-Tubing-High-density-Cable-Only.aspx\" rel=\"noopener noreferrer\" target=\"_blank\"\u003e12 fiber fan-out kits\u003c\/a\u003e and a \u003ca href=\"\/store\/p\/8292-Fiber-Slitter-and-Stripper-2-2mm-Outer-Jacket-245um-Fiber.aspx\" rel=\"noopener noreferrer\" target=\"_blank\"\u003efiber stripper\/slitter\u003c\/a\u003e to terminate. The high density fiber cable's water resistance characteristics surpass loose tube cables.\u003c\/p\u003e\n\u003cp\u003eWith the high-density fiber cables, the 245 um fibers are encapsulated within a tight buffer. Easily prepared for termination, high-density cables feature the smallest outer diameter within the industry and still retain rugged characteristics: lightweight, flexible, and easy to work with and at a crush rating of 1800 N\/cm and a flex rating of 2,000 cycles!\u003c\/p\u003e\n\u003cp\u003eCleaning your fiber connector end faces and components regularly is crucial for avoiding a total network failure. Ensure your optical fiber system is working properly and prevent major network issues with \u003ca href=\"https:\/\/www.primuscable.com\/collections\/fiber-cleaning-kit\" alt=\"Fiber Cleaning Kits\" target=\"_blank\"\u003e\u003cstrong\u003e fiber cleaning kits,\u003c\/strong\u003e\u003c\/a\u003e \u003ca href=\"https:\/\/www.primuscable.com\/collections\/fiber-cleaning-pens\" alt=\"Fiber Cleaning Pens\" target=\"_blank\"\u003e\u003cstrong\u003e pens,\u003c\/strong\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/www.primuscable.com\/collections\/fiber-cleaning-fluids\" alt=\"Fiber Cleaning Fluids\" target=\"_blank\"\u003e\u003cstrong\u003e fluids,\u003c\/strong\u003e\u003c\/a\u003e and \u003ca href=\"https:\/\/www.primuscable.com\/collections\/fiber-cleaning-wipes\" alt=\"Fiber Cleaning Wipes\" target=\"_blank\"\u003e\u003cstrong\u003ewipes.\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003ch4\u003eFeatures\u003c\/h4\u003e\n\u003ch3\u003e\u003cspan style=\"text-decoration: underline;\"\u003eFeatures\u003c\/span\u003e\u003c\/h3\u003e\n\u003ch3\u003eApplications:\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDesigned for installation in an underground duct for data transmission between nodes or hubs\u003c\/li\u003e\n\u003cli\u003eCable can also be routed vertically inside buildings\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFeatures:\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eRugged tight-buffered fiber unit construction\u003c\/li\u003e\n\u003cli\u003eCable materials are indoor\/outdoor: UV, fungus, and water resistant\u003c\/li\u003e\n\u003cli\u003eThe high-density breakout cables offer a \u0026gt;20% reduction in diameter and a \u0026gt;20% reduction in weight relative to conventional loose-tube cables, allowing for greater fiber density and cable packing within a duct\u003c\/li\u003e\n\u003cli\u003eUL listed in accordance with NEC 770.179(b) for use in vertical runs in building risers or from floor to floor\u003c\/li\u003e\n\u003cli\u003eCore-Locked™ outer jacket design for installation survivability\u003c\/li\u003e\n\u003cli\u003eHelically stranded core for greater flexibility and mechanical protection of the optical fibers\u003c\/li\u003e\n\u003cli\u003eCable offers a cost savings by eliminating the need to splice outdoor cable at building entrance\u003c\/li\u003e\n\u003cli\u003eCable can be terminated with 900™m fanout kit for LC connectorization\u003c\/li\u003e\n\u003cli\u003eConstruction options available for direct termination of tight-buffered fiber units to MPO\/MTP connectors\u003c\/li\u003e\n\u003cli\u003eSuitable for direct pulling with wire mesh grips\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eSpecifications\u003c\/h4\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0079\/8874\/0186\/files\/OCC-Ultra-Fox-perf_chart-1.pdf?1946\" target=\"_blank\"\u003e \u003cbutton class=\"download-btn\"\u003eFiber Performance Chart\u003c\/button\u003e \u003c\/a\u003e\u003c\/p\u003e\n\u003ch3\u003eJacket Characteristics\u003c\/h3\u003e\n\u003ctable class=\"table table-bordered\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd width=\"25%\"\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-40ºC to +85ºC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStorage Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-55ºC to +85ºC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInstallation Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-20ºC to +60ºC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFlame Retardancy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUL Listed Type OFNR (UL 1666)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCrush Resistance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1,800 N\/cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFlex Resistance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2,000 cycles\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003ctable class=\"OCCSpecTable\" cellspacing=\"0\" align=\"center\"\u003e\n\u003ctbody\u003e\n\u003ctr class=\"tablePadding tablePaddingHeader\" align=\"center\"\u003e\n\u003ctd rowspan=\"2\"\u003eFiber Count\u003c\/td\u003e\n\u003ctd rowspan=\"2\"\u003eDiameter\u003cbr\u003emm (in)\u003c\/td\u003e\n\u003ctd rowspan=\"2\"\u003eWeight\u003cbr\u003ekg\/km (lbs\/1,000ft)\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eTensile Load\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eMinimum Bend Radius\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"tablePadding tablePaddingHeader\" align=\"center\"\u003e\n\u003ctd\u003eInstallation N (lbs)\u003c\/td\u003e\n\u003ctd\u003eOperational N (lbs)\u003c\/td\u003e\n\u003ctd\u003eInstallation cm (in)\u003c\/td\u003e\n\u003ctd\u003eOperational cm (in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"tablePadding\" align=\"center\"\u003e\n\u003ctd\u003e24\u003c\/td\u003e\n\u003ctd\u003e7.6 (0.30)\u003c\/td\u003e\n\u003ctd\u003e75 (50)\u003c\/td\u003e\n\u003ctd\u003e2,700 (600)\u003c\/td\u003e\n\u003ctd\u003e600 (135)\u003c\/td\u003e\n\u003ctd\u003e11.4 (4.5)\u003c\/td\u003e\n\u003ctd\u003e7.6 (3.0)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"tablePadding\" align=\"center\" bgcolor=\"#cccccc\"\u003e\n\u003ctd\u003e48\u003c\/td\u003e\n\u003ctd\u003e7.6 (0.30)\u003c\/td\u003e\n\u003ctd\u003e75 (50)\u003c\/td\u003e\n\u003ctd\u003e2,700 (600)\u003c\/td\u003e\n\u003ctd\u003e600 (135)\u003c\/td\u003e\n\u003ctd\u003e11.4 (4.5)\u003c\/td\u003e\n\u003ctd\u003e7.6 (3.0)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"tablePadding\" align=\"center\"\u003e\n\u003ctd\u003e72\u003c\/td\u003e\n\u003ctd\u003e9.0 (0.35)\u003c\/td\u003e\n\u003ctd\u003e97 (65)\u003c\/td\u003e\n\u003ctd\u003e2,700 (600)\u003c\/td\u003e\n\u003ctd\u003e600 (135)\u003c\/td\u003e\n\u003ctd\u003e13.5 (5.3)\u003c\/td\u003e\n\u003ctd\u003e9.0 (3.5)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"tablePadding\" align=\"center\" bgcolor=\"#cccccc\"\u003e\n\u003ctd\u003e96\u003c\/td\u003e\n\u003ctd\u003e10.3 (0.40)\u003c\/td\u003e\n\u003ctd\u003e116 (78)\u003c\/td\u003e\n\u003ctd\u003e2,700 (600)\u003c\/td\u003e\n\u003ctd\u003e600 (135)\u003c\/td\u003e\n\u003ctd\u003e15.5 (6.0)\u003c\/td\u003e\n\u003ctd\u003e10.3 (4.0)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"tablePadding\" align=\"center\"\u003e\n\u003ctd\u003e120\u003c\/td\u003e\n\u003ctd\u003e11.4 (0.45)\u003c\/td\u003e\n\u003ctd\u003e141 (95)\u003c\/td\u003e\n\u003ctd\u003e3,000 (670)\u003c\/td\u003e\n\u003ctd\u003e1,000 (220)\u003c\/td\u003e\n\u003ctd\u003e17.1 (6.8)\u003c\/td\u003e\n\u003ctd\u003e11.4 (4.5)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"tablePadding\" align=\"center\" bgcolor=\"#cccccc\"\u003e\n\u003ctd\u003e144\u003c\/td\u003e\n\u003ctd\u003e11.7 (0.46)\u003c\/td\u003e\n\u003ctd\u003e152 (102)\u003c\/td\u003e\n\u003ctd\u003e3,000 (670)\u003c\/td\u003e\n\u003ctd\u003e1,000 (220)\u003c\/td\u003e\n\u003ctd\u003e17.6 (6.9)\u003c\/td\u003e\n\u003ctd\u003e11.7 (4.6)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"tablePadding\" align=\"center\"\u003e\n\u003ctd\u003e168\u003c\/td\u003e\n\u003ctd\u003e14.1 (0.56)\u003c\/td\u003e\n\u003ctd\u003e208 (140)\u003c\/td\u003e\n\u003ctd\u003e4,800 (1,080)\u003c\/td\u003e\n\u003ctd\u003e1,600 (360)\u003c\/td\u003e\n\u003ctd\u003e17.6 (6.9)\u003c\/td\u003e\n\u003ctd\u003e11.7 (4.6)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"tablePadding\" align=\"center\" bgcolor=\"#cccccc\"\u003e\n\u003ctd\u003e192\u003c\/td\u003e\n\u003ctd\u003e12.9 (0.51)\u003c\/td\u003e\n\u003ctd\u003e179 (120)\u003c\/td\u003e\n\u003ctd\u003e4,800 (1,080)\u003c\/td\u003e\n\u003ctd\u003e1,600 (360)\u003c\/td\u003e\n\u003ctd\u003e19.4 (7.7)\u003c\/td\u003e\n\u003ctd\u003e12.9 (5.1)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"tablePadding\" align=\"center\"\u003e\n\u003ctd\u003e216\u003c\/td\u003e\n\u003ctd\u003e12.9 (0.51)\u003c\/td\u003e\n\u003ctd\u003e179 (120)\u003c\/td\u003e\n\u003ctd\u003e4,800 (1,080)\u003c\/td\u003e\n\u003ctd\u003e1,600 (360)\u003c\/td\u003e\n\u003ctd\u003e19.4 (7.7)\u003c\/td\u003e\n\u003ctd\u003e12.9 (5.1)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"tablePadding\" align=\"center\" bgcolor=\"#cccccc\"\u003e\n\u003ctd\u003e288\u003c\/td\u003e\n\u003ctd\u003e15.0 (0.60)\u003c\/td\u003e\n\u003ctd\u003e226 (152)\u003c\/td\u003e\n\u003ctd\u003e5,400 (1,210)\u003c\/td\u003e\n\u003ctd\u003e1,800 (400)\u003c\/td\u003e\n\u003ctd\u003e22.58 (9.0)\u003c\/td\u003e\n\u003ctd\u003e15.0 (6.0)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp class=\"impNote\"\u003eInstallation loads in excess of 2,700 N (600 lbs) are not recommended. Contact us for ordering details.\u003c\/p\u003e\n\u003ch4\u003eMultimode Fiber Information\u003c\/h4\u003e\n\u003cp\u003eMulti-Mode cable commonly has a diameter in the 50-to-100 micron range (typical multimode fiber core diameters are 50 or 62.5 micrometers). Multimode fiber gives you high bandwidth at high speeds (10 to 100MBS - Gigabit to 275m to 2km) over medium distances. Light waves are dispersed into numerous paths, or modes, as they travel through the cable's core typically 850 or 1300nm. However, in long cable runs (greater than 3000 feet [914.4 meters), multiple paths of light can cause signal distortion at the receiving end, resulting in an unclear and incomplete data transmission so designers now call for single mode fiber in new applications using Gigabit and beyond.\u003c\/p\u003e","brand":"OCC","offers":[{"title":"24 Strand","offer_id":31134791499837,"sku":"HC024JABTCKR","price":0.0,"currency_code":"USD","in_stock":true},{"title":"48 Strand","offer_id":31134791532605,"sku":"HC048JABTCKR","price":0.0,"currency_code":"USD","in_stock":true},{"title":"72 Strand","offer_id":31134791565373,"sku":"HC072JABTCKR","price":0.0,"currency_code":"USD","in_stock":true},{"title":"96 Strand","offer_id":31134791598141,"sku":"HC096JABTCKR","price":0.0,"currency_code":"USD","in_stock":true},{"title":"120 Strand","offer_id":31134791630909,"sku":"HC120JABTCKR","price":0.0,"currency_code":"USD","in_stock":true},{"title":"144 Strand","offer_id":31134791663677,"sku":"HC144JABTCKR","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0252\/1897\/3741\/products\/HighDensity-Black.png?v=1567190849"},{"product_id":"military-fiber-optic-cable-single-mode-9125-outdoor-tactical-distribution-polyurethane","title":"Military Tight Buffer Distribution Polyurethane Fiber Optic Cable, Single Mode, Outdoor Tactical","description":"\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0252\/1897\/3741\/files\/Made_In_USA.png?2208\" alt=\"Made in USA\" width=\"115px\" height=\"65px\" style=\"background-color: #fff; border-radius: 10px; padding: 5px;\"\u003e \u003cmeta charset=\"utf-8\"\u003e\u003c\/p\u003e\n\u003ch3\u003e(We do not offer credits or returns for this item.)\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eIf you would like to inquire about our custom fiber cable options such as terminated ends, pulleyes, and custom cut lengths, please call or email us.\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch4\u003eDescription\u003c\/h4\u003e\n\u003ch2\u003eMilitary Fiber Optic Cable, Single Mode, 9\/125 Outdoor Tactical Distribution, Polyurethane\u003c\/h2\u003e\n\u003cp\u003eThis single mode military tactical distribution cable is ideal for outdoor applications where deployment and retrieval for reuse is required. Having an extremely strong, lightweight and rugged design, the mil tac single mode cable is designed for military tactical field use and commercial applications. These tactical distribution fiber cables have been tested for and are currently in use in military data communication applications worldwide.\u003c\/p\u003e\n\u003cp\u003eWith options to be pre-spooled on deployable reels for a ready-to-use product and pre-terminated with single fiber or ruggedized multichannel connectors, these military tactical cables can be customized to your specific application.\u003c\/p\u003e\n\u003cp\u003eCleaning your fiber connector end faces and components regularly is crucial for avoiding a total network failure. Ensure your optical fiber system is working properly and prevent major network issues with \u003ca href=\"https:\/\/www.primuscable.com\/collections\/fiber-cleaning-kit\" alt=\"Fiber Cleaning Kits\" target=\"_blank\"\u003e\u003cstrong\u003e fiber cleaning kits,\u003c\/strong\u003e\u003c\/a\u003e \u003ca href=\"https:\/\/www.primuscable.com\/collections\/fiber-cleaning-pens\" alt=\"Fiber Cleaning Pens\" target=\"_blank\"\u003e\u003cstrong\u003e pens,\u003c\/strong\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/www.primuscable.com\/collections\/fiber-cleaning-fluids\" alt=\"Fiber Cleaning Fluids\" target=\"_blank\"\u003e\u003cstrong\u003e fluids,\u003c\/strong\u003e\u003c\/a\u003e and \u003ca href=\"https:\/\/www.primuscable.com\/collections\/fiber-cleaning-wipes\" alt=\"Fiber Cleaning Wipes\" target=\"_blank\"\u003e\u003cstrong\u003ewipes.\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003ch4\u003eFeatures\u003c\/h4\u003e\n\u003ch3\u003e\u003cspan style=\"text-decoration: underline;\"\u003eFeatures\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eExtremely strong, lightweight, rugged, survivable tight-buffered cables designed for military tactical field use and commercial applications\u003c\/li\u003e\n\u003cli\u003eCompact, round cable design for ease of transportation and deployment\u003c\/li\u003e\n\u003cli\u003eCore-locked jacket for improved mechanical performance\u003c\/li\u003e\n\u003cli\u003eDesigned for use in adverse environments where reduced size and weight are important\u003c\/li\u003e\n\u003cli\u003eHelically stranded cable core for flexibility, deployment survivability and exceptional mechanical protection for the optical fibers\u003c\/li\u003e\n\u003cli\u003eCables have been tested and are in use in military data communications applications worldwide\u003c\/li\u003e\n\u003cli\u003eCan be used outdoors for temporary deployment directly on the ground in all terrains, including severe environments\u003c\/li\u003e\n\u003cli\u003eSuitable for industrial, mining and petrochemical environments - chemical resistant\u003c\/li\u003e\n\u003cli\u003eCrush-resistant and resilient with a thick layer of aramid strength members\u003c\/li\u003e\n\u003cli\u003ePolyurethane jacketed for abrasion, cut and chemical resistance\u003c\/li\u003e\n\u003cli\u003eMost commonly used with ruggedized multiway military tactical field connectors, for maximum connector retention (400lbs.)\u003c\/li\u003e\n\u003cli\u003eTactical Polyurethane (C) outer jacket material is standard; Flame-Retardant Tactical (V) and Low-Smoke Zero-Halogen (G) outer jacket materials are available\u003c\/li\u003e\n\u003cli\u003eUltra-Fox Plus Fiber (500um) used for environmental and mechanical protection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eGround-tactical cable that is ideal for use in harsh environments where deployment and retrieval for reuse is required\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eProvided Options\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMil-Tac cables pre-spooled on deployable reels for a ready-to-use product\u003c\/li\u003e\n\u003cli\u003eMil-Tac cables can be pre-terminated with single-fiber or ruggedized multichannel connectors upon request\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eSpecifications\u003c\/h4\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0079\/8874\/0186\/files\/OCC_SM_Mil-Tac_Dist_Fiber.pdf?3697\" target=\"_blank\"\u003e \u003cbutton class=\"download-btn\"\u003eSpec Sheet\u003c\/button\u003e \u003c\/a\u003e \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0079\/8874\/0186\/files\/OCC-Ultra-Fox-perf_chart-1.pdf?1946\" target=\"_blank\"\u003e \u003cbutton class=\"download-btn\"\u003eFiber Performance Chart\u003c\/button\u003e \u003c\/a\u003e \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0079\/8874\/0186\/files\/OCC-Mil-Tac_Installation-General_Guidelines_Rev_B-1.pdf?3926\" target=\"_blank\"\u003e \u003cbutton class=\"download-btn\"\u003eGeneral Guidelines\u003c\/button\u003e \u003c\/a\u003e \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0079\/8874\/0186\/files\/OCC-Mil-Tac_Fiber_Optic_Field_Testing_Guidelines_Rev_A-1.pdf?3926\" target=\"_blank\"\u003e \u003cbutton class=\"download-btn\"\u003eTesting Guidelines\u003c\/button\u003e \u003c\/a\u003e \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0079\/8874\/0186\/files\/OCC-Mil-Tac_Storage_Handling_Rev_B-1.pdf?3926\" target=\"_blank\"\u003e \u003cbutton class=\"download-btn\"\u003eStorage Handling\u003c\/button\u003e \u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch3\u003eJacket Characteristics\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eOperating Temperature: -55ºC to +85ºC\u003c\/li\u003e\n\u003cli\u003eStorage Temperature: -70ºC to +85ºC\u003c\/li\u003e\n\u003cli\u003eCrush Resistance: 440 N\/cm (EIA\/TIA-455-41A military requirements)\u003c\/li\u003e\n\u003cli\u003eImpact Resistance: 200 impacts (EIA\/TIA-455-25A military requirements)\u003c\/li\u003e\n\u003cli\u003eFlex Resistance: 2,000 cycles (EIA\/TIA-455-104A military requirements)\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"OCC","offers":[{"title":"2 Strand","offer_id":30010702004269,"sku":"D-002CSLS5KM","price":0.63,"currency_code":"USD","in_stock":true},{"title":"6 Strand","offer_id":31411024920637,"sku":"D-006CSLS5KM","price":1.35,"currency_code":"USD","in_stock":true},{"title":"12 Strand","offer_id":31411296895037,"sku":"D-012CSLS5KM","price":2.42,"currency_code":"USD","in_stock":true},{"title":"24 Strand","offer_id":31411314032701,"sku":"D-024CSLS5KM","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0252\/1897\/3741\/products\/Distribution-IO_9f6d74dd-1604-462e-8a30-cc507a436f54.png?v=1567190849"},{"product_id":"high-density-fiber-optic-cable-multimode-62-5125-om1-indooroutdoor-riser","title":"High-Density Riser Fiber Optic Cable, Multimode OM1, Indoor\/Outdoor","description":"\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0252\/1897\/3741\/files\/Made_In_USA.png?2208\" alt=\"Made in USA\" width=\"115px\" height=\"65px\" class=\"bulleticons\"\u003e \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0252\/1897\/3741\/files\/UL_LISTED_LOGO_US.png?2209\" alt=\"UL Listed\" width=\"76px\" height=\"65px\" class=\"bulleticons\"\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003eTo order this cable, please see the \u003cstrong\u003eProduct Options\u003c\/strong\u003e tab below and choose the strand count and length needed.\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIf you would like to inquire about our custom fiber cable options such as terminated ends, pulleyes, and custom cut lengths, please call us.\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3\u003eWe do not offer credits or returns for this item\u003c\/h3\u003e\n\u003ch4\u003eDescription\u003c\/h4\u003e\n\u003ch2\u003eHigh-Density Fiber Optic Cable, Multimode, 62.5\/125 OM1, Indoor\/Outdoor, Riser\u003c\/h2\u003e\n\u003cp\u003eThe new high density fiber cable is extraordinary. There is nothing else like it. Like loose-tube gel-filled cables, it utilizes 245 um fibers as opposed to 900 um tight buffered fibers and it does require breakout kits, but instead uses special \u003ca href=\"\/store\/p\/8291-Fan-out-Kit-12-Fiber-24-Leads-900um-Tubing-High-density-Cable-Only.aspx\" target=\"_blank\"\u003e12 fiber fan-out kits\u003c\/a\u003e and a \u003ca href=\"\/store\/p\/8292-Fiber-Slitter-and-Stripper-2-2mm-Outer-Jacket-245um-Fiber.aspx\" target=\"_blank\"\u003efiber stripper\/slitter\u003c\/a\u003e to terminate. The high density fiber cable's water resistance characteristics surpass loose tube cables.\u003c\/p\u003e\n\u003cp\u003eWith the high-density fiber cables, the 245 um fibers are encapsulated within a tight buffer. Easily prepared for termination, high-density cables feature the smallest outer diameter within the industry and still retain rugged characteristics: lightweight, flexible, and easy to work with and at a crush rating of 1800 N\/cm and a flex rating of 2,000 cycles!\u003c\/p\u003e\n\u003cp\u003eCleaning your fiber connector end faces and components regularly is crucial for avoiding a total network failure. Ensure your optical fiber system is working properly and prevent major network issues with \u003ca href=\"https:\/\/www.primuscable.com\/collections\/fiber-cleaning-kit\" alt=\"Fiber Cleaning Kits\" target=\"_blank\"\u003e\u003cstrong\u003e fiber cleaning kits,\u003c\/strong\u003e\u003c\/a\u003e \u003ca href=\"https:\/\/www.primuscable.com\/collections\/fiber-cleaning-pens\" alt=\"Fiber Cleaning Pens\" target=\"_blank\"\u003e\u003cstrong\u003e pens,\u003c\/strong\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/www.primuscable.com\/collections\/fiber-cleaning-fluids\" alt=\"Fiber Cleaning Fluids\" target=\"_blank\"\u003e\u003cstrong\u003e fluids,\u003c\/strong\u003e\u003c\/a\u003e and \u003ca href=\"https:\/\/www.primuscable.com\/collections\/fiber-cleaning-wipes\" alt=\"Fiber Cleaning Wipes\" target=\"_blank\"\u003e\u003cstrong\u003ewipes.\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003ch4\u003eFeatures\u003c\/h4\u003e\n\u003ch3\u003e\u003cspan style=\"text-decoration: underline;\"\u003eFeatures\u003c\/span\u003e\u003c\/h3\u003e\n\u003ch3\u003eApplications:\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDesigned for installation in an underground duct for data transmission between nodes or hubs\u003c\/li\u003e\n\u003cli\u003eCable can also be routed vertically inside buildings\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFeatures:\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eRugged tight-buffered fiber unit construction\u003c\/li\u003e\n\u003cli\u003eCable materials are indoor\/outdoor: UV, fungus, and water resistant\u003c\/li\u003e\n\u003cli\u003eThe high-density breakout cables offer a \u0026gt;20% reduction in diameter and a \u0026gt;20% reduction in weight relative to conventional loose-tube cables, allowing for greater fiber density and cable packing within a duct\u003c\/li\u003e\n\u003cli\u003eUL listed in accordance with NEC 770.179(b) for use in vertical runs in building risers or from floor to floor\u003c\/li\u003e\n\u003cli\u003eCore-Locked™ outer jacket design for installation survivability\u003c\/li\u003e\n\u003cli\u003eHelically stranded core for greater flexibility and mechanical protection of the optical fibers\u003c\/li\u003e\n\u003cli\u003eCable offers a cost savings by eliminating the need to splice outdoor cable at building entrance\u003c\/li\u003e\n\u003cli\u003eCable can be terminated with 900µm fanout kit for LC connectorization\u003c\/li\u003e\n\u003cli\u003eConstruction options available for direct termination of tight-buffered fiber units to MPO\/MTP connectors\u003c\/li\u003e\n\u003cli\u003eSuitable for direct pulling with wire mesh grips\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eSpecifications\u003c\/h4\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0079\/8874\/0186\/files\/OCC-Ultra-Fox-perf_chart-1.pdf?1946\" target=\"_blank\"\u003e \u003cbutton class=\"download-btn\"\u003eFiber Performance Chart\u003c\/button\u003e \u003c\/a\u003e\u003c\/p\u003e\n\u003ch3\u003eJacket Characteristics\u003c\/h3\u003e\n\u003ctable class=\"table table-bordered\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd width=\"25%\"\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-40ºC to +85ºC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStorage Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-55ºC to +85ºC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInstallation Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-20ºC to +60ºC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFlame Retardancy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUL Listed Type OFNR (UL 1666)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCrush Resistance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1,800 N\/cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFlex Resistance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2,000 cycles\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003ctable class=\"OCCSpecTable\" cellspacing=\"0\" align=\"center\"\u003e\n\u003ctbody\u003e\n\u003ctr class=\"tablePadding tablePaddingHeader\" align=\"center\"\u003e\n\u003ctd rowspan=\"2\"\u003eFiber Count\u003c\/td\u003e\n\u003ctd rowspan=\"2\"\u003eDiameter\u003cbr\u003emm (in)\u003c\/td\u003e\n\u003ctd rowspan=\"2\"\u003eWeight\u003cbr\u003ekg\/km (lbs\/1,000ft)\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eTensile Load\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eMinimum Bend Radius\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"tablePadding tablePaddingHeader\" align=\"center\"\u003e\n\u003ctd\u003eInstallation N (lbs)\u003c\/td\u003e\n\u003ctd\u003eOperational N (lbs)\u003c\/td\u003e\n\u003ctd\u003eInstallation cm (in)\u003c\/td\u003e\n\u003ctd\u003eOperational cm (in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"tablePadding\" align=\"center\"\u003e\n\u003ctd\u003e24\u003c\/td\u003e\n\u003ctd\u003e7.6 (0.30)\u003c\/td\u003e\n\u003ctd\u003e75 (50)\u003c\/td\u003e\n\u003ctd\u003e2,700 (600)\u003c\/td\u003e\n\u003ctd\u003e600 (135)\u003c\/td\u003e\n\u003ctd\u003e11.4 (4.5)\u003c\/td\u003e\n\u003ctd\u003e7.6 (3.0)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"tablePadding\" align=\"center\" bgcolor=\"#cccccc\"\u003e\n\u003ctd\u003e48\u003c\/td\u003e\n\u003ctd\u003e7.6 (0.30)\u003c\/td\u003e\n\u003ctd\u003e75 (50)\u003c\/td\u003e\n\u003ctd\u003e2,700 (600)\u003c\/td\u003e\n\u003ctd\u003e600 (135)\u003c\/td\u003e\n\u003ctd\u003e11.4 (4.5)\u003c\/td\u003e\n\u003ctd\u003e7.6 (3.0)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"tablePadding\" align=\"center\"\u003e\n\u003ctd\u003e72\u003c\/td\u003e\n\u003ctd\u003e9.0 (0.35)\u003c\/td\u003e\n\u003ctd\u003e97 (65)\u003c\/td\u003e\n\u003ctd\u003e2,700 (600)\u003c\/td\u003e\n\u003ctd\u003e600 (135)\u003c\/td\u003e\n\u003ctd\u003e13.5 (5.3)\u003c\/td\u003e\n\u003ctd\u003e9.0 (3.5)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"tablePadding\" align=\"center\" bgcolor=\"#cccccc\"\u003e\n\u003ctd\u003e96\u003c\/td\u003e\n\u003ctd\u003e10.3 (0.40)\u003c\/td\u003e\n\u003ctd\u003e116 (78)\u003c\/td\u003e\n\u003ctd\u003e2,700 (600)\u003c\/td\u003e\n\u003ctd\u003e600 (135)\u003c\/td\u003e\n\u003ctd\u003e15.5 (6.0)\u003c\/td\u003e\n\u003ctd\u003e10.3 (4.0)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"tablePadding\" align=\"center\"\u003e\n\u003ctd\u003e120\u003c\/td\u003e\n\u003ctd\u003e11.4 (0.45)\u003c\/td\u003e\n\u003ctd\u003e141 (95)\u003c\/td\u003e\n\u003ctd\u003e3,000 (670)\u003c\/td\u003e\n\u003ctd\u003e1,000 (220)\u003c\/td\u003e\n\u003ctd\u003e17.1 (6.8)\u003c\/td\u003e\n\u003ctd\u003e11.4 (4.5)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"tablePadding\" align=\"center\" bgcolor=\"#cccccc\"\u003e\n\u003ctd\u003e144\u003c\/td\u003e\n\u003ctd\u003e11.7 (0.46)\u003c\/td\u003e\n\u003ctd\u003e152 (102)\u003c\/td\u003e\n\u003ctd\u003e3,000 (670)\u003c\/td\u003e\n\u003ctd\u003e1,000 (220)\u003c\/td\u003e\n\u003ctd\u003e17.6 (6.9)\u003c\/td\u003e\n\u003ctd\u003e11.7 (4.6)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"tablePadding\" align=\"center\"\u003e\n\u003ctd\u003e168\u003c\/td\u003e\n\u003ctd\u003e14.1 (0.56)\u003c\/td\u003e\n\u003ctd\u003e208 (140)\u003c\/td\u003e\n\u003ctd\u003e4,800 (1,080)\u003c\/td\u003e\n\u003ctd\u003e1,600 (360)\u003c\/td\u003e\n\u003ctd\u003e17.6 (6.9)\u003c\/td\u003e\n\u003ctd\u003e11.7 (4.6)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"tablePadding\" align=\"center\" bgcolor=\"#cccccc\"\u003e\n\u003ctd\u003e192\u003c\/td\u003e\n\u003ctd\u003e12.9 (0.51)\u003c\/td\u003e\n\u003ctd\u003e179 (120)\u003c\/td\u003e\n\u003ctd\u003e4,800 (1,080)\u003c\/td\u003e\n\u003ctd\u003e1,600 (360)\u003c\/td\u003e\n\u003ctd\u003e19.4 (7.7)\u003c\/td\u003e\n\u003ctd\u003e12.9 (5.1)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"tablePadding\" align=\"center\"\u003e\n\u003ctd\u003e216\u003c\/td\u003e\n\u003ctd\u003e12.9 (0.51)\u003c\/td\u003e\n\u003ctd\u003e179 (120)\u003c\/td\u003e\n\u003ctd\u003e4,800 (1,080)\u003c\/td\u003e\n\u003ctd\u003e1,600 (360)\u003c\/td\u003e\n\u003ctd\u003e19.4 (7.7)\u003c\/td\u003e\n\u003ctd\u003e12.9 (5.1)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"tablePadding\" align=\"center\" bgcolor=\"#cccccc\"\u003e\n\u003ctd\u003e288\u003c\/td\u003e\n\u003ctd\u003e15.0 (0.60)\u003c\/td\u003e\n\u003ctd\u003e226 (152)\u003c\/td\u003e\n\u003ctd\u003e5,400 (1,210)\u003c\/td\u003e\n\u003ctd\u003e1,800 (400)\u003c\/td\u003e\n\u003ctd\u003e22.58 (9.0)\u003c\/td\u003e\n\u003ctd\u003e15.0 (6.0)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp class=\"impNote\"\u003eInstallation loads in excess of 2,700 N (600 lbs) are not recommended. Contact us for ordering details.\u003c\/p\u003e\n\u003ch4\u003eMultimode Fiber Information\u003c\/h4\u003e\n\u003cp\u003eMulti-Mode cable commonly has a diameter in the 50-to-100 micron range (typical multimode fiber core diameters are 50 or 62.5 micrometers). Multimode fiber gives you high bandwidth at high speeds (10 to 100MBS - Gigabit to 275m to 2km) over medium distances. Light waves are dispersed into numerous paths, or modes, as they travel through the cable's core typically 850 or 1300nm. However, in long cable runs (greater than 3000 feet [914.4 meters), multiple paths of light can cause signal distortion at the receiving end, resulting in an unclear and incomplete data transmission so designers now call for single mode fiber in new applications using Gigabit and beyond.\u003c\/p\u003e","brand":"OCC","offers":[{"title":"24 Strand","offer_id":31135219122237,"sku":"HC024JWLSCKR","price":0.0,"currency_code":"USD","in_stock":true},{"title":"48 Strand","offer_id":31135219187773,"sku":"HC048JWLSCKR","price":0.0,"currency_code":"USD","in_stock":true},{"title":"72 Strand","offer_id":31135219253309,"sku":"HC072JWLSCKR","price":0.0,"currency_code":"USD","in_stock":true},{"title":"96 Strand","offer_id":31135219318845,"sku":"HC096JWLSCKR","price":0.0,"currency_code":"USD","in_stock":true},{"title":"120 Strand","offer_id":31135219351613,"sku":"HC120JWLSCKR","price":0.0,"currency_code":"USD","in_stock":true},{"title":"144 Strand","offer_id":31135219449917,"sku":"HC144JWLSCKR","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0252\/1897\/3741\/products\/HighDensity-Black_605791f5-b5eb-4dd9-ab85-38d58300aac9.png?v=1567190849"},{"product_id":"high-density-fiber-optic-cable-single-mode-9125-indooroutdoor-riser","title":"High-Density Riser Fiber Optic Cable, Single Mode, Indoor\/Outdoor","description":"\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0252\/1897\/3741\/files\/Made_In_USA.png?2208\" alt=\"Made in USA\" width=\"115px\" height=\"65px\" class=\"bulleticons\"\u003e \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0252\/1897\/3741\/files\/UL_LISTED_LOGO_US.png?2209\" alt=\"UL Listed\" width=\"76px\" height=\"65px\" class=\"bulleticons\"\u003e \u003cmeta charset=\"utf-8\"\u003e\n\u003ch3\u003e(We do not offer credits or returns for this item.)\u003c\/h3\u003e\n\u003cp\u003e\u003cem\u003eTo order this cable, please see the \u003cstrong\u003eProduct Options\u003c\/strong\u003e tab below and choose the strand count and length needed.\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIf you would like to inquire about our custom fiber cable options such as terminated ends, pulleyes, and custom cut lengths, please call us.\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch4\u003eDescription\u003c\/h4\u003e\n\u003ch2\u003eHigh-Density Fiber Optic Cable, Single Mode, 9\/125, Indoor\/Outdoor, Riser\u003c\/h2\u003e\n\u003cp\u003eThe new high density fiber cable is extraordinary. There is nothing else like it. Like loose-tube gel-filled cables, it utilizes 245 um fibers as opposed to 900 um tight buffered fibers and it does require breakout kits, but instead uses special \u003ca href=\"\/store\/p\/8291-Fan-out-Kit-12-Fiber-24-Leads-900um-Tubing-High-density-Cable-Only.aspx\" target=\"_blank\" rel=\"noopener noreferrer\"\u003e12 fiber fan-out kits\u003c\/a\u003e and a \u003ca href=\"\/store\/p\/8292-Fiber-Slitter-and-Stripper-2-2mm-Outer-Jacket-245um-Fiber.aspx\" target=\"_blank\" rel=\"noopener noreferrer\"\u003efiber stripper\/slitter\u003c\/a\u003e to terminate. The high density fiber cable's water resistance characteristics surpass loose tube cables.\u003c\/p\u003e\n\u003cp\u003eWith the high-density fiber cables, the 245 um fibers are encapsulated within a tight buffer. Easily prepared for termination, high-density cables feature the smallest outer diameter within the industry and still retain rugged characteristics: lightweight, flexible, and easy to work with and at a crush rating of 1800 N\/cm and a flex rating of 2,000 cycles!\u003c\/p\u003e\n\u003cp\u003eCleaning your fiber connector end faces and components regularly is crucial for avoiding a total network failure. Ensure your optical fiber system is working properly and prevent major network issues with \u003ca href=\"https:\/\/www.primuscable.com\/collections\/fiber-cleaning-kit\" alt=\"Fiber Cleaning Kits\" target=\"_blank\"\u003e\u003cstrong\u003e fiber cleaning kits,\u003c\/strong\u003e\u003c\/a\u003e \u003ca href=\"https:\/\/www.primuscable.com\/collections\/fiber-cleaning-pens\" alt=\"Fiber Cleaning Pens\" target=\"_blank\"\u003e\u003cstrong\u003e pens,\u003c\/strong\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/www.primuscable.com\/collections\/fiber-cleaning-fluids\" alt=\"Fiber Cleaning Fluids\" target=\"_blank\"\u003e\u003cstrong\u003e fluids,\u003c\/strong\u003e\u003c\/a\u003e and \u003ca href=\"https:\/\/www.primuscable.com\/collections\/fiber-cleaning-wipes\" alt=\"Fiber Cleaning Wipes\" target=\"_blank\"\u003e\u003cstrong\u003ewipes.\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003ch4\u003eFeatures\u003c\/h4\u003e\n\u003ch3\u003eApplications:\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDesigned for installation in an underground duct for data transmission between nodes or hubs\u003c\/li\u003e\n\u003cli\u003eCable can also be routed vertically inside buildings\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFeatures:\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eRugged tight-buffered fiber unit construction\u003c\/li\u003e\n\u003cli\u003eCable materials are indoor\/outdoor: UV, fungus, and water resistant\u003c\/li\u003e\n\u003cli\u003eThe high-density breakout cables offer a \u0026gt;20% reduction in diameter and a \u0026gt;20% reduction in weight relative to conventional loose-tube cables, allowing for greater fiber density and cable packing within a duct\u003c\/li\u003e\n\u003cli\u003eUL listed in accordance with NEC 770.179(b) for use in vertical runs in building risers or from floor to floor\u003c\/li\u003e\n\u003cli\u003eCore-Locked™ outer jacket design for installation survivability\u003c\/li\u003e\n\u003cli\u003eHelically stranded core for greater flexibility and mechanical protection of the optical fibers\u003c\/li\u003e\n\u003cli\u003eCable offers a cost savings by eliminating the need to splice outdoor cable at building entrance\u003c\/li\u003e\n\u003cli\u003eCable can be terminated with 900™m fanout kit for LC connectorization\u003c\/li\u003e\n\u003cli\u003eConstruction options available for direct termination of tight-buffered fiber units to MPO\/MTP connectors\u003c\/li\u003e\n\u003cli\u003eSuitable for direct pulling with wire mesh grips\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eSpecifications\u003c\/h4\u003e\n\n\u003cp\u003e\n   \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0079\/8874\/0186\/files\/OCC-Ultra-Fox-perf_chart-1.pdf?1946\" target=\"_blank\"\u003e\n      \u003cbutton class=\"download-btn\"\u003eFiber Performance Chart\u003c\/button\u003e\n   \u003c\/a\u003e\n\u003c\/p\u003e\n\n\u003ch3\u003eJacket Characteristics\u003c\/h3\u003e\n\u003ctable class=\"table table-bordered\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd width=\"25%\"\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-40ºC to +85ºC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStorage Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-55ºC to +85ºC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInstallation Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-20ºC to +60ºC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFlame Retardancy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUL Listed Type OFNR (UL 1666)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCrush Resistance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1,800 N\/cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFlex Resistance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2,000 cycles\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable class=\"OCCSpecTable\" cellspacing=\"0\" align=\"center\"\u003e\n\u003ctbody\u003e\n\u003ctr class=\"tablePadding tablePaddingHeader\" align=\"center\"\u003e\n\u003ctd rowspan=\"2\"\u003eFiber Count\u003c\/td\u003e\n\u003ctd rowspan=\"2\"\u003eDiameter\u003cbr\u003emm (in)\u003c\/td\u003e\n\u003ctd rowspan=\"2\"\u003eWeight\u003cbr\u003ekg\/km (lbs\/1,000ft)\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eTensile Load\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eMinimum Bend Radius\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"tablePadding tablePaddingHeader\" align=\"center\"\u003e\n\u003ctd\u003eInstallation N (lbs)\u003c\/td\u003e\n\u003ctd\u003eOperational N (lbs)\u003c\/td\u003e\n\u003ctd\u003eInstallation cm (in)\u003c\/td\u003e\n\u003ctd\u003eOperational cm (in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"tablePadding\" align=\"center\"\u003e\n\u003ctd\u003e24\u003c\/td\u003e\n\u003ctd\u003e7.6 (0.30)\u003c\/td\u003e\n\u003ctd\u003e75 (50)\u003c\/td\u003e\n\u003ctd\u003e2,700 (600)\u003c\/td\u003e\n\u003ctd\u003e600 (135)\u003c\/td\u003e\n\u003ctd\u003e11.4 (4.5)\u003c\/td\u003e\n\u003ctd\u003e7.6 (3.0)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"tablePadding\" align=\"center\" bgcolor=\"#cccccc\"\u003e\n\u003ctd\u003e48\u003c\/td\u003e\n\u003ctd\u003e7.6 (0.30)\u003c\/td\u003e\n\u003ctd\u003e75 (50)\u003c\/td\u003e\n\u003ctd\u003e2,700 (600)\u003c\/td\u003e\n\u003ctd\u003e600 (135)\u003c\/td\u003e\n\u003ctd\u003e11.4 (4.5)\u003c\/td\u003e\n\u003ctd\u003e7.6 (3.0)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"tablePadding\" align=\"center\"\u003e\n\u003ctd\u003e72\u003c\/td\u003e\n\u003ctd\u003e9.0 (0.35)\u003c\/td\u003e\n\u003ctd\u003e97 (65)\u003c\/td\u003e\n\u003ctd\u003e2,700 (600)\u003c\/td\u003e\n\u003ctd\u003e600 (135)\u003c\/td\u003e\n\u003ctd\u003e13.5 (5.3)\u003c\/td\u003e\n\u003ctd\u003e9.0 (3.5)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"tablePadding\" align=\"center\" bgcolor=\"#cccccc\"\u003e\n\u003ctd\u003e96\u003c\/td\u003e\n\u003ctd\u003e10.3 (0.40)\u003c\/td\u003e\n\u003ctd\u003e116 (78)\u003c\/td\u003e\n\u003ctd\u003e2,700 (600)\u003c\/td\u003e\n\u003ctd\u003e600 (135)\u003c\/td\u003e\n\u003ctd\u003e15.5 (6.0)\u003c\/td\u003e\n\u003ctd\u003e10.3 (4.0)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"tablePadding\" align=\"center\"\u003e\n\u003ctd\u003e120\u003c\/td\u003e\n\u003ctd\u003e11.4 (0.45)\u003c\/td\u003e\n\u003ctd\u003e141 (95)\u003c\/td\u003e\n\u003ctd\u003e3,000 (670)\u003c\/td\u003e\n\u003ctd\u003e1,000 (220)\u003c\/td\u003e\n\u003ctd\u003e17.1 (6.8)\u003c\/td\u003e\n\u003ctd\u003e11.4 (4.5)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"tablePadding\" align=\"center\" bgcolor=\"#cccccc\"\u003e\n\u003ctd\u003e144\u003c\/td\u003e\n\u003ctd\u003e11.7 (0.46)\u003c\/td\u003e\n\u003ctd\u003e152 (102)\u003c\/td\u003e\n\u003ctd\u003e3,000 (670)\u003c\/td\u003e\n\u003ctd\u003e1,000 (220)\u003c\/td\u003e\n\u003ctd\u003e17.6 (6.9)\u003c\/td\u003e\n\u003ctd\u003e11.7 (4.6)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"tablePadding\" align=\"center\"\u003e\n\u003ctd\u003e168\u003c\/td\u003e\n\u003ctd\u003e14.1 (0.56)\u003c\/td\u003e\n\u003ctd\u003e208 (140)\u003c\/td\u003e\n\u003ctd\u003e4,800 (1,080)\u003c\/td\u003e\n\u003ctd\u003e1,600 (360)\u003c\/td\u003e\n\u003ctd\u003e17.6 (6.9)\u003c\/td\u003e\n\u003ctd\u003e11.7 (4.6)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"tablePadding\" align=\"center\" bgcolor=\"#cccccc\"\u003e\n\u003ctd\u003e192\u003c\/td\u003e\n\u003ctd\u003e12.9 (0.51)\u003c\/td\u003e\n\u003ctd\u003e179 (120)\u003c\/td\u003e\n\u003ctd\u003e4,800 (1,080)\u003c\/td\u003e\n\u003ctd\u003e1,600 (360)\u003c\/td\u003e\n\u003ctd\u003e19.4 (7.7)\u003c\/td\u003e\n\u003ctd\u003e12.9 (5.1)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"tablePadding\" align=\"center\"\u003e\n\u003ctd\u003e216\u003c\/td\u003e\n\u003ctd\u003e12.9 (0.51)\u003c\/td\u003e\n\u003ctd\u003e179 (120)\u003c\/td\u003e\n\u003ctd\u003e4,800 (1,080)\u003c\/td\u003e\n\u003ctd\u003e1,600 (360)\u003c\/td\u003e\n\u003ctd\u003e19.4 (7.7)\u003c\/td\u003e\n\u003ctd\u003e12.9 (5.1)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"tablePadding\" align=\"center\" bgcolor=\"#cccccc\"\u003e\n\u003ctd\u003e288\u003c\/td\u003e\n\u003ctd\u003e15.0 (0.60)\u003c\/td\u003e\n\u003ctd\u003e226 (152)\u003c\/td\u003e\n\u003ctd\u003e5,400 (1,210)\u003c\/td\u003e\n\u003ctd\u003e1,800 (400)\u003c\/td\u003e\n\u003ctd\u003e22.58 (9.0)\u003c\/td\u003e\n\u003ctd\u003e15.0 (6.0)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp class=\"impNote\"\u003eInstallation loads in excess of 2,700 N (600 lbs) are not recommended. Contact us for ordering details.\u003c\/p\u003e\n\u003ch4\u003eMultimode Fiber Information\u003c\/h4\u003e\n\u003cp\u003eMulti-Mode cable commonly has a diameter in the 50-to-100 micron range (typical multimode fiber core diameters are 50 or 62.5 micrometers). Multimode fiber gives you high bandwidth at high speeds (10 to 100MBS - Gigabit to 275m to 2km) over medium distances. Light waves are dispersed into numerous paths, or modes, as they travel through the cable's core typically 850 or 1300nm. However, in long cable runs (greater than 3000 feet [914.4 meters), multiple paths of light can cause signal distortion at the receiving end, resulting in an unclear and incomplete data transmission so designers now call for single mode fiber in new applications using Gigabit and beyond.\u003c\/p\u003e","brand":"OCC","offers":[{"title":"24 Strand","offer_id":31086151204925,"sku":"HC024JSLACKR","price":0.0,"currency_code":"USD","in_stock":true},{"title":"48 Strand","offer_id":31086151237693,"sku":"HC048JSLACKR","price":0.0,"currency_code":"USD","in_stock":true},{"title":"72 Strand","offer_id":31086151270461,"sku":"HC072JSLACKR","price":0.0,"currency_code":"USD","in_stock":true},{"title":"96 Strand","offer_id":31086151303229,"sku":"HC096JSLACKR","price":0.0,"currency_code":"USD","in_stock":true},{"title":"120 Strand","offer_id":31086151335997,"sku":"HC120JSLACKR","price":0.0,"currency_code":"USD","in_stock":true},{"title":"144 Strand","offer_id":31086151368765,"sku":"HC144JSLACKR","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0252\/1897\/3741\/products\/HighDensity-Black_b512c238-a32c-4082-b4d7-9caa98c47b8e.png?v=1567190849"},{"product_id":"military-fiber-optic-cable-multimode-62-5125-om1-outdoor-tactical-breakout-polyurethane","title":"Military Polyurethane Fiber Optic Cable, Multimode OM1, Outdoor Tactical Breakout","description":"\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0252\/1897\/3741\/files\/Made_In_USA.png?2208\" alt=\"Made in USA\" width=\"115px\" height=\"65px\" style=\"background-color: #fff; border-radius: 10px; padding: 5px;\"\u003e \u003cmeta charset=\"utf-8\"\u003e\u003c\/p\u003e\n\u003ch3\u003e(We do not offer credits or returns for this item.)\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eIf you would like to inquire about our custom fiber cable options such as terminated ends, pulleyes, and custom cut lengths, please call or email us.\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch4\u003eDescription\u003c\/h4\u003e\n\u003ch2\u003eMilitary Fiber Optic Cable, Multimode, 62.5\/125 OM1, Outdoor Tactical Breakout, Polyurethane\u003c\/h2\u003e\n\u003cp\u003eThis Multimode OM1 62.5\/125 Military Tactical Breakout Cable is ideal for outdoor applications where deployment and retrieval for reuse is required. Having an extremely strong, lightweight and rugged design, the mil tac multimode OM1 cable is designed for military tactical field use and commercial applications. The 2.0mm subcables allow for easy direct terminations of fiber connectors on each individually jacketed strand. These tactical breakout fiber cables have been tested for and are currently in use in military data communication applications worldwide.\u003c\/p\u003e\n\u003cp\u003eWith options to be prespooled on deployable reels for a ready-to-use product and pre-terminated with single fiber or ruggedized multichannel connectors, these military tactical cables can be customized to your specific application.\u003c\/p\u003e\n\u003cp\u003eCleaning your fiber connector end faces and components regularly is crucial for avoiding a total network failure. Ensure your optical fiber system is working properly and prevent major network issues with \u003ca href=\"https:\/\/www.primuscable.com\/collections\/fiber-cleaning-kit\" alt=\"Fiber Cleaning Kits\" target=\"_blank\"\u003e\u003cstrong\u003e fiber cleaning kits,\u003c\/strong\u003e\u003c\/a\u003e \u003ca href=\"https:\/\/www.primuscable.com\/collections\/fiber-cleaning-pens\" alt=\"Fiber Cleaning Pens\" target=\"_blank\"\u003e\u003cstrong\u003e pens,\u003c\/strong\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/www.primuscable.com\/collections\/fiber-cleaning-fluids\" alt=\"Fiber Cleaning Fluids\" target=\"_blank\"\u003e\u003cstrong\u003e fluids,\u003c\/strong\u003e\u003c\/a\u003e and \u003ca href=\"https:\/\/www.primuscable.com\/collections\/fiber-cleaning-wipes\" alt=\"Fiber Cleaning Wipes\" target=\"_blank\"\u003e\u003cstrong\u003ewipes.\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003ch4\u003eFeatures\u003c\/h4\u003e\n\u003ch3\u003e\u003cspan style=\"text-decoration: underline;\"\u003eFeatures\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eExtremely strong, lightweight, rugged, survivable tight-buffered cables designed for military tactical field use and commercial applications\u003c\/li\u003e\n\u003cli\u003ePolyurethane jacketed for abrasion, cut and chemical resistance\u003c\/li\u003e\n\u003cli\u003eCore-locked jacket for improved mechanical performance\u003c\/li\u003e\n\u003cli\u003eBreakout cable design with individual color-coded subcables protecting each optical fiber\u003c\/li\u003e\n\u003cli\u003eCrush resistant and resilient, with two seperate layers of aramid strength members in the subcables for individual single-fiber connector and termination pin, and overall for termination to multiway connector backshells or other housing\u003c\/li\u003e\n\u003cli\u003eHelically stranded cable core for flexibility, deployment survivability and exceptional mechanical protection for the optical fibers\u003c\/li\u003e\n\u003cli\u003eCables have been tested and are in use in military data communications applications worldwide\u003c\/li\u003e\n\u003cli\u003eCan be used outdoors for temporary deployment directly on the ground, in all terrains, including severe environments\u003c\/li\u003e\n\u003cli\u003eSuitable for industrial, mining and petrochemical environments - chemical resistant\u003c\/li\u003e\n\u003cli\u003eRound cable design for easy installation and survivability\u003c\/li\u003e\n\u003cli\u003eIdeally suited for use with MIL-C-38999 style military connectors - subcables terminate to individual pins and overall aramid strength member terminates to backshell\u003c\/li\u003e\n\u003cli\u003e2.0 mm subcables standard\u003c\/li\u003e\n\u003cli\u003eTactical Polyurethane (C) outer jacket material is standard. Flame- retardant tactical (V) and Low-Smoke Zero-Halogen (G) outer jacket materials are available\u003c\/li\u003e\n\u003cli\u003eUltra-Fox Plus fiber used for the ultimate environmental and mechanical protection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eGround-tactical cable that is ideal for use in harsh environments where deployment and retrieval for reuse is required\u003c\/li\u003e\n\u003cli\u003eIdeal for applications that require termination of the subcables to a connector\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eOptions\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMil-Tac cables prespooled on deployable reels for a ready-to-use product\u003c\/li\u003e\n\u003cli\u003eMil-Tac cables can be pre-terminated with single-fiber or ruggedized multichannel connectors upon request\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eSpecifications\u003c\/h4\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0079\/8874\/0186\/files\/OCC_Mil-Tac_Break_Fiber.pdf?3711\" target=\"_blank\"\u003e \u003cbutton class=\"download-btn\"\u003eSpec Sheet\u003c\/button\u003e \u003c\/a\u003e \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0079\/8874\/0186\/files\/OCC-Ultra-Fox-perf_chart-1.pdf?1946\" target=\"_blank\"\u003e \u003cbutton class=\"download-btn\"\u003eFiber Performance Chart\u003c\/button\u003e \u003c\/a\u003e \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0079\/8874\/0186\/files\/OCC-Mil-Tac_Installation-General_Guidelines_Rev_B-1.pdf?3926\" target=\"_blank\"\u003e \u003cbutton class=\"download-btn\"\u003eGeneral Guidelines\u003c\/button\u003e \u003c\/a\u003e \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0079\/8874\/0186\/files\/OCC-Mil-Tac_Fiber_Optic_Field_Testing_Guidelines_Rev_A-1.pdf?3926\" target=\"_blank\"\u003e \u003cbutton class=\"download-btn\"\u003eTesting Guidelines\u003c\/button\u003e \u003c\/a\u003e \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0079\/8874\/0186\/files\/OCC-Mil-Tac_Storage_Handling_Rev_B-1.pdf?3926\" target=\"_blank\"\u003e \u003cbutton class=\"download-btn\"\u003eStorage Handling\u003c\/button\u003e \u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch3\u003eJacket Characteristics\u003c\/h3\u003e\n\u003cdiv class=\"spec-style-1-0\"\u003eOperating Temperature: -55ºC to +85ºC\u003c\/div\u003e\n\u003cdiv class=\"spec-style-2-0\"\u003eStorage Temperature: -70ºC to +85ºC\u003c\/div\u003e\n\u003cdiv class=\"spec-style-1-0\"\u003eCrush Resistance: 440 N\/cm (EIA\/TIA-455-41A military requirements)\u003c\/div\u003e\n\u003cdiv class=\"spec-style-2-0\"\u003eImpact Resistance: 200 impacts (EIA\/TIA-455-25A military requirements)\u003c\/div\u003e\n\u003cdiv class=\"spec-style-1-0\"\u003eFlex Resistance: 2,000 cycles (EIA\/TIA-455-104A military requirements)\u003c\/div\u003e\n\u003cdiv class=\"spec-clear\"\u003e\u003cbr\u003e\u003c\/div\u003e","brand":"OCC","offers":[{"title":"2 Strand","offer_id":30010701742125,"sku":"B-002CWST5KM","price":0.0,"currency_code":"USD","in_stock":true},{"title":"6 Strand","offer_id":31414994075709,"sku":"B-006CWST5KM","price":0.0,"currency_code":"USD","in_stock":true},{"title":"12 Strand","offer_id":31414996336701,"sku":"B-012CWST5KM","price":0.0,"currency_code":"USD","in_stock":true},{"title":"24 Strand","offer_id":31415016325181,"sku":"B-024CWST5KM","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0252\/1897\/3741\/products\/Breakout-IO_b774db65-a356-43eb-b16f-3e3144012137.png?v=1567190849"},{"product_id":"broadcast-fiber-optic-cable-multimode-62-5125-om1-outdoor-distribution-tactical-polyurethane","title":"Tight Buffer Outdoor Broadcast Distribution Tactical Polyurethane Fiber Optic Cable, Multimode, OM1","description":"\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0252\/1897\/3741\/files\/Made_In_USA.png?2208\" alt=\"Made in USA\" class=\"bulleticons\" width=\"115px\" height=\"65px\"\u003e\u003c\/p\u003e\n\u003ch3\u003eWe do not offer credits or returns for this item.\u003c\/h3\u003e\n\u003ch3\u003eThis fiber cable is priced per foot and may include a minimum order length.\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eIf you would like to inquire about our custom fiber cable options such as terminated ends, pulleyes, and custom cut lengths, please call or email us.\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch4\u003eDescription\u003c\/h4\u003e\n\u003ch2\u003eBroadcast Multimode OM1 Broadcast Distribution Tactical Fiber Optic Cable\u003c\/h2\u003e\n\u003cp\u003eThis Distribution Field Broadcast MultiMode OM1 62.5\/125 Fiber Cable can be used outdoors for temporary deployment directly on the ground in all terrains, including severe environments and has been tested to be used in broadcast data communications applications worldwide. The extremely strong, lightweight, rugged, survivable tight-buffered cables are designed for broadcast field use and commercial applications. This broadcast distribution cable is crush resistant and resilient with a thick layer of aramid strength members.\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eCleaning your fiber connector end faces and components regularly is crucial for avoiding a total network failure. Ensure your optical fiber system is working properly and prevent major network issues with \u003c\/span\u003e\u003ca href=\"https:\/\/www.primuscable.com\/collections\/fiber-cleaning-kit\" alt=\"Fiber Cleaning Kits\" target=\"_blank\"\u003e\u003cstrong\u003efiber cleaning kits,\u003c\/strong\u003e\u003c\/a\u003e\u003cspan\u003e \u003c\/span\u003e\u003ca href=\"https:\/\/www.primuscable.com\/collections\/fiber-cleaning-pens\" alt=\"Fiber Cleaning Pens\" target=\"_blank\"\u003e\u003cstrong\u003epens,\u003c\/strong\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/www.primuscable.com\/collections\/fiber-cleaning-fluids\" alt=\"Fiber Cleaning Fluids\" target=\"_blank\"\u003e\u003cstrong\u003e\u003cspan\u003e \u003c\/span\u003efluids,\u003c\/strong\u003e\u003c\/a\u003e\u003cspan\u003e and \u003c\/span\u003e\u003ca href=\"https:\/\/www.primuscable.com\/collections\/fiber-cleaning-wipes\" alt=\"Fiber Cleaning Wipes\" target=\"_blank\"\u003e\u003cstrong\u003ewipes.\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDeployable cable that is ideal for use in harsh environments where deployment and retrieval for reuse are required\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eFeatures\u003c\/h4\u003e\n\u003ch3\u003e\u003cspan style=\"text-decoration: underline;\"\u003eFeatures\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eExtremely strong, lightweight, rugged, survivable tight-buffered cables are designed for broadcast field use and commercial applications\u003c\/li\u003e\n\u003cli\u003eCompact, round cable design for ease of transportation and deployment\u003c\/li\u003e\n\u003cli\u003eCore-locked jacket for improved mechanical performance\u003c\/li\u003e\n\u003cli\u003eDesigned for use in adverse environments where reduced size and weight are important\u003c\/li\u003e\n\u003cli\u003eHelically stranded cable core for flexibility, survival in difficult pulls, and exceptional mechanical protection for the optical fibers\u003c\/li\u003e\n\u003cli\u003eCables have been tested and are in use in broadcast data communications applications worldwide\u003c\/li\u003e\n\u003cli\u003eCan be used outdoors for temporary deployment directly on the ground in all terrains, including severe environments\u003c\/li\u003e\n\u003cli\u003eSuitable for industrial, mining and petrochemical environments; chemical resistant\u003c\/li\u003e\n\u003cli\u003eCrush resistant and resilient with a thick layer of aramid strength members\u003c\/li\u003e\n\u003cli\u003ePolyurethane jacketed for abrasion, cut and chemical resistance\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eSpecifications\u003c\/h4\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0079\/8874\/0186\/files\/OCC_Distribution_MM_Specs.pdf?3926\" target=\"_blank\"\u003e \u003cbutton class=\"download-btn\"\u003eSpec Sheet\u003c\/button\u003e \u003c\/a\u003e \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0079\/8874\/0186\/files\/OCC-Ultra-Fox-perf_chart-1.pdf?1946\" target=\"_blank\"\u003e \u003cbutton class=\"download-btn\"\u003eFiber Performance Chart\u003c\/button\u003e \u003c\/a\u003e \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0079\/8874\/0186\/files\/OCC-Mil-Tac_Installation-General_Guidelines_Rev_B-1.pdf?3926\" target=\"_blank\"\u003e \u003cbutton class=\"download-btn\"\u003eGeneral Guidelines\u003c\/button\u003e \u003c\/a\u003e \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0079\/8874\/0186\/files\/OCC-Mil-Tac_Fiber_Optic_Field_Testing_Guidelines_Rev_A-1.pdf?3926\" target=\"_blank\"\u003e \u003cbutton class=\"download-btn\"\u003eTesting Guidelines\u003c\/button\u003e \u003c\/a\u003e \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0079\/8874\/0186\/files\/OCC-Mil-Tac_Storage_Handling_Rev_B-1.pdf?3926\" target=\"_blank\"\u003e \u003cbutton class=\"download-btn\"\u003eStorage Handling\u003c\/button\u003e \u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch3\u003eJacket Characteristics\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eOperating Temperature: -40ºC to +85ºC\u003c\/li\u003e\n\u003cli\u003eStorage Temperature: -70ºC to +85ºC\u003c\/li\u003e\n\u003cli\u003eCrush Resistance: 1,800 N\/cm\u003c\/li\u003e\n\u003cli\u003eImpact Resistance: 1,500 impacts\u003c\/li\u003e\n\u003cli\u003eFlex Resistance: 2,000 cycles\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"OCC","offers":[{"title":"2 Strand","offer_id":30010555105325,"sku":"DX002CCWLS9KB","price":0.0,"currency_code":"USD","in_stock":true},{"title":"6 Strand","offer_id":31460231675965,"sku":"DX006CWLS9KB","price":0.0,"currency_code":"USD","in_stock":true},{"title":"12 Strand","offer_id":31460231708733,"sku":"DX012CWLS9KB","price":0.0,"currency_code":"USD","in_stock":true},{"title":"24 Strand","offer_id":31460231774269,"sku":"DX024CWLS9KB","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0252\/1897\/3741\/products\/Distribution-IO_312607c5-b978-4453-8d5e-9d62d85917bf.png?v=1567190853"},{"product_id":"broadcast-fiber-optic-cable-single-mode-9125-outdoor-distribution-tactical-polyurethane","title":"Tight Buffer Outdoor Broadcast Distribution Tactical Fiber Optic Cable, OS2 Single Mode, Polyurethane","description":"\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0252\/1897\/3741\/files\/Made_In_USA.png?2208\" alt=\"Made in USA\" class=\"bulleticons\" width=\"115px\" height=\"65px\"\u003e \u003cmeta charset=\"utf-8\"\u003e\u003c\/p\u003e\n\u003ch3\u003e(We do not offer credits or returns for this item.)\u003cbr\u003eThis fiber cable is priced per foot and may include a minimum order length.\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eIf you would like to inquire about our custom fiber cable options such as terminated ends, pulleyes, and custom cut lengths, please call or email us.\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch4\u003eDescription\u003c\/h4\u003e\n\u003ch2\u003eBroadcast Single Mode Distribution Fiber Optic Cable\u003c\/h2\u003e\n\u003cp\u003eThis Distribution Field Broadcast Single Mode OS2 9\/125 Fiber Cable can be used outdoors for temporary deployment directly on the ground in all terrains, including severe environments and has been tested to be used in broadcast data communications applications worldwide. The extremely strong, lightweight, rugged, survivable tight-buffered cables are designed for broadcast field use and commercial applications. This broadcast distribution cable is crush resistant and resilient with a thick layer of aramid strength members.\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eCleaning your fiber connector end faces and components regularly is crucial for avoiding a total network failure. Ensure your optical fiber system is working properly and prevent major network issues with \u003c\/span\u003e\u003ca href=\"https:\/\/www.primuscable.com\/collections\/fiber-cleaning-kit\" alt=\"Fiber Cleaning Kits\" target=\"_blank\"\u003e\u003cstrong\u003efiber cleaning kits,\u003c\/strong\u003e\u003c\/a\u003e\u003cspan\u003e \u003c\/span\u003e\u003ca href=\"https:\/\/www.primuscable.com\/collections\/fiber-cleaning-pens\" alt=\"Fiber Cleaning Pens\" target=\"_blank\"\u003e\u003cstrong\u003epens,\u003c\/strong\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/www.primuscable.com\/collections\/fiber-cleaning-fluids\" alt=\"Fiber Cleaning Fluids\" target=\"_blank\"\u003e\u003cstrong\u003e\u003cspan\u003e \u003c\/span\u003efluids,\u003c\/strong\u003e\u003c\/a\u003e\u003cspan\u003e and \u003c\/span\u003e\u003ca href=\"https:\/\/www.primuscable.com\/collections\/fiber-cleaning-wipes\" alt=\"Fiber Cleaning Wipes\" target=\"_blank\"\u003e\u003cstrong\u003ewipes.\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDeployable cable that is ideal for use in harsh environments where deployment and retrieval for reuse are required\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eFeatures\u003c\/h4\u003e\n\u003ch3\u003e\u003cspan style=\"text-decoration: underline;\"\u003eFeatures\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eExtremely strong, lightweight, rugged, survivable tight-buffered cables are designed for broadcast field use and commercial applications\u003c\/li\u003e\n\u003cli\u003eCompact, round cable design for ease of transportation and deployment\u003c\/li\u003e\n\u003cli\u003eCore-locked jacket for improved mechanical performance\u003c\/li\u003e\n\u003cli\u003eDesigned for use in adverse environments where reduced size and weight are important\u003c\/li\u003e\n\u003cli\u003eHelically stranded cable core for flexibility, survival in difficult pulls, and exceptional mechanical protection for the optical fibers\u003c\/li\u003e\n\u003cli\u003eCables have been tested and are in use in broadcast data communications applications worldwide\u003c\/li\u003e\n\u003cli\u003eCan be used outdoors for temporary deployment directly on the ground in all terrains, including severe environments\u003c\/li\u003e\n\u003cli\u003eSuitable for industrial, mining and petrochemical environments; chemical resistant\u003c\/li\u003e\n\u003cli\u003eCrush resistant and resilient with a thick layer of aramid strength members\u003c\/li\u003e\n\u003cli\u003ePolyurethane jacketed for abrasion, cut and chemical resistance\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eSpecifications\u003c\/h4\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0079\/8874\/0186\/files\/OCC_Distribution_MM_Specs.pdf?3926\" target=\"_blank\"\u003e \u003cbutton class=\"download-btn\"\u003eSpec Sheet\u003c\/button\u003e \u003c\/a\u003e \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0079\/8874\/0186\/files\/OCC-Ultra-Fox-perf_chart-1.pdf?1946\" target=\"_blank\"\u003e \u003cbutton class=\"download-btn\"\u003eFiber Performance Chart\u003c\/button\u003e \u003c\/a\u003e \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0079\/8874\/0186\/files\/OCC-Mil-Tac_Installation-General_Guidelines_Rev_B-1.pdf?3926\" target=\"_blank\"\u003e \u003cbutton class=\"download-btn\"\u003eGeneral Guidelines\u003c\/button\u003e \u003c\/a\u003e \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0079\/8874\/0186\/files\/OCC-Mil-Tac_Fiber_Optic_Field_Testing_Guidelines_Rev_A-1.pdf?3926\" target=\"_blank\"\u003e \u003cbutton class=\"download-btn\"\u003eTesting Guidelines\u003c\/button\u003e \u003c\/a\u003e \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0079\/8874\/0186\/files\/OCC-Mil-Tac_Storage_Handling_Rev_B-1.pdf?3926\" target=\"_blank\"\u003e \u003cbutton class=\"download-btn\"\u003eStorage Handling\u003c\/button\u003e \u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch3\u003eJacket Characteristics\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eOperating Temperature: -40ºC to +85ºC\u003c\/li\u003e\n\u003cli\u003eStorage Temperature: -70ºC to +85ºC\u003c\/li\u003e\n\u003cli\u003eCrush Resistance: 1,800 N\/cm\u003c\/li\u003e\n\u003cli\u003eImpact Resistance: 1,500 impacts\u003c\/li\u003e\n\u003cli\u003eFlex Resistance: 2,000 cycles\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"OCC","offers":[{"title":"2 Strand","offer_id":30010555236397,"sku":"DX002CSLX9KB","price":0.0,"currency_code":"USD","in_stock":true},{"title":"6 Strand","offer_id":31460247732285,"sku":"DX006CSLX9KB","price":0.0,"currency_code":"USD","in_stock":true},{"title":"12 Strand","offer_id":31460247928893,"sku":"DX012CSLX9KB","price":0.0,"currency_code":"USD","in_stock":true},{"title":"24 Strand","offer_id":31460247994429,"sku":"DX024CSLX9KB","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0252\/1897\/3741\/products\/Distribution-IO_7c82d4a4-a7f9-4b7a-9185-82d83e49fd60.png?v=1567190853"},{"product_id":"distribution-fiber-optic-cable-2-strand-multimode-50125-10-gig-om4-indooroutdoor-plenum","title":"Tight Buffer Distribution Plenum Fiber Optic Cable, Multimode 10 Gig OM4, Indoor\/Outdoor","description":"\u003cp\u003e\u003cimg height=\"65px\" width=\"115px\" class=\"bulleticons\" alt=\"Made in USA\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0252\/1897\/3741\/files\/Made_In_USA.png?2208\"\u003e \u003cimg height=\"65px\" width=\"76px\" class=\"bulleticons\" alt=\"UL Listed\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0252\/1897\/3741\/files\/UL_LISTED_LOGO_US.png?2209\"\u003e\u003c\/p\u003e\n\u003ch3\u003eWe do not offer credits or returns for this item.\u003c\/h3\u003e\n\u003ch3\u003eThis fiber cable is priced per foot and may include a minimum order length.\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eIf you would like to inquire about our custom fiber cable options such as terminated ends, pulleyes, and custom cut lengths, please call or email us.\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch4\u003eDescription\u003c\/h4\u003e\n\u003ch2\u003eOCC's Tight Buffer Distribution Plenum Fiber Optic Cable, Multimode 10 Gig OM4, Indoor\/Outdoor\u003c\/h2\u003e\n\u003cp\u003eThis plenum distribution fiber cable is used in trunking, LAN and distribution applications where small size, lightweight, and versatile installation capability are required for ducts, plenums, and air handling spaces. It's ideal for configurations requiring a single termination point with multiple fibers. The plenum distribution fiber optic cable uses high performance components and construction and is UL Listed in accordance with NEC section 770.179(a) for use in ducts, plenums and air-handling spaces.\u003c\/p\u003e\n\u003ch3\u003eMultimode Fiber Information\u003c\/h3\u003e\n\u003cp\u003eMulti-Mode cable commonly has a diameter in the 50-to-100 micron range (typical multimode fiber core diameters are 50 or 62.5 micrometers). Multimode fiber gives you high bandwidth at high speeds (10 to 100MBS - Gigabit to 275m to 2km) over medium distances. Light waves are dispersed into numerous paths, or modes, as they travel through the cable's core typically 850 or 1300nm. However, in long cable runs (greater than 3000 feet [914.4 meters), multiple paths of light can cause signal distortion at the receiving end, resulting in an unclear and incomplete data transmission so designers now call for single mode fiber in new applications using Gigabit and beyond.\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eCleaning your fiber connector end faces and components regularly is crucial for avoiding a total network failure. Ensure your optical fiber system is working properly and prevent major network issues with \u003c\/span\u003e\u003ca alt=\"Fiber Cleaning Kits\" href=\"https:\/\/www.primuscable.com\/collections\/fiber-cleaning-kit\" target=\"_blank\"\u003e\u003cstrong\u003efiber cleaning kits,\u003c\/strong\u003e\u003c\/a\u003e\u003cspan\u003e \u003c\/span\u003e\u003ca alt=\"Fiber Cleaning Pens\" href=\"https:\/\/www.primuscable.com\/collections\/fiber-cleaning-pens\" target=\"_blank\"\u003e\u003cstrong\u003epens,\u003c\/strong\u003e\u003c\/a\u003e\u003ca alt=\"Fiber Cleaning Fluids\" href=\"https:\/\/www.primuscable.com\/collections\/fiber-cleaning-fluids\" target=\"_blank\"\u003e\u003cstrong\u003e\u003cspan\u003e \u003c\/span\u003efluids,\u003c\/strong\u003e\u003c\/a\u003e\u003cspan\u003e and \u003c\/span\u003e\u003ca alt=\"Fiber Cleaning Wipes\" href=\"https:\/\/www.primuscable.com\/collections\/fiber-cleaning-wipes\" target=\"_blank\"\u003e\u003cstrong\u003ewipes.\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003ch4\u003eFeatures\u003c\/h4\u003e\n\u003ch3\u003e\u003cspan style=\"text-decoration: underline;\"\u003eFeatures\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eHigh performance components and construction\u003c\/li\u003e\n\u003cli\u003eHigh specific strength-to-weight ratio and compact cable design for limited conduit space and tight bends in long cable pulls\u003c\/li\u003e\n\u003cli\u003eHelically stranded core for flexibility, survival in difficult installations, and mechanical protection for the fibers\u003c\/li\u003e\n\u003cli\u003eLower installed cost\u003c\/li\u003e\n\u003cli\u003eHigh performance tight-buffered coating on each fiber for environmental and mechanical protection\u003c\/li\u003e\n\u003cli\u003eHigh crush resistance may eliminate the need for innerduct\u003c\/li\u003e\n\u003cli\u003e900 μm buffer eliminates the need for costly and time-consuming installation of fanout kits or pigtail splices because connectors terminate directly to the fiber.\u003c\/li\u003e\n\u003cli\u003eUL Listed in accordance with NEC section 770.179(a) for use in ducts, plenums and air-handling spaces\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eUsed in trunking, LAN and distribution applications where small size, lightweight, and versatile installation capability are required for ducts, plenums, and air handling spaces\u003c\/li\u003e\n\u003cli\u003eIdeal configuration for a single termination point requiring multiple fibers\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eIndoor\/Outdoor (\"K\" Jacket)\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eIndoor\/Outdoor plenum cables eliminate the need for costly cable transitions in different installation environments\u003c\/li\u003e\n\u003cli\u003eCable materials are UV, water and fungus resistant\u003c\/li\u003e\n\u003cli\u003eHigher fiber counts available than similar cables available by others in subgrouped configuration\u003c\/li\u003e\n\u003cli\u003eJacket is highly chemical resistant for installation in harsh industrial environments\u003c\/li\u003e\n\u003cli\u003eInterlocking armor can be applied to cables as an alternative to conduit installation\u003c\/li\u003e\n\u003cli\u003eCan be installed outside and in plenum or riser pathways inside, eliminating the need to transition cable types between environments\u003c\/li\u003e\n\u003cli\u003e2 to 72 fiber configuration is smaller and lighter than comparable sub-grouped cables, which is ideal for installation in areas with limited space or tight bends\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eStandards List\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eUL 1651\u003c\/li\u003e\n\u003cli\u003eANSI\/NFPA 262\u003c\/li\u003e\n\u003cli\u003eGR-409-CORE\u003c\/li\u003e\n\u003cli\u003eICEA-S-104-696\u003c\/li\u003e\n\u003cli\u003eICEA-S-83-596\u003c\/li\u003e\n\u003cli\u003eTIA-568\u003c\/li\u003e\n\u003cli\u003eTIA-598\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eSpec Sheet\u003c\/h4\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0079\/8874\/0186\/files\/OCC-DX-In-Out-Plenum.pdf?1491\" target=\"_blank\"\u003e \u003cbutton class=\"download-btn\"\u003eSpec Sheet\u003c\/button\u003e \u003c\/a\u003e\u003c\/p\u003e","brand":"OCC","offers":[{"title":"2 Strand","offer_id":31705670025277,"sku":"DX002KALE9QP","price":0.0,"currency_code":"USD","in_stock":true},{"title":"6 Strand","offer_id":31705670058045,"sku":"DX006KALE9QP","price":0.0,"currency_code":"USD","in_stock":true},{"title":"12 Strand","offer_id":31705670090813,"sku":"DX012KALE9QP","price":0.0,"currency_code":"USD","in_stock":true},{"title":"24 Strand","offer_id":31705670123581,"sku":"DX024KALE9QP","price":0.0,"currency_code":"USD","in_stock":true},{"title":"48 Strand","offer_id":31705670156349,"sku":"DX048KALE9QP","price":0.0,"currency_code":"USD","in_stock":true},{"title":"72 Strand","offer_id":31705670189117,"sku":"DX072KALE9QP","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0252\/1897\/3741\/products\/blue2_L_d52deb21-e0ac-4dc4-8a01-171dbfe4aa2d.jpg?v=1567190857"},{"product_id":"broadcast-fiber-optic-cable-single-mode-9125-outdoor-breakout-tactical-polyurethane","title":"Broadcast Fiber Optic Cable, Single Mode, 9\/125, Outdoor Breakout, Tactical Polyurethane","description":"\u003cp\u003e\u003cimg height=\"65px\" width=\"115px\" class=\"bulleticons\" alt=\"Made in USA\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0252\/1897\/3741\/files\/Made_In_USA.png?2208\"\u003e\u003c\/p\u003e\n\u003ch5\u003eWe do not offer credits or returns for this item.\u003c\/h5\u003e\n\u003cp\u003e\u003cstrong\u003eThis fiber cable is priced per foot and may include a minimum order length.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIf you would like to inquire about our custom fiber cable options such as terminated ends, pulleyes, and custom cut lengths, please call or email us.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003ci\u003ePlease call for shipping quote\u003c\/i\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch4\u003eDescription\u003c\/h4\u003e\n\u003ch2\u003eBroadcast Breakout Single Mode Fiber Optic Cable\u003c\/h2\u003e\n\u003cp\u003eThis Broadcast Breakout OS2 Single Mode 9\/125 Fiber Optic Cable can be used outdoors for temporary deployment directly on the ground in all terrains, including severe environments and has been tested to be used in broadcast data communications applications worldwide. The extremely strong, lightweight, rugged, survivable tight-buffered cables are designed for broadcast field use and commercial applications. The broadcast breakout cable design has individual color-coded subcables, allowing for easy identification of each optical fiber. Each breakout field broadcast cable is crush resistant and resilient, with two separate layers or aramid strength members in the subcables for individual single-fiber connector and termination pin, and overall for termination to multiway connector backshells or other housings.\u003c\/p\u003e\n\u003cp\u003eCleaning your fiber connector end faces and components regularly is crucial for avoiding a total network failure. Ensure your optical fiber system is working properly and prevent major network issues with \u003ca alt=\"Fiber Cleaning Kits\" href=\"https:\/\/www.primuscable.com\/collections\/fiber-cleaning-kit\" target=\"_blank\"\u003e\u003cstrong\u003e fiber cleaning kits,\u003c\/strong\u003e\u003c\/a\u003e \u003ca alt=\"Fiber Cleaning Pens\" href=\"https:\/\/www.primuscable.com\/collections\/fiber-cleaning-pens\" target=\"_blank\"\u003e\u003cstrong\u003e pens,\u003c\/strong\u003e\u003c\/a\u003e\u003ca alt=\"Fiber Cleaning Fluids\" href=\"https:\/\/www.primuscable.com\/collections\/fiber-cleaning-fluids\" target=\"_blank\"\u003e\u003cstrong\u003e fluids,\u003c\/strong\u003e\u003c\/a\u003e and \u003ca alt=\"Fiber Cleaning Wipes\" href=\"https:\/\/www.primuscable.com\/collections\/fiber-cleaning-wipes\" target=\"_blank\"\u003e\u003cstrong\u003ewipes.\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003ch4\u003eFeatures\u003c\/h4\u003e\n\u003ch3\u003e\u003cspan style=\"text-decoration: underline;\"\u003eFeatures\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eExtremely strong, lightweight, rugged, survivable tight-buffered cables designed for broadcast field use and commercial applications\u003c\/li\u003e\n\u003cli\u003ePolyurethane jacketed for abrasion, cut, and chemical resistance\u003c\/li\u003e\n\u003cli\u003eCore-locked jacket for improved mechanical performance\u003c\/li\u003e\n\u003cli\u003eBreakout cable design with individual color-coded subcables protecting each optical fiber\u003c\/li\u003e\n\u003cli\u003eCrush resistant and resilient, with two separate layers or aramid strength members in the subcables for individual single-fiber connector and termination pin, and overall for termination to multiway connector backshells or other housings\u003c\/li\u003e\n\u003cli\u003eHelically stranded cable core for flexibility, survival in difficult pulls, and excellent mechanical protection for the optical fibers\u003c\/li\u003e\n\u003cli\u003eCables have been tested and are in use in field broadcast data communications applications worldwide\u003c\/li\u003e\n\u003cli\u003eCan be used outdoors for temporary deployment directly on the ground, in all terrains,including severe environments\u003c\/li\u003e\n\u003cli\u003eSuitable for industrial, mining, and petrochemical environments; chemical resistant\u003c\/li\u003e\n\u003cli\u003eRound cable design for easy installation and survivability\u003c\/li\u003e\n\u003cli\u003eOften used with multiway military tactical connectors for maximum connector retention (400 lbs.)\u003c\/li\u003e\n\u003cli\u003eIdeally suited for use with MIL-C-38999 style military connectors; subcables terminate to individual pins, and overall aramid strength member terminates to backshell\u003c\/li\u003e\n\u003cli\u003e2.0mm subcables standard\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eDeployable cable that is ideal for harsh environments where deployment and retrieval for reuse are required for temporary broadcast networks\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eSpecifications\u003c\/h4\u003e\n\u003ch3\u003e\u003cbr\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0079\/8874\/0186\/files\/OCC_Breakout_SM_Specs.pdf?3926\" target=\"_blank\"\u003e \u003cbutton class=\"download-btn\"\u003eSpec Sheet\u003c\/button\u003e \u003c\/a\u003e \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0079\/8874\/0186\/files\/OCC-Ultra-Fox-perf_chart-1.pdf?1946\" target=\"_blank\"\u003e \u003cbutton class=\"download-btn\"\u003eFiber Performance Chart\u003c\/button\u003e \u003c\/a\u003e \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0079\/8874\/0186\/files\/OCC-Mil-Tac_Installation-General_Guidelines_Rev_B-1.pdf?3926\" target=\"_blank\"\u003e \u003cbutton class=\"download-btn\"\u003eGeneral Guidelines\u003c\/button\u003e \u003c\/a\u003e \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0079\/8874\/0186\/files\/OCC-Mil-Tac_Fiber_Optic_Field_Testing_Guidelines_Rev_A-1.pdf?3926\" target=\"_blank\"\u003e \u003cbutton class=\"download-btn\"\u003eTesting Guidelines\u003c\/button\u003e \u003c\/a\u003e \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0079\/8874\/0186\/files\/OCC-Mil-Tac_Storage_Handling_Rev_B-1.pdf?3926\" target=\"_blank\"\u003e \u003cbutton class=\"download-btn\"\u003eStorage Handling\u003c\/button\u003e \u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket Characteristics\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eOperating Temperature: -40ºC to +85ºC\u003c\/li\u003e\n\u003cli\u003eStorage Temperature: -70ºC to +85ºC\u003c\/li\u003e\n\u003cli\u003eCrush Resistance: 2,100 N\/cm\u003c\/li\u003e\n\u003cli\u003eImpact Resistance: 1,500 impacts\u003c\/li\u003e\n\u003cli\u003eFlex Resistance: 2,000 cycles\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"OCC","offers":[{"title":"2 Strand","offer_id":30010555138093,"sku":"BX002CSLX9KB","price":0.0,"currency_code":"USD","in_stock":true},{"title":"6 Strand","offer_id":31460206772285,"sku":"BX006CSLX9KB","price":0.0,"currency_code":"USD","in_stock":true},{"title":"12 Strand","offer_id":31460206968893,"sku":"BX012CSLX9KB","price":0.0,"currency_code":"USD","in_stock":true},{"title":"24 Strand","offer_id":31460207231037,"sku":"BX024CSLX9KB","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0252\/1897\/3741\/products\/Breakout-Black.png?v=1567190857"},{"product_id":"broadcast-fiber-optic-cable-multimode-62-5125-om1-outdoor-breakout-tactical-polyurethane","title":"Broadcast Breakout Fiber Optic Cable, Multimode, 62.5\/125 OM1, Outdoor, Tactical Polyurethane","description":"\u003cp\u003e\u003cimg height=\"65px\" width=\"115px\" class=\"bulleticons\" alt=\"Made in USA\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0252\/1897\/3741\/files\/Made_In_USA.png?2208\"\u003e\u003c\/p\u003e\n\u003ch5\u003eWe do not offer credits or returns for this item.\u003c\/h5\u003e\n\u003ch3\u003eThis fiber cable is priced per foot and may include a minimum order length.\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eIf you would like to inquire about our custom fiber cable options such as terminated ends, pulleyes, and custom cut lengths, please call or email us.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003ci\u003ePlease call for shipping quote\u003c\/i\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch4\u003eDescription\u003c\/h4\u003e\n\u003ch2\u003eBroadcast Breakout MultiMode OM1 Fiber Optic Cable\u003c\/h2\u003e\n\u003cp\u003eThis Broadcast Breakout OM1 MultiMode 62.5\/125 Fiber Optic Cable can be used outdoors for temporary deployment directly on the ground in all terrains, including severe environments and has been tested to be used in broadcast data communications applications worldwide. The extremely strong, lightweight, rugged, survivable tight-buffered cables are designed for broadcast field use and commercial applications. The broadcast breakout cable design has individual color-coded subcables, allowing for easy identification of each optical fiber. Each breakout field broadcast cable is crush resistant and resilient, with two separate layers or aramid strength members in the subcables for individual single-fiber connector and termination pin, and overall for termination to multiway connector backshells or other housings.\u003c\/p\u003e\n\u003cp\u003eCleaning your fiber connector end faces and components regularly is crucial for avoiding a total network failure. Ensure your optical fiber system is working properly and prevent major network issues with \u003ca alt=\"Fiber Cleaning Kits\" href=\"https:\/\/www.primuscable.com\/collections\/fiber-cleaning-kit\" target=\"_blank\"\u003e\u003cstrong\u003e fiber cleaning kits,\u003c\/strong\u003e\u003c\/a\u003e \u003ca alt=\"Fiber Cleaning Pens\" href=\"https:\/\/www.primuscable.com\/collections\/fiber-cleaning-pens\" target=\"_blank\"\u003e\u003cstrong\u003e pens,\u003c\/strong\u003e\u003c\/a\u003e\u003ca alt=\"Fiber Cleaning Fluids\" href=\"https:\/\/www.primuscable.com\/collections\/fiber-cleaning-fluids\" target=\"_blank\"\u003e\u003cstrong\u003e fluids,\u003c\/strong\u003e\u003c\/a\u003e and \u003ca alt=\"Fiber Cleaning Wipes\" href=\"https:\/\/www.primuscable.com\/collections\/fiber-cleaning-wipes\" target=\"_blank\"\u003e\u003cstrong\u003ewipes.\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003ch4\u003eFeatures\u003c\/h4\u003e\n\u003ch3\u003e\u003cspan style=\"text-decoration: underline;\"\u003eFeatures\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eExtremely strong, lightweight, rugged, survivable tight-buffered cables designed for broadcast field use and commercial applications\u003c\/li\u003e\n\u003cli\u003ePolyurethane jacketed for abrasion, cut, and chemical resistance\u003c\/li\u003e\n\u003cli\u003eCore-locked jacket for improved mechanical performance\u003c\/li\u003e\n\u003cli\u003eBreakout cable design with individual color-coded subcables protecting each optical fiber\u003c\/li\u003e\n\u003cli\u003eCrush resistant and resilient, with two separate layers or aramid strength members in the subcables for individual single-fiber connector and termination pin, and overall for termination to multiway connector backshells or other housings\u003c\/li\u003e\n\u003cli\u003eHelically stranded cable core for flexibility, survival in difficult pulls, and excellent mechanical protection for the optical fibers\u003c\/li\u003e\n\u003cli\u003eCables have been tested and are in use in field broadcast data communications applications worldwide\u003c\/li\u003e\n\u003cli\u003eCan be used outdoors for temporary deployment directly on the ground, in all terrains,including severe environments\u003c\/li\u003e\n\u003cli\u003eSuitable for industrial, mining, and petrochemical environments; chemical resistant\u003c\/li\u003e\n\u003cli\u003eRound cable design for easy installation and survivability\u003c\/li\u003e\n\u003cli\u003eOften used with multiway military tactical connectors for maximum connector retention (400 lbs.)\u003c\/li\u003e\n\u003cli\u003eIdeally suited for use with MIL-C-38999 style military connectors; subcables terminate to individual pins, and overall aramid strength member terminates to backshell\u003c\/li\u003e\n\u003cli\u003e2.0mm subcables standard\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDeployable cable that is ideal for harsh environments where deployment and retrieval for reuse are required for temporary broadcast networks\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eSpecifications\u003c\/h4\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0079\/8874\/0186\/files\/OCC_Breakout_SM_Specs.pdf?3926\" target=\"_blank\"\u003e \u003cbutton class=\"download-btn\"\u003eSpec Sheet\u003c\/button\u003e \u003c\/a\u003e \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0079\/8874\/0186\/files\/OCC-Ultra-Fox-perf_chart-1.pdf?1946\" target=\"_blank\"\u003e \u003cbutton class=\"download-btn\"\u003eFiber Performance Chart\u003c\/button\u003e \u003c\/a\u003e \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0079\/8874\/0186\/files\/OCC-Mil-Tac_Installation-General_Guidelines_Rev_B-1.pdf?3926\" target=\"_blank\"\u003e \u003cbutton class=\"download-btn\"\u003eGeneral Guidelines\u003c\/button\u003e \u003c\/a\u003e \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0079\/8874\/0186\/files\/OCC-Mil-Tac_Fiber_Optic_Field_Testing_Guidelines_Rev_A-1.pdf?3926\" target=\"_blank\"\u003e \u003cbutton class=\"download-btn\"\u003eTesting Guidelines\u003c\/button\u003e \u003c\/a\u003e \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0079\/8874\/0186\/files\/OCC-Mil-Tac_Storage_Handling_Rev_B-1.pdf?3926\" target=\"_blank\"\u003e \u003cbutton class=\"download-btn\"\u003eStorage Handling\u003c\/button\u003e \u003c\/a\u003e\u003c\/p\u003e\n\u003ch3\u003eJacket Characteristics\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eOperating Temperature: -40ºC to +85ºC\u003c\/li\u003e\n\u003cli\u003eStorage Temperature: -70ºC to +85ºC\u003c\/li\u003e\n\u003cli\u003eCrush Resistance: 2,100 N\/cm\u003c\/li\u003e\n\u003cli\u003eImpact Resistance: 1,500 impacts\u003c\/li\u003e\n\u003cli\u003eFlex Resistance: 2,000 cycles\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"OCC","offers":[{"title":"2 Strand","offer_id":30010555039789,"sku":"BX002CWLS9KB","price":0.0,"currency_code":"USD","in_stock":true},{"title":"6 Strand","offer_id":31460219682877,"sku":"BX006CWLS9KB","price":0.0,"currency_code":"USD","in_stock":true},{"title":"12 Strand","offer_id":31460220272701,"sku":"BX012CWLS9KB","price":0.0,"currency_code":"USD","in_stock":true},{"title":"24 Strand","offer_id":31460220796989,"sku":"BX024CWLS9KB","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0252\/1897\/3741\/products\/Breakout-Black_6b171475-968a-4a00-8937-80f37dbe4ae9.png?v=1567190857"},{"product_id":"breakout-fiber-optic-cable-multimode-50125-10-gig-om4-indooroutdoor-plenum","title":"Breakout Plenum Fiber Optic Cable, Multimode 10 Gig OM4, Indoor\/Outdoor","description":"\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0252\/1897\/3741\/files\/Made_In_USA.png?2208\" alt=\"Made in USA\" width=\"115px\" height=\"65px\" style=\"background-color: #fff; border-radius: 10px; padding: 5px;\"\u003e \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0252\/1897\/3741\/files\/UL_LISTED_LOGO_US.png?2209\" alt=\"UL Listed\" width=\"75px\" height=\"65px\" style=\"background-color: #fff; border-radius: 10px; padding: 5px;\"\u003e \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0252\/1897\/3741\/files\/Bullets-_RoHS.jpg?2209\" alt=\"RoHS Compliant\" width=\"55px\" height=\"75px\" style=\"background-color: #fff; border-radius: 10px; padding: 5px;\"\u003e \u003cmeta charset=\"utf-8\"\u003e\u003c\/p\u003e\n\u003ch5\u003e(We do not offer credits or returns for this item.)\u003c\/h5\u003e\n\u003cp\u003e\u003cstrong\u003eThis fiber cable is priced per foot and may include a minimum order length.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIf you would like to inquire about our custom fiber cable options such as terminated ends, pulleyes, and custom cut lengths, please call or email us.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003ci\u003ePlease call for shipping quote\u003c\/i\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch4\u003eDescription\u003c\/h4\u003e\n\u003ch2\u003eBreakout Fiber Optic Cable, Multimode, 50\/125 10 Gig OM4, Indoor\/Outdoor, Plenum\u003c\/h2\u003e\n\u003cp\u003eThis Breakout Plenum OFNP MultiMode 50\/125 OM4 Fiber Cable is ideal for installations requiring an extremely rugged and reliable fiber optic cable design where maximum mechanical and environmental protection are necessary. It's the easiest fiber cable to install where direct termination of connectors to sub-units and direct run to panels and equipment is desired. Direct termination of the plenum breakout fiber cable to each subcable provides additional strain relief for better connector retention during moves, adds, and changes. Breakout plenum fiber cables utilize high performance components and construction and are UL Listed in accordance with NEC sections 770.179(b) for use in ducts, plenums and air-handling spaces.\u003c\/p\u003e\n\u003cp\u003eCleaning your fiber connector end faces and components regularly is crucial for avoiding a total network failure. Ensure your optical fiber system is working properly and prevent major network issues with \u003ca href=\"https:\/\/www.primuscable.com\/collections\/fiber-cleaning-kit\" alt=\"Fiber Cleaning Kits\" target=\"_blank\"\u003e\u003cstrong\u003e \u003c\/strong\u003efiber cleaning kits,\u003c\/a\u003e \u003ca href=\"https:\/\/www.primuscable.com\/collections\/fiber-cleaning-pens\" alt=\"Fiber Cleaning Pens\" target=\"_blank\"\u003e pens,\u003c\/a\u003e\u003ca href=\"https:\/\/www.primuscable.com\/collections\/fiber-cleaning-fluids\" alt=\"Fiber Cleaning Fluids\" target=\"_blank\"\u003e fluids,\u003c\/a\u003e and \u003ca href=\"https:\/\/www.primuscable.com\/collections\/fiber-cleaning-wipes\" alt=\"Fiber Cleaning Wipes\" target=\"_blank\"\u003ewipes.\u003c\/a\u003e\u003c\/p\u003e\n\u003ch4\u003eFeatures\u003c\/h4\u003e\n\u003ch3\u003e\u003cspan style=\"text-decoration: underline;\"\u003eFeatures\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eHigh performance components and construction\u003c\/li\u003e\n\u003cli\u003eUL Listed in accordance with NEC sections 770.179(b) for use in ducts, plenums and air-handling spaces\u003c\/li\u003e\n\u003cli\u003eMost rugged and easy to install cable design for enterprise cabling applications\u003c\/li\u003e\n\u003cli\u003eCore-Locked™ outer jacket design for installation survivability, long-term, trouble free service\u003c\/li\u003e\n\u003cli\u003eIdeal for use in long, vertical installations\u003c\/li\u003e\n\u003cli\u003e2.0mm subcables can be direct-terminated with standard connectors (2.5mm and 2.9mm subcables also available)\u003c\/li\u003e\n\u003cli\u003eSubcabled fiber is environmentally and mechanically protected\u003c\/li\u003e\n\u003cli\u003eIdeal for use in point-to-point runs in adverse environments\u003c\/li\u003e\n\u003cli\u003eDirect termination to subcable provides additional strain relief for better connector retention during moves, adds, and changes\u003c\/li\u003e\n\u003cli\u003eDesign is ideal for direct pulling with mesh grips\u003c\/li\u003e\n\u003cli\u003eCable materials are indoor\/outdoor - UV, water and fungus resistant\u003c\/li\u003e\n\u003cli\u003eWide operating temperature range of -40ºC to +85ºC\u003c\/li\u003e\n\u003cli\u003eHigh performance 900 um tight buffered coating on each optical fiber for environmental and mechanical protection\u003c\/li\u003e\n\u003cli\u003eInterlocking armor can be applied to cables as an alternative to conduit installation\u003c\/li\u003e\n\u003cli\u003e2 to 48 fibers\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eIdeal for installations requiring an extremely rugged and reliable cable design where maximum mechanical and environmental protection are necessary\u003c\/li\u003e\n\u003cli\u003eEasiest cable to install where direct termination of connectors to sub-units and direct run to panels and equipment is desired\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eCost Savings\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eDirect termination to subcable may eliminate the need for patch panels and patch cords and reduces connector loss\u003c\/li\u003e\n\u003cli\u003e900 um buffer eliminates the need for costly and time-consuming installation of fanout kits or pigtail splices because connectors terminate directly to the fiber\u003c\/li\u003e\n\u003cli\u003eHigh crush resistance may eliminate the need for innerduct\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eSpecifications\u003c\/h4\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0079\/8874\/0186\/files\/OCC_Breakout_OFNP_Specs.pdf?3934\" target=\"_blank\"\u003e \u003cbutton class=\"download-btn\"\u003eSpec Sheet\u003c\/button\u003e \u003c\/a\u003e \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0079\/8874\/0186\/files\/OCC-Ultra-Fox-perf_chart-1.pdf?1946\" target=\"_blank\"\u003e \u003cbutton class=\"download-btn\"\u003eFiber Performance Chart\u003c\/button\u003e \u003c\/a\u003e \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0079\/8874\/0186\/files\/OCC-Mil-Tac_Installation-General_Guidelines_Rev_B-1.pdf?3926\" target=\"_blank\"\u003e \u003cbutton class=\"download-btn\"\u003eGeneral Guidelines\u003c\/button\u003e \u003c\/a\u003e \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0079\/8874\/0186\/files\/OCC-Mil-Tac_Fiber_Optic_Field_Testing_Guidelines_Rev_A-1.pdf?3926\" target=\"_blank\"\u003e \u003cbutton class=\"download-btn\"\u003eTesting Guidelines\u003c\/button\u003e \u003c\/a\u003e \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0079\/8874\/0186\/files\/OCC-Mil-Tac_Storage_Handling_Rev_B-1.pdf?3926\" target=\"_blank\"\u003e \u003cbutton class=\"download-btn\"\u003eStorage Handling\u003c\/button\u003e \u003c\/a\u003e \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0079\/8874\/0186\/files\/OCC_Recommended_Duct_Installation_Guideline_Rev_2-1.pdf?3933\" target=\"_blank\"\u003e \u003cbutton class=\"download-btn\"\u003eDuct Install Guidelines\u003c\/button\u003e \u003c\/a\u003e \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0079\/8874\/0186\/files\/OCC_Installation-Cable_Tray_Vertical_Rise_Guidelines_Rev_A-1.pdf?3933\" target=\"_blank\"\u003e \u003cbutton class=\"download-btn\"\u003eCable Tray Guidelines\u003c\/button\u003e \u003c\/a\u003e \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0079\/8874\/0186\/files\/OCC_Breakout_and_Subgrouping_Cable_Pulling_Grip_Installation_Procedure_Rev._1-1.pdf?3933\" target=\"_blank\"\u003e \u003cbutton class=\"download-btn\"\u003eCable Pulling Installation\u003c\/button\u003e \u003c\/a\u003e\u003c\/p\u003e\n\u003ctable width=\"100%\" class=\"table table-bordered text-center\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth colspan=\"2\"\u003eTECHNICAL SPECIFICATIONS\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003c!-- JACKET CHARACTERISTICS --\u003e\n\u003ctr\u003e\n\u003cth class=\"table-active\" colspan=\"2\"\u003eJACKET CHARACTERISTICS\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth class=\"table-active\" scope=\"row\"\u003eOPERATING TEMPERATURE\u003c\/th\u003e\n\u003ctd\u003e-40ºC TO +85ºC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth class=\"table-active\" scope=\"row\"\u003eSTORAGE TEMPERATURE\u003c\/th\u003e\n\u003ctd\u003e-40ºC TO +85ºC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth class=\"table-active\" scope=\"row\"\u003eINSTALLATION TEMPERATURE\u003c\/th\u003e\n\u003ctd\u003e0ºC TO +60ºC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth class=\"table-active\" scope=\"row\"\u003eFLAME RETARDANCY\u003c\/th\u003e\n\u003ctd\u003eUL LISTED TYPE OFNP (ANSI\/NFPA 262) AND FT6 (CSA C22.2 NO. 232)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth class=\"table-active\" scope=\"row\"\u003eCRUSH RESISTANCE\u003c\/th\u003e\n\u003ctd\u003e2,100 N\/CM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth class=\"table-active\" scope=\"row\"\u003eIMPACT RESISTANCE\u003c\/th\u003e\n\u003ctd\u003e1,000 IMPACTS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth class=\"table-active\" scope=\"row\"\u003eFLEX RESISTANCE\u003c\/th\u003e\n\u003ctd\u003e2,000 CYCLES\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c!-- STANDARDS LIST --\u003e\n\u003ctr\u003e\n\u003cth class=\"table-active\" colspan=\"2\"\u003eSTANDARDS LIST\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eUL 1651; ANSI\/NFPA 262; GR-409-CORE; ICEA-S-104-696; ICEA-S-83-596; TIA-568; TIA-598\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4\u003eWhat's in the Box\u003c\/h4\u003e\n\u003ch3\u003e\n\u003cspan style=\"text-decoration: underline;\"\u003eWhat’s in the Box\u003c\/span\u003e\u003cbr\u003e\n\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eQty 1 - Breakout Plenum Fiber Optic Cable, Multimode 10 Gig OM4, Indoor\/Outdoor\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"OCC","offers":[{"title":"2 Strand","offer_id":30010554286125,"sku":"BX002KALE9QP","price":0.0,"currency_code":"USD","in_stock":true},{"title":"4 Strand","offer_id":31461380030525,"sku":"BX004KALE9QP","price":0.0,"currency_code":"USD","in_stock":true},{"title":"6 Strand","offer_id":31461381013565,"sku":"BX006KALE9QP","price":0.0,"currency_code":"USD","in_stock":true},{"title":"8 Strand","offer_id":31461381603389,"sku":"BX008KALE9QP","price":0.0,"currency_code":"USD","in_stock":true},{"title":"12 Strand","offer_id":31461397037117,"sku":"BX012KALE9QP","price":0.0,"currency_code":"USD","in_stock":true},{"title":"18 Strand","offer_id":31461397659709,"sku":"BX018KALE9QP","price":0.0,"currency_code":"USD","in_stock":true},{"title":"24 Strand","offer_id":31461398577213,"sku":"BX024KALE9QP","price":0.0,"currency_code":"USD","in_stock":true},{"title":"36 Strand","offer_id":31461399134269,"sku":"BX036KALE9QP","price":0.0,"currency_code":"USD","in_stock":true},{"title":"48 Strand","offer_id":31461399593021,"sku":"BX048KALE9QP","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0252\/1897\/3741\/products\/Breakout-10G_1f847c89-d049-4c9a-99f9-9468cf27d8d5.png?v=1567190967"},{"product_id":"breakout-fiber-optic-cable-multimode-50125-10-gig-om4-indooroutdoor-riser","title":"Indoor\/Outdoor Breakout Riser Multimode 10 Gig OM4 Fiber Optic Cable","description":"\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0252\/1897\/3741\/files\/Made_In_USA.png?2208\" alt=\"Made in USA\" width=\"115px\" height=\"65px\" style=\"background-color: #fff; border-radius: 10px; padding: 5px;\"\u003e \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0252\/1897\/3741\/files\/UL_LISTED_LOGO_US.png?2209\" alt=\"UL Listed\" width=\"75px\" height=\"65px\" style=\"background-color: #fff; border-radius: 10px; padding: 5px;\"\u003e \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0252\/1897\/3741\/files\/Bullets-_RoHS.jpg?2209\" alt=\"RoHS Compliant\" width=\"55px\" height=\"75px\" style=\"background-color: #fff; border-radius: 10px; padding: 5px;\"\u003e \u003cmeta charset=\"utf-8\"\u003e\u003c\/p\u003e\n\u003ch5\u003e(We do not offer credits or returns for this item.)\u003c\/h5\u003e\n\u003cp\u003e\u003cstrong\u003eThis fiber cable is priced per foot and may include a minimum order length.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIf you would like to inquire about our custom fiber cable options such as terminated ends, pulleyes, and custom cut lengths, please call or email us.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003ci\u003ePlease call for shipping quote\u003c\/i\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch4\u003eDescription\u003c\/h4\u003e\n\u003ch2\u003e\n\u003cmeta charset=\"utf-8\"\u003e \u003cspan\u003eIndoor\/Outdoor Riser Breakout Multimode 50\/125 10 Gig OM4 Fiber Optic Cable\u003c\/span\u003e\n\u003c\/h2\u003e\n\u003cp\u003e\u003cmeta charset=\"utf-8\"\u003e\u003cspan\u003eThis Breakout Riser OFNR MultiMode 50\/125 OM4 Fiber Cable is designed for installations requiring robust and reliable fiber optic setups with maximum mechanical and environmental protection. It simplifies connector termination for sub-units and panels, providing additional strain relief to enhance connector retention during adjustments. These cables feature high-performance components and construction, and are UL Listed for vertical riser shaft runs as per NEC sections 770.179(b)\u003c\/span\u003e.\u003c\/p\u003e\n\u003cp\u003eCleaning your fiber connector end faces and components regularly is crucial for avoiding a total network failure. Ensure your optical fiber system is working properly and prevent major network issues with \u003ca href=\"https:\/\/www.primuscable.com\/collections\/fiber-cleaning-kit\" alt=\"Fiber Cleaning Kits\" target=\"_blank\"\u003e\u003cstrong\u003e \u003c\/strong\u003efiber cleaning kits,\u003c\/a\u003e \u003ca href=\"https:\/\/www.primuscable.com\/collections\/fiber-cleaning-pens\" alt=\"Fiber Cleaning Pens\" target=\"_blank\"\u003e pens,\u003c\/a\u003e\u003ca href=\"https:\/\/www.primuscable.com\/collections\/fiber-cleaning-fluids\" alt=\"Fiber Cleaning Fluids\" target=\"_blank\"\u003e fluids,\u003c\/a\u003e and \u003ca href=\"https:\/\/www.primuscable.com\/collections\/fiber-cleaning-wipes\" alt=\"Fiber Cleaning Wipes\" target=\"_blank\"\u003ewipes.\u003c\/a\u003e\u003c\/p\u003e\n\u003ch4\u003eFeatures\u003c\/h4\u003e\n\u003ch3\u003e\u003cspan style=\"text-decoration: underline;\"\u003eFeatures\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eHigh performance components and construction\u003c\/li\u003e\n\u003cli\u003eUL Listed in accordance with NEC sections 770.179(b) for use in vertical runs in building riser shafts or from floor to floor\u003c\/li\u003e\n\u003cli\u003eMost rugged and easy to install cable design for enterprise cabling applications\u003c\/li\u003e\n\u003cli\u003eCore-Locked™ outer jacket design for installation survivability, long-term, trouble free service\u003c\/li\u003e\n\u003cli\u003eIdeal for use in long, vertical installations\u003c\/li\u003e\n\u003cli\u003e2.5mm subcables can be direct-terminated with standard connectors (2.0mm and 2.9mm subcables also available)\u003c\/li\u003e\n\u003cli\u003eSubcabled fiber is environmentally and mechanically protected\u003c\/li\u003e\n\u003cli\u003eIdeal for use in point-to-point runs in adverse environments\u003c\/li\u003e\n\u003cli\u003eDirect termination to subcable provides additional strain relief for better connector retention during moves, adds, and changes\u003c\/li\u003e\n\u003cli\u003eDesign is ideal for direct pulling with mesh grips\u003c\/li\u003e\n\u003cli\u003eCable materials are indoor\/outdoor - UV, water and fungus resistant\u003c\/li\u003e\n\u003cli\u003eWide operating temperature range of -40ºC to +85ºC\u003c\/li\u003e\n\u003cli\u003eHigh performance 900 _m tight buffered coating on each optical fiber for environmental and mechanical protection\u003c\/li\u003e\n\u003cli\u003eInterlocking armor can be applied to cables as an alternative to conduit installation\u003c\/li\u003e\n\u003cli\u003e2 to 72 fibers\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eIdeal for installations requiring an extremely rugged and reliable cable design where maximum mechanical and environmental protection are necessary\u003c\/li\u003e\n\u003cli\u003eEasiest cable to install where direct termination of connectors to sub-units and direct run to panels and equipment is desired\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eCost Savings\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eDirect termination to subcable may eliminate the need for patch panels and patch cords and reduces connector loss\u003c\/li\u003e\n\u003cli\u003e900 _m buffer eliminates the need for costly and time-consuming installation of fanout kits or pigtail splices because connectors terminate directly to the fiber\u003c\/li\u003e\n\u003cli\u003eHigh crush resistance may eliminate the need for innerduct\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eStandards List\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eUL 1651\u003c\/li\u003e\n\u003cli\u003eUL 1666\u003c\/li\u003e\n\u003cli\u003eGR-409-CORE\u003c\/li\u003e\n\u003cli\u003eICEA-S-104-696\u003c\/li\u003e\n\u003cli\u003eICEA-S-83-596\u003c\/li\u003e\n\u003cli\u003eTIA-568\u003c\/li\u003e\n\u003cli\u003eTIA-598\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eSpecifications\u003c\/h4\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0079\/8874\/0186\/files\/OCC_Breakout_OFNP_Specs.pdf?3934\" target=\"_blank\"\u003e \u003cbutton class=\"download-btn\"\u003eSpec Sheet\u003c\/button\u003e \u003c\/a\u003e \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0079\/8874\/0186\/files\/OCC-Ultra-Fox-perf_chart-1.pdf?1946\" target=\"_blank\"\u003e \u003cbutton class=\"download-btn\"\u003eFiber Performance Chart\u003c\/button\u003e \u003c\/a\u003e \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0079\/8874\/0186\/files\/OCC-Mil-Tac_Installation-General_Guidelines_Rev_B-1.pdf?3926\" target=\"_blank\"\u003e \u003cbutton class=\"download-btn\"\u003eGeneral Guidelines\u003c\/button\u003e \u003c\/a\u003e \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0079\/8874\/0186\/files\/OCC-Mil-Tac_Fiber_Optic_Field_Testing_Guidelines_Rev_A-1.pdf?3926\" target=\"_blank\"\u003e \u003cbutton class=\"download-btn\"\u003eTesting Guidelines\u003c\/button\u003e \u003c\/a\u003e \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0079\/8874\/0186\/files\/OCC-Mil-Tac_Storage_Handling_Rev_B-1.pdf?3926\" target=\"_blank\"\u003e \u003cbutton class=\"download-btn\"\u003eStorage Handling\u003c\/button\u003e \u003c\/a\u003e\u003c\/p\u003e\n\u003ctable width=\"100%\" class=\"table table-bordered text-center\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth colspan=\"2\"\u003eTECHNICAL SPECIFICATIONS\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003c!-- JACKET CHARACTERISTICS --\u003e\n\u003ctr\u003e\n\u003cth class=\"table-active\" colspan=\"2\"\u003eJACKET CHARACTERISTICS\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth class=\"table-active\" scope=\"row\"\u003eOPERATING TEMPERATURE\u003c\/th\u003e\n\u003ctd\u003e-50ºC TO +75ºC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth class=\"table-active\" scope=\"row\"\u003eSTORAGE TEMPERATURE\u003c\/th\u003e\n\u003ctd\u003e-55ºC TO +85ºC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth class=\"table-active\" scope=\"row\"\u003eINSTALLATION TEMPERATURE\u003c\/th\u003e\n\u003ctd\u003e-30ºC TO +60ºC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth class=\"table-active\" scope=\"row\"\u003eFLAME RETARDANCY\u003c\/th\u003e\n\u003ctd\u003e\u0026gt;UL LISTED TYPE OFNR (UL 1666) AND FT4 (CSA C22.2 NO. 232)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth class=\"table-active\" scope=\"row\"\u003eCRUSH RESISTANCE\u003c\/th\u003e\n\u003ctd\u003e2,200 N\/CM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth class=\"table-active\" scope=\"row\"\u003eIMPACT RESISTANCE\u003c\/th\u003e\n\u003ctd\u003e1,500 IMPACTS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth class=\"table-active\" scope=\"row\"\u003eFLEX RESISTANCE\u003c\/th\u003e\n\u003ctd\u003e2,000 CYCLES\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4\u003eWhat's in the Box\u003c\/h4\u003e\n\u003ch3\u003e\u003cspan style=\"text-decoration: underline;\"\u003eWhat’s in the Box\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eQty 1 - Indoor\/Outdoor Breakout Riser Multimode 10 Gig OM4 Fiber Optic Cable\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"OCC","offers":[{"title":"2 Strand","offer_id":30010554712109,"sku":"BX002DALE9QR","price":0.0,"currency_code":"USD","in_stock":true},{"title":"4 Strand","offer_id":31460859445309,"sku":"BX004DALE9QR","price":0.0,"currency_code":"USD","in_stock":true},{"title":"6 Strand","offer_id":31460860821565,"sku":"BX006DALE9QR","price":0.0,"currency_code":"USD","in_stock":true},{"title":"8 Strand","offer_id":31460861870141,"sku":"BX008DALE9QR","price":0.0,"currency_code":"USD","in_stock":true},{"title":"12 Strand","offer_id":31460862918717,"sku":"BX012DALE9QR","price":0.0,"currency_code":"USD","in_stock":true},{"title":"18 Strand","offer_id":31460863836221,"sku":"BX018DALE9QR","price":0.0,"currency_code":"USD","in_stock":true},{"title":"24 Strand","offer_id":31460864819261,"sku":"BX024DALE9QR","price":0.0,"currency_code":"USD","in_stock":true},{"title":"36 Strand","offer_id":31460865638461,"sku":"BX036DALE9QR","price":0.0,"currency_code":"USD","in_stock":true},{"title":"48 Strand","offer_id":31460866129981,"sku":"BX048DALE9QR","price":0.0,"currency_code":"USD","in_stock":true},{"title":"60 Strand","offer_id":31460867833917,"sku":"BX060DALE9QR","price":0.0,"currency_code":"USD","in_stock":true},{"title":"72 Strand","offer_id":31460868259901,"sku":"BX072DALE9QR","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0252\/1897\/3741\/products\/Breakout-IO_515x422_3880cff7-0a31-402a-a44d-fbf21cefd762.png?v=1576624502"},{"product_id":"distribution-fiber-optic-cable-2-strand-multimode-50125-10-gig-om4-indooroutdoor-riser","title":"Tight Buffer Distribution Riser Fiber Optic Cable: OM4 Multimode 10 Gig for Indoor\/Outdoor Use","description":"\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0252\/1897\/3741\/files\/Made_In_USA.png?2208\" alt=\"Made in USA\" class=\"bulleticons\" width=\"115px\" height=\"65px\"\u003e \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0252\/1897\/3741\/files\/UL_LISTED_LOGO_US.png?2209\" alt=\"UL Listed\" class=\"bulleticons\" width=\"76px\" height=\"65px\"\u003e\u003c\/p\u003e\n\u003ch3\u003eWe do not offer credits or returns for this item.\u003c\/h3\u003e\n\u003ch3\u003eThis fiber cable is priced per foot and may include a minimum order length.\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eIf you would like to inquire about our custom fiber cable options such as terminated ends, pulleyes, and custom cut lengths, please call or email us.\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch4\u003eDescription\u003c\/h4\u003e\n\u003ch2\u003eBulk Fiber, Multi-Mode, OM4 50\/125, Distribution Cable, OFNR Riser Rated, Indoor\/Outdoor, Tight Buffer, Black Outer Jacket\u003c\/h2\u003e\n\u003cp\u003e\u003cmeta charset=\"utf-8\"\u003e\u003cspan\u003eThis indoor\/outdoor riser distribution fiber cable is perfect for various applications. Its tight-bound, tight-buffered design enables seamless installation in both intra-building backbone and inter-building campus setups without expensive transitions between cable types. It's particularly suited for setups needing a single termination point with multiple fibers. Engineered with high-performance components and construction, this riser distribution fiber cable is UL Listed according to NEC sections 770.179(b), making it suitable for vertical runs in building riser shafts or between floors.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eMulti-Mode Fiber Information\u003c\/h3\u003e\n\u003cp\u003eMulti-Mode cable commonly has a diameter in the 50-to-100 micron range (typical multimode fiber core diameters are 50 or 62.5 micrometers). Multimode fiber gives you high bandwidth at high speeds (10 to 100MBS - Gigabit to 275m to 2km) over medium distances. Light waves are dispersed into numerous paths, or modes, as they travel through the cable's core typically 850 or 1300nm. However, in long cable runs (greater than 3000 feet [914.4 meters), multiple paths of light can cause signal distortion at the receiving end, resulting in an unclear and incomplete data transmission so designers now call for single mode fiber in new applications using Gigabit and beyond.\u003c\/p\u003e\n\u003ch3\u003eApplications:\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eIndoor\/outdoor tight-bound tight-buffered design allows cables to be installed in intra-building backbone and inter-building campus locations without costly transitions between cable types\u003c\/li\u003e\n\u003cli\u003eIdeal configuration for a single termination point requiring multiple fibers\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCost Savings\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e900 micron buffer eliminates the need for costly and time-consuming installation of fanout kits or pigtail splices because connectors terminate directly to the fiber\u003c\/li\u003e\n\u003cli\u003eNo need to splice outdoor cable to indoor cable at building entrance\u003c\/li\u003e\n\u003cli\u003eHigh crush resistance may eliminate the need for innerduct\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan\u003eCleaning your fiber connector end faces and components regularly is crucial for avoiding a total network failure. Ensure your optical fiber system is working properly and prevent major network issues with \u003c\/span\u003e\u003ca href=\"https:\/\/www.primuscable.com\/collections\/fiber-cleaning-kit\" alt=\"Fiber Cleaning Kits\" target=\"_blank\"\u003efiber cleaning kits,\u003c\/a\u003e \u003ca href=\"https:\/\/www.primuscable.com\/collections\/fiber-cleaning-pens\" alt=\"Fiber Cleaning Pens\" target=\"_blank\"\u003epens,\u003c\/a\u003e\u003ca href=\"https:\/\/www.primuscable.com\/collections\/fiber-cleaning-fluids\" alt=\"Fiber Cleaning Fluids\" target=\"_blank\"\u003e fluids,\u003c\/a\u003e and \u003ca href=\"https:\/\/www.primuscable.com\/collections\/fiber-cleaning-wipes\" alt=\"Fiber Cleaning Wipes\" target=\"_blank\"\u003ewipes.\u003c\/a\u003e\u003c\/p\u003e\n\u003ch4\u003eFeatures\u003c\/h4\u003e\n\u003ch3\u003e\u003cspan style=\"text-decoration: underline;\"\u003eFeatures\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eHigh performance components and construction\u003c\/li\u003e\n\u003cli\u003eCable materials are indoor\/outdoor - UL-listed OFNR and UV, water and fungus resistant\u003c\/li\u003e\n\u003cli\u003eUL Listed in accordance with NEC section 770.179(b) for use in vertical runs in building riser shafts or from floor to floor\u003c\/li\u003e\n\u003cli\u003eWide operating temperature range of -40ºC to +85ºC\u003c\/li\u003e\n\u003cli\u003eHelically stranded core for greater flexibility and mechanical protection of the optical fibers\u003c\/li\u003e\n\u003cli\u003eHigh strength-to-weight ratio\u003c\/li\u003e\n\u003cli\u003e2-144 fiber configuration is smaller and lighter than comparable sub-grouped cables made by others: ideal for installation in areas with limited space or tight bends\u003c\/li\u003e\n\u003cli\u003eCan be armored for additional protection in direct burial and aerial installations\u003c\/li\u003e\n\u003cli\u003eInterlocking armor can be applied to cables as an alternative to conduit installation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eSpecifications\u003c\/h4\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0079\/8874\/0186\/files\/OCC-DX-Riser-Specs.pdf?1515\" target=\"_blank\"\u003e \u003cbutton class=\"download-btn\"\u003eSpec Sheet\u003c\/button\u003e \u003c\/a\u003e \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0079\/8874\/0186\/files\/OCC-Ultra-Fox-perf_chart-1.pdf?1510\" target=\"_blank\"\u003e \u003cbutton class=\"download-btn\"\u003eFiber Performance Chart\u003c\/button\u003e \u003c\/a\u003e\u003c\/p\u003e\n\u003ctable width=\"100%\" class=\"table table-bordered text-center\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth class=\"table-dark\" colspan=\"2\"\u003eTECHNICAL SPECIFICATIONS\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: center;\" colspan=\"2\"\u003eCHARACTERISTICS\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth class=\"table-active\" scope=\"row\"\u003eOperating Temp\u003c\/th\u003e\n\u003ctd\u003e-40°C to +85°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth class=\"table-active\" scope=\"row\"\u003eStorage Temp\u003c\/th\u003e\n\u003ctd\u003e-55°C to +85°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth class=\"table-active\" scope=\"row\"\u003eInstall Temp\u003c\/th\u003e\n\u003ctd\u003e-10°C to +60°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth class=\"table-active\" scope=\"row\"\u003eFlame Retardancy\u003c\/th\u003e\n\u003ctd\u003eUL Listed Type OFNR (UL 1666)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth class=\"table-active\" scope=\"row\"\u003eCrush Resist\u003c\/th\u003e\n\u003ctd\u003e1800 N\/cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth class=\"table-active\" scope=\"row\"\u003eImpact Resist\u003c\/th\u003e\n\u003ctd\u003e1500 impacts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth class=\"table-active\" scope=\"row\"\u003eFlex Resist\u003c\/th\u003e\n\u003ctd\u003e2000 cycles\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth class=\"table-active\" scope=\"row\"\u003eJacket Type\u003c\/th\u003e\n\u003ctd\u003eD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: center;\" colspan=\"2\"\u003eSTANDARDS\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"p-3\" colspan=\"2\"\u003eOptical Cable Corporation's Indoor\/Outdoor tight-buffered fiber optic cables meet the functional requirements of the following standards:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth class=\"table-active\" scope=\"row\"\u003eIndustry Standards\u003c\/th\u003e\n\u003ctd\u003eUL 1651, UL 1666, GR-409-CORE, ICEA-S-104-696, ICEA-S-83-596, TIA-568, TIA-598\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth class=\"table-active\" scope=\"row\"\u003eCompliance\u003c\/th\u003e\n\u003ctd\u003eUL-listed type OFNR in accordance with NEC sections 770-179 (B) and 770-154 (B). Meets or exceeds requirements for intra-building fiber optic cables as outlined in GR-409-CORE.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eWhat's in the Box\u003c\/h4\u003e\n\u003ch3\u003e\u003cspan style=\"text-decoration: underline;\"\u003eWhat’s in the Box\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eQty 1 - Tight Buffer Distribution Riser Fiber Optic Cable: OM4 Multimode 10 Gig for Indoor\/Outdoor Use\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"OCC","offers":[{"title":"2 Stand","offer_id":31705564151869,"sku":"DX002DALE9QR","price":0.0,"currency_code":"USD","in_stock":true},{"title":"6 Strand","offer_id":31705564184637,"sku":"DX006DALE9QR","price":0.99,"currency_code":"USD","in_stock":true},{"title":"12 Strand","offer_id":31705564217405,"sku":"DX012DALE9QR","price":1.67,"currency_code":"USD","in_stock":true},{"title":"24 Strand","offer_id":31705564250173,"sku":"DX024DALE9QR","price":0.0,"currency_code":"USD","in_stock":true},{"title":"48 Strand","offer_id":31705564315709,"sku":"DX048DALE9QR","price":0.0,"currency_code":"USD","in_stock":true},{"title":"72 Strand","offer_id":31705564381245,"sku":"DX072DALE9QR","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0252\/1897\/3741\/products\/blue2_L_4dff8c95-2cbb-4c86-94cd-066fd499c7e9.jpg?v=1567190969"},{"product_id":"simplex-fiber-optic-cable-single-mode-os2-9125-corning-fiber-indoor-plenum-ofnp","title":"Simplex Fiber Optic Cable, Single Mode, OS2 9\/125, Corning Fiber, Indoor, Plenum OFNP","description":"\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0252\/1897\/3741\/files\/Made_In_USA.png?2208\" alt=\"Made in USA\" width=\"115px\" height=\"65px\" style=\"background-color: #fff; border-radius: 10px; padding: 5px;\"\u003e \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0252\/1897\/3741\/files\/UL_LISTED_LOGO_US.png?2209\" alt=\"UL Listed\" width=\"75px\" height=\"65px\" style=\"background-color: #fff; border-radius: 10px; padding: 5px;\"\u003e \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0252\/1897\/3741\/files\/Bullets-_RoHS.jpg?2209\" alt=\"RoHS Compliant\" width=\"55px\" height=\"75px\" style=\"background-color: #fff; border-radius: 10px; padding: 5px;\"\u003e \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0252\/1897\/3741\/files\/Bullets_PlusCorning.jpg?2209\" alt=\"Made with Corning Glass\" width=\"170px\" height=\"65px\" style=\"background-color: #fff; border-radius: 10px; padding: 5px;\"\u003e \u003cbr\u003e\u003cmeta charset=\"utf-8\"\u003e\u003c\/p\u003e\n\u003ch5\u003e\n\u003cb\u003eNote:\u003c\/b\u003e To request a quote email us or give us a call.\u003c\/h5\u003e\n\u003ch5\u003eIf you would like to inquire about our custom fiber cable options such as longer lengths, custom cut lengths, terminated ends, or pulleyes please call or email us.\u003c\/h5\u003e\n\u003ch4\u003eDescription\u003c\/h4\u003e\n\u003ch3\u003e\u003c\/h3\u003e\n\u003ch2\u003eSimplex CMP OS2 Singlemode Cable\u003c\/h2\u003e\n\u003cp\u003eSimplex Plenum OS2 Single Mode 9\/125 Fiber Cable is composed of a tight buffer, aramid yarn, and a PVC outer jacket. All component materials meet the EU RoHS and REACH Directive standards.\u003c\/p\u003e\n\u003cp\u003eThese plenum simplex fiber cables are available in 12 TIA standard colors or special order colors. The fiber cable is UL Listed OFNP for use in ducts, plenums and air-handling spaces. Standard surface print denotes construction, NEC rating, and fiber type, and includes footage markers. Available outer diameter sizes inculde 3 mm, 2 mm, 1.8 mm and 1.6 mm.\u003c\/p\u003e\n\u003cp\u003e\u003cmeta charset=\"utf-8\"\u003e\u003cspan\u003eCleaning your fiber connector end faces and components regularly is crucial for avoiding a total network failure. Ensure your optical fiber system is working properly and prevent major network issues with \u003c\/span\u003e\u003ca alt=\"Fiber Cleaning Kits\" href=\"https:\/\/www.primuscable.com\/collections\/fiber-cleaning-kit\" target=\"_blank\"\u003e\u003cstrong\u003efiber cleaning kits,\u003c\/strong\u003e\u003c\/a\u003e\u003cspan\u003e \u003c\/span\u003e\u003ca alt=\"Fiber Cleaning Pens\" href=\"https:\/\/www.primuscable.com\/collections\/fiber-cleaning-pens\" target=\"_blank\"\u003e\u003cstrong\u003epens,\u003c\/strong\u003e\u003c\/a\u003e\u003ca alt=\"Fiber Cleaning Fluids\" href=\"https:\/\/www.primuscable.com\/collections\/fiber-cleaning-fluids\" target=\"_blank\"\u003e\u003cstrong\u003e\u003cspan\u003e \u003c\/span\u003efluids,\u003c\/strong\u003e\u003c\/a\u003e\u003cspan\u003e and \u003c\/span\u003e\u003ca alt=\"Fiber Cleaning Wipes\" href=\"https:\/\/www.primuscable.com\/collections\/fiber-cleaning-wipes\" target=\"_blank\"\u003e\u003cstrong\u003ewipes.\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003ch4\u003eFeatures\u003c\/h4\u003e\n\u003ch3\u003e\u003cspan style=\"text-decoration: underline;\"\u003eFeatures\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e3 mm, 2 mm, 1.8 mm \u0026amp; 1.6 mm OD sizes to meet all patch cord applications.\u003c\/li\u003e\n\u003cli\u003eConsistent 3.5lbs - 5lbs pull force for easy strip-ability.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eApplications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003ePatch cord production.\u003c\/li\u003e\n\u003cli\u003eData centers.\u003c\/li\u003e\n\u003cli\u003eIndoor point to point connections.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eSpecifications\u003c\/h4\u003e\n\u003ch3\u003e\u003c\/h3\u003e\n\u003ctable width=\"100%\" class=\"table table-bordered text-center\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth colspan=\"2\"\u003eTECHNICAL SPECIFICATIONS\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth class=\"table-active\" scope=\"row\"\u003eTEMPERATURE RANGE\u003c\/th\u003e\n\u003ctd\u003eSTORAGE TEMPERATURE: -40ºC TO +70ºC\u003cbr\u003eOPERATING TEMPERATURE: -20ºC TO +70ºC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth class=\"table-active\" scope=\"row\"\u003eCABLE CHARACTERISTICS\u003c\/th\u003e\n\u003ctd\u003eFIBER COUNT: 1\u003cbr\u003eOUTER JACKET MATERIAL: FLAME RETARDANT PVC\u003cbr\u003eOUTER JACKET COLOR: YELLOW\u003cbr\u003eSTRENGTH MEMBER: ARAMID YARN\u003cbr\u003eTIGHT BUFFER MATERIAL: FLAME RETARDANT PVC\u003cbr\u003eTIGHT BUFFER COLOR: WHITE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth class=\"table-active\" scope=\"row\"\u003eMECHANICAL CHARACTERISTICS\u003c\/th\u003e\n\u003ctd\u003eNOMINAL OUTER DIAMETER: 3 MM \/ 2 MM \/ 1.80 MM \/ 1.60 MM\u003cbr\u003eMINIMUM BEND RADIUS (BEND INSENSITIVE SM): 5 MM \/ 10 MM\u003cbr\u003eMINIMUM BEND RADIUS (SM) 1 TURN \/ 100 TURNS: 32 MM \/ 50 MM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth class=\"table-active\" scope=\"row\"\u003eOPTICAL CHARACTERISTICS\u003c\/th\u003e\n\u003ctd\u003eCORE SIZE: 9 UM\u003cbr\u003eWAVELENGTH: (1310 \/ 1550) NM\u003cbr\u003eMAX. ATTENUATION: (0.5 \/ 0.4) DB\/KM\u003cbr\u003eBANDWIDTH (EMB) (HIGH PERFORMANCE): N\/A\u003cbr\u003eLINK LENGTH (10GB\/S): N\/A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4\u003eAdditional Information\u003c\/h4\u003e\n\u003ch3\u003e\u003c\/h3\u003e\n\u003ch3\u003e(We do not offer credits or returns for this item.)\u003cbr\u003eMinimum and Maximum Order Lengths for Non-Freight Shipments:\u003c\/h3\u003e\n\u003ctable width=\"100%\" border=\"1\" style=\"border: solid medium;\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: solid thin;\" bgcolor=\"#999999\"\u003e \u003c\/td\u003e\n\u003ctd style=\"border: solid thin;\" bgcolor=\"#FFE800\" align=\"center\"\u003e\u003cb\u003e3.0mm\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"border: solid thin;\" bgcolor=\"#FFE800\" align=\"center\"\u003e\u003cb\u003e2.0mm\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"border: solid thin;\" bgcolor=\"#FFE800\" align=\"center\"\u003e\u003cb\u003e1.6mm\u003c\/b\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: solid thin;\" bgcolor=\"#FF6F00\" align=\"center\"\u003e\u003cb\u003eMin.\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"border: solid thin;\" align=\"center\"\u003e1,000ft. (304m)\u003c\/td\u003e\n\u003ctd style=\"border: solid thin;\" align=\"center\"\u003e3,500ft. (1067m)\u003c\/td\u003e\n\u003ctd style=\"border: solid thin;\" align=\"center\"\u003e3,250ft. (991m)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: solid thin;\" bgcolor=\"#FF6F00\" align=\"center\"\u003e\u003cb\u003eMax.\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"border: solid thin;\" align=\"center\"\u003e13,000ft. (3962m)\u003c\/td\u003e\n\u003ctd style=\"border: solid thin;\" align=\"center\"\u003e16,900ft. (4876m)\u003c\/td\u003e\n\u003ctd style=\"border: solid thin;\" align=\"center\"\u003e16,000ft. (4876m)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eSingle mode fiber cable (Synonyms mono-mode optical fiber, single-mode fiber, single-mode optical waveguide, uni-mode fiber) is a single strand of glass fiber with a diameter of 8.3 to 10 microns that has one mode of transmission. Single mode fiber has a relatively narrow diameter, through which only one mode will propagate typically 1310 or 1550nm wavelengths. Single mode fibers carry higher bandwidth than multimode fiber, but require a light source with a narrow spectral width. Single-mode fiber gives you a higher transmission rate and up to 50 times more distance than multimode. The small core and single light-wave virtually eliminate any distortion that could result from overlapping light pulses, providing the least signal attenuation and the highest transmission speeds of any fiber cable type.\u003c\/p\u003e\n\u003ch4\u003eWhat's in the Box\u003c\/h4\u003e\n\u003ch3\u003e\n\u003cspan style=\"text-decoration: underline;\"\u003eWhat’s in the Box\u003c\/span\u003e\u003cbr\u003e\n\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eQty 1 - Simplex Fiber Optic Cable, Single Mode, OS2 9\/125, Corning Fiber, Indoor, Plenum OFNP\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Primus Cable","offers":[{"title":"3.0 mm","offer_id":31452638478397,"sku":"FB31-3819-SS3P","price":0.19,"currency_code":"USD","in_stock":true},{"title":"2.0 mm","offer_id":31452638511165,"sku":"FB31-3661-SS2P","price":0.19,"currency_code":"USD","in_stock":true},{"title":"1.8 mm","offer_id":31452638543933,"sku":"FB31-3583-SS18P","price":0.19,"currency_code":"USD","in_stock":true},{"title":"1.6 mm","offer_id":31452638576701,"sku":"FB31-1465-SS16P","price":0.19,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0252\/1897\/3741\/products\/Simplex-SM.jpg?v=1567191017"},{"product_id":"simplex-fiber-optic-cable-multimode-50125-10-gig-om3-corning-fiber-indoor-plenum-ofnp","title":"Simplex Plenum Fiber Optic Cable, Multimode 10 Gig OM3, Corning Fiber, Indoor","description":"\u003cp\u003e\u003cimg style=\"background-color: #fff; border-radius: 10px; padding: 5px;\" height=\"65px\" width=\"115px\" alt=\"Made in USA\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0252\/1897\/3741\/files\/Made_In_USA.png?2208\"\u003e \u003cimg style=\"background-color: #fff; border-radius: 10px; padding: 5px;\" height=\"65px\" width=\"75px\" alt=\"UL Listed\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0252\/1897\/3741\/files\/UL_LISTED_LOGO_US.png?2209\"\u003e \u003cimg style=\"background-color: #fff; border-radius: 10px; padding: 5px;\" height=\"75px\" width=\"55px\" alt=\"RoHS Compliant\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0252\/1897\/3741\/files\/Bullets-_RoHS.jpg?2209\"\u003e \u003cimg style=\"background-color: #fff; border-radius: 10px; padding: 5px;\" height=\"65px\" width=\"170px\" alt=\"Made with Corning Glass\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0252\/1897\/3741\/files\/Bullets_PlusCorning.jpg?2209\"\u003e \u003cbr\u003e\u003cmeta charset=\"utf-8\"\u003e\u003c\/p\u003e\n\u003ch5\u003e\n\u003cb\u003eNote:\u003c\/b\u003e To request a quote email us or give us a call.\u003c\/h5\u003e\n\u003ch5\u003eIf you would like to inquire about our custom fiber cable options such as longer lengths, custom cut lengths, terminated ends, or pulleyes please call or email us.\u003c\/h5\u003e\n\u003ch4\u003eDescription\u003c\/h4\u003e\n\u003ch3\u003e\u003cbr\u003e\u003c\/h3\u003e\n\u003ch2\u003eSimplex Fiber Optic Cable, Multimode, 50\/125 10 Gig OM3, Corning Fiber, Indoor, Plenum OFNP\u003c\/h2\u003e\n\u003cp\u003eSimplex Plenum OM3 MultiMode 50\/125 Fiber Cable is composed of a tight buffer, aramid yarn, and a PVC outer jacket. All component materials meet the EU RoHS and REACH Directive standards.\u003c\/p\u003e\n\u003cp\u003eThese plenum simplex fiber cables are available in 12 TIA standard colors or special order colors. The fiber cable is UL Listed OFNP for use in ducts, plenums and air-handling spaces. Standard surface print denotes construction, NEC rating, and fiber type, and includes footage markers. Available outer diameter sizes inculde 3 mm, 2 mm, 1.8 mm and 1.6 mm.\u003c\/p\u003e\n\u003cp\u003e\u003cmeta charset=\"utf-8\"\u003e\u003cspan\u003eCleaning your fiber connector end faces and components regularly is crucial for avoiding a total network failure. Ensure your optical fiber system is working properly and prevent major network issues with \u003c\/span\u003e\u003ca alt=\"Fiber Cleaning Kits\" href=\"https:\/\/www.primuscable.com\/collections\/fiber-cleaning-kit\" target=\"_blank\"\u003efiber cleaning kits,\u003c\/a\u003e \u003ca alt=\"Fiber Cleaning Pens\" href=\"https:\/\/www.primuscable.com\/collections\/fiber-cleaning-pens\" target=\"_blank\"\u003epens,\u003c\/a\u003e\u003ca alt=\"Fiber Cleaning Fluids\" href=\"https:\/\/www.primuscable.com\/collections\/fiber-cleaning-fluids\" target=\"_blank\"\u003e fluids,\u003c\/a\u003e and \u003ca alt=\"Fiber Cleaning Wipes\" href=\"https:\/\/www.primuscable.com\/collections\/fiber-cleaning-wipes\" target=\"_blank\"\u003ewipes.\u003c\/a\u003e\u003c\/p\u003e\n\u003ch4\u003eFeatures\u003c\/h4\u003e\n\u003ch3\u003e\u003cspan style=\"text-decoration: underline;\"\u003eFeatures\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e3 mm, 2 mm, 1.8 mm \u0026amp; 1.6 mm OD sizes to meet all patch cord applications.\u003c\/li\u003e\n\u003cli\u003eConsistent 3.5lbs - 5lbs pull force for easy strip-ability.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eApplications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003ePatch cord production.\u003c\/li\u003e\n\u003cli\u003eData centers.\u003c\/li\u003e\n\u003cli\u003eIndoor point to point connections.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eSpecifications\u003c\/h4\u003e\n\u003ch3\u003e\u003cbr\u003e\u003c\/h3\u003e\n\u003ctable width=\"100%\" class=\"table table-bordered text-center\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth colspan=\"2\"\u003eTECHNICAL SPECIFICATIONS\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003c!-- TEMPERATURE RANGE --\u003e\n\u003ctr\u003e\n\u003cth class=\"table-active\" colspan=\"2\"\u003eTEMPERATURE RANGE\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth class=\"table-active\" scope=\"row\"\u003eSTORAGE TEMPERATURE\u003c\/th\u003e\n\u003ctd\u003e-40ºC to +70ºC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth class=\"table-active\" scope=\"row\"\u003eOPERATING TEMPERATURE\u003c\/th\u003e\n\u003ctd\u003e-20ºC to +70ºC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c!-- CABLE CHARACTERISTICS --\u003e\n\u003ctr\u003e\n\u003cth class=\"table-active\" colspan=\"2\"\u003eCABLE CHARACTERISTICS\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth class=\"table-active\" scope=\"row\"\u003eFIBER COUNT\u003c\/th\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth class=\"table-active\" scope=\"row\"\u003eOUTER JACKET MATERIAL\u003c\/th\u003e\n\u003ctd\u003eFlame Retardant PVC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth class=\"table-active\" scope=\"row\"\u003eOUTER JACKET COLOR\u003c\/th\u003e\n\u003ctd\u003eAqua\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth class=\"table-active\" scope=\"row\"\u003eSTRENGTH MEMBER\u003c\/th\u003e\n\u003ctd\u003eAramid Yarn\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth class=\"table-active\" scope=\"row\"\u003eTIGHT BUFFER MATERIAL\u003c\/th\u003e\n\u003ctd\u003eFlame Retardant PVC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth class=\"table-active\" scope=\"row\"\u003eTIGHT BUFFER COLOR\u003c\/th\u003e\n\u003ctd\u003eWhite\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c!-- MECHANICAL CHARACTERISTICS --\u003e\n\u003ctr\u003e\n\u003cth class=\"table-active\" colspan=\"2\"\u003eMECHANICAL CHARACTERISTICS\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth class=\"table-active\" scope=\"row\"\u003eNOMINAL OUTER DIAMETER\u003c\/th\u003e\n\u003ctd\u003e3 mm \/ 2 mm \/ 1.80 mm \/ 1.60 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth class=\"table-active\" scope=\"row\"\u003eMINIMUM BEND RADIUS (BEND INSENSITIVE MM)\u003c\/th\u003e\n\u003ctd\u003e7.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c!-- OPTICAL CHARACTERISTICS --\u003e\n\u003ctr\u003e\n\u003cth class=\"table-active\" colspan=\"2\"\u003eOPTICAL CHARACTERISTICS\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth class=\"table-active\" scope=\"row\"\u003eCORE SIZE\u003c\/th\u003e\n\u003ctd\u003e50 um\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth class=\"table-active\" scope=\"row\"\u003eWAVELENGTH\u003c\/th\u003e\n\u003ctd\u003e(850 \/ 1300) nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth class=\"table-active\" scope=\"row\"\u003eMAX. ATTENUATION\u003c\/th\u003e\n\u003ctd\u003e(3.5 \/ 1.5) dB\/km\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth class=\"table-active\" scope=\"row\"\u003eBANDWIDTH (EMB) (HIGH PERFORMANCE)\u003c\/th\u003e\n\u003ctd\u003e2000 MHz @850nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth class=\"table-active\" scope=\"row\"\u003eLINK LENGTH (10GB\/S)\u003c\/th\u003e\n\u003ctd\u003e150 Meters\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4\u003eAdditional Information\u003c\/h4\u003e\n\u003ch3\u003e\u003cbr\u003e\u003c\/h3\u003e\n\u003ch3\u003e(We do not offer credits or returns for this item.)\u003cbr\u003eMinimum and Maximum Order Lengths for Non-Freight Shipments:\u003c\/h3\u003e\n\u003ctable class=\"table table-bordered text-center\" style=\"border: solid medium;\" border=\"1px\" width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd bgcolor=\"#999999\" style=\"border: solid thin;\"\u003e \u003c\/td\u003e\n\u003ctd align=\"center\" style=\"border: solid thin;\"\u003e\u003cb\u003e3.0mm\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" style=\"border: solid thin;\"\u003e\u003cb\u003e2.0mm\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" style=\"border: solid thin;\"\u003e\u003cb\u003e1.6mm\u003c\/b\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"center\" bgcolor=\"#FF6F00\" style=\"border: solid thin;\"\u003e\u003cb\u003eMin.\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" style=\"border: solid thin;\"\u003e1,000ft. (304m)\u003c\/td\u003e\n\u003ctd align=\"center\" style=\"border: solid thin;\"\u003e3,500ft. (1067m)\u003c\/td\u003e\n\u003ctd align=\"center\" style=\"border: solid thin;\"\u003e3,250ft. (991m)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"center\" bgcolor=\"#FF6F00\" style=\"border: solid thin;\"\u003e\u003cb\u003eMax.\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" style=\"border: solid thin;\"\u003e13,000ft. (3962m)\u003c\/td\u003e\n\u003ctd align=\"center\" style=\"border: solid thin;\"\u003e16,900ft. (4876m)\u003c\/td\u003e\n\u003ctd align=\"center\" style=\"border: solid thin;\"\u003e16,000ft. (4876m)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eMulti-Mode cable commonly has a diameter in the 50-to-100 micron range (typical multimode fiber core diameters are 50 or 62.5 micrometers). Multimode fiber gives you high bandwidth at high speeds (10 to 100MBS - Gigabit to 275m to 2km) over medium distances. Light waves are dispersed into numerous paths, or modes, as they travel through the cable's core typically 850 or 1300nm. However, in long cable runs (greater than 3000 feet [914.4 meters), multiple paths of light can cause signal distortion at the receiving end, resulting in an unclear and incomplete data transmission so designers now call for single mode fiber in new applications using Gigabit and beyond.\u003c\/p\u003e\n\u003ch4\u003eWhat's in the Box\u003c\/h4\u003e\n\u003ch3\u003e\u003cspan style=\"text-decoration: underline;\"\u003eWhat’s in the Box\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eQty 1 - Simplex Plenum Fiber Optic Cable, Multimode 10 Gig OM3, Corning Fiber, Indoor\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Primus Cable","offers":[{"title":"1.6 mm","offer_id":31453009281085,"sku":"FB31-1467-MS16P","price":0.17,"currency_code":"USD","in_stock":true},{"title":"1.8 mm","offer_id":31453009248317,"sku":"FB31-####-MS18P","price":0.2,"currency_code":"USD","in_stock":true},{"title":"2.0 mm","offer_id":31453009215549,"sku":"FB31-3831-MS2P","price":0.17,"currency_code":"USD","in_stock":true},{"title":"3.0 mm","offer_id":31453009182781,"sku":"FB31-3822-MS3P","price":0.18,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0252\/1897\/3741\/products\/Simplex-10G_3a5802f0-162c-4b44-9f1a-31c15ccd867b.png?v=1567191020"}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0252\/1897\/3741\/collections\/PC_Distribution-Fiber-Cable-CollBanner_a0068463-a4e8-459c-a412-9ceab96d667c.jpg?v=1782925768","url":"https:\/\/www.primuscable.com\/collections\/tight-buffer-fiber-cable.oembed?page=2","provider":"Primus Cable","version":"1.0","type":"link"}