{"product_id":"1000-shielded-plenum-fplp-red-fire-alarm-cable-16-2-solid-copper","title":"Fire Alarm Cable - FPLP - Shielded Plenum, 16\/2 AWG Solid Bare Copper Conductors, Red PVC Jacket, 1000 Feet","description":"\u003cp\u003e\u003cimg class=\"bulleticons\" height=\"65px\" width=\"115px\" alt=\"Made in USA\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0252\/1897\/3741\/files\/Made_In_USA.png?2208\"\u003e \u003cimg class=\"bulleticons\" height=\"75px\" width=\"55px\" alt=\"RoHS Compliant\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0252\/1897\/3741\/files\/Bullets-_RoHS.jpg?2209\"\u003e \u003cimg class=\"bulleticons\" height=\"68px\" width=\"68px\" alt=\"ETL Verified logo\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0252\/1897\/3741\/files\/Bullets-_ETL.jpg?2707\"\u003e\u003c\/p\u003e\n\u003ch4\u003eDescription\u003c\/h4\u003e\n\u003ch3\u003e\u003c\/h3\u003e\n\u003ch2\u003eFPLP Alarm Cable for Smoke Detectors and Voice Communications\u003c\/h2\u003e\n\u003cp\u003eThe Shielded Plenum (FPLP) Fire Alarm Cable features two 16 gauge solid bare copper conductors including aluminum mylar shielding over the conductors. It is encased with a low smoke PVC red jacket and equipped with a 24 gauge drain wire. The shielding provides protection against unwanted system noise. Sequential footage markings on the jacket facilitate an efficient installation process, allowing you to easily monitor the remaining cable length.\u003c\/p\u003e\n\u003cp\u003eWhen it comes to safeguarding lives, investing in top-tier fire alarm cables is crucial. We, as a reputable industry name, exclusively provide high-quality products. The significance of fire alarm cables lies in their role during emergencies. In the event of a fire, these cables enable the fire alarm system to activate sprinklers and trigger smoke alarms, alerting people to evacuate the premises promptly. Choose a trusted source for your fire alarm cables to ensure the utmost reliability when lives are at stake.\u003c\/p\u003e\n\u003ch3\u003eFire Alarm Applications\u003c\/h3\u003e\n\u003cp\u003eThere are many uses for a fire alarm cable such as smoke alarms, smoke detectors, voice communications, microprocessor controlled systems, pull boxes (fire alarm signals), burglar alarms, and other low voltage applications. Fire alarm circuits control and power applications such as safety functions, elevator capture and shutdown, door release, and damper control.\u003c\/p\u003e\n\u003ch3\u003eFire Alarm Cable Products\u003c\/h3\u003e\n\u003cp\u003eWe offer a variety of shielded and unshielded Plenum, Non-Plenum and Riser fire alarm cables FPLP and FPLR, ranging from 18 AWG to 12 AWG solid bare copper conductors. These fire cables are flexible for easy installation. With our commitment to quality and dependability our cables are UL, ETL Listed and RoHS Compliant. Plenum rated fire cables means it can be run in the area between floors that is used as duct area or other air space. Plenum refers to the material used in the jacket of the cable burns less than non-plenum cables.\u003c\/p\u003e\n\u003cp\u003eThe Plenum (FPLP) Fire Alarm Cable has two 12 gauge solid bare copper conductors. This plenum FPLP fire alarm cable has a low smoke PVC jacket safe for installation through environmental airflow spaces. Sequential footage markings on the jacket help facilitate the installation process, as you always know how much cable is remaining.\u003c\/p\u003e\n\u003ch3\u003eWhy Plenum?\u003c\/h3\u003e\n\u003cp\u003eA plenum space is the open area above the drop ceiling or below the floor that is used for air circulation in buildings. This could be a problem if there is a fire. Using non-plenum cables in a plenum space can spread fire and toxic smoke throughout a building. Plenum cable uses a flame-retardant jacket that is made of special plastics to prevent the release of harmful smoke. Plenum cable is mostly used in commercial applications such as schools and hospital buildings that house a large population of people. It also is required in most multi-floor business buildings with large plenum space areas.\u003c\/p\u003e\n\u003ch4\u003eFeatures\u003c\/h4\u003e\n\u003ch3\u003e\u003cspan style=\"text-decoration: underline;\"\u003eFeatures\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eLow smoke generating FT6 plenum rated PVC jacket\u003c\/li\u003e\n\u003cli\u003eSequential footage markings on jacket\u003c\/li\u003e\n\u003cli\u003eAluminum mylar shielding\u003c\/li\u003e\n\u003cli\u003eUL Listed\u003c\/li\u003e\n\u003cli\u003eETL listed\u003c\/li\u003e\n\u003cli\u003eRoHS Compliant\u003c\/li\u003e\n\u003cli\u003eVoltage rating: 300V\u003c\/li\u003e\n\u003cli\u003e24 gauge drain wire\u003c\/li\u003e\n\u003cli\u003eTemperature rating: 75°C\u003c\/li\u003e\n\u003cli\u003eMade in USA\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eFire alarm wiring\u003c\/li\u003e\n\u003cli\u003eFire protection\u003c\/li\u003e\n\u003cli\u003eSignals\u003c\/li\u003e\n\u003cli\u003eMonitoring and detection systems\u003c\/li\u003e\n\u003cli\u003eAudio circuits\u003c\/li\u003e\n\u003cli\u003eNotifications circuits\u003c\/li\u003e\n\u003cli\u003eControl circuits\u003c\/li\u003e\n\u003cli\u003eInitiating circuits\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eConductor Insulation Colors\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eBlack\u003c\/li\u003e\n\u003cli\u003eRed\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch4\u003eSpecifications\u003c\/h4\u003e\n\u003ch3\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0252\/1897\/3741\/files\/FA4-2001-122.pdf?3316\" target=\"_blank\"\u003e \u003cbutton class=\"download-btn\"\u003eDownload Spec Sheet\u003c\/button\u003e \u003c\/a\u003e\u003c\/p\u003e\n\u003cdiv class=\"table-responsive\"\u003e\n\u003ctable class=\"table table-bordered table-striped text-center\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth colspan=\"2\"\u003ePhysical Construction\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd width=\"50%\"\u003e\u003cstrong\u003eInner Conductor\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSolid Bare Copper\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConductor Size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e16 AWG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInsulation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLow Smoke PVC\u003cbr\u003e(0.010 in.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNominal OD\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2C = 4.47 mm (0.176 in.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOuter Jacket Diameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e.381mm (0.015in.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eJacket\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLow Smoke PVC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eJacket Color\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eShielding\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAluminum with Mylar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"table-responsive\"\u003e\n\u003ctable class=\"table table-bordered table-striped text-center\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth colspan=\"2\"\u003eElectrical Characteristics\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd width=\"50%\"\u003e\u003cstrong\u003eTemperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e75℃\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVoltage Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e300 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eColor Mode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBlack\u003cbr\u003eRed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003ch4\u003eAdditional Information\u003c\/h4\u003e\n\u003ch3\u003e\u003c\/h3\u003e\n\u003cp\u003eTo learn more about our Fire Alarm Bulk Cable here is a link to a page containing more information on our premium \u003ca href=\"\/info\/fire-alarm.aspx\" target=\"_blank\"\u003eFire Alarm Bulk Cable\u003c\/a\u003e.\u003c\/p\u003e\n\u003cp\u003eTo learn more about our CMP Rated Cable here is a link to a page containing more information on our premium \u003ca href=\"\/info\/plenum-cable.aspx\" target=\"_blank\"\u003eCMP Rated Cable\u003c\/a\u003e.\u003c\/p\u003e\n\u003ch4\u003eWhat's in the Box\u003c\/h4\u003e\n\u003ch3\u003e\u003cspan style=\"text-decoration: underline;\"\u003eWhat's in the Box\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eQty 1 - FPLP Fire Alarm Cable Plenum Shielded, 16\/2 AWG Solid Bare Copper Conductors, Red PVC Jacket (1000 Ft)\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Primus Cable","offers":[{"title":"Default Title","offer_id":30717851238445,"sku":"FA4-1997\/162","price":343.86,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0252\/1897\/3741\/products\/FA4-1995-182_01_15f58bc9-5bbd-4f15-a3a6-fc824de48ce2.jpg?v=1581530401","url":"https:\/\/www.primuscable.com\/products\/1000-shielded-plenum-fplp-red-fire-alarm-cable-16-2-solid-copper","provider":"Primus Cable","version":"1.0","type":"link"}