Smart Tracker Rack Mount NEMA Rated PDU, 60Hz

$1,100.00
SKU: NPNB-018-041-11
Color: Black
Various lead times may apply to this product. Please contact us for more details.

Descriptions

Smart Tracker Rack Mount NEMA Rated PDU

The Smart Tracker is an IP-ready, GPS-enabled device that provides the system owning and/or managing agency with remote access control of (8) NEMA Rated 5-15R outlets, (8) 10A output relays, (8) digital inputs, (2) analog DC voltage inputs (for battery voltage monitoring), plus temperature and humidity sensors – all in one unit!

Embedded in each Smart Tracker is a web page that provides a summary of system details and operating states. The web page allows the user to configure all outlets, relays, inputs, and other system parameters. This control is available anywhere with access to a standard web browser – saving time and money! While it is ideal in the field, the Smart Tracker has also proven valuable in other settings such as test laboratories, traffic control centers, server rooms, equipment hubs, and remote locations.

The three basic functions of the Smart Tracker are control, respond and automate.

Control - Outlets and Relays

While working against nature, power products face freezing temperatures, heat, and humidity. If high or low temperature and/or humidity thresholds are exceeded in the field, the agency will be notified automatically through an email or an SNMP trap of the event. The user may then enable power through outlets and/or relays to auxiliary fan kits or battery heater mats in order to maintain the functionality and efficiency of their cabinet.

Respond - Unpredictable & External Events

Utilizing the Smart Tracker, the user can effectively respond to unexpected events that occur on the power line. In the event of a brownout, the Smart Tracker will remotely indicate that the timer relay on the power supply has been exceeded and that the intersection may now be in flash mode. Once this occurs, the runtime is limited and a technician should report to the site to apply a generator to the system before power to the device is lost.

Automate – Tasks

A cabinet’s network switch, modem, or radio communication device may be plugged into outlet one and renamed “Communication Device”. Once the Smart Tracker has been set up for the cabinet’s network switch and is configured to be reset by pinging, an automated feature. It will then reset an outlet when network communication is lost. Ping can automatically restore network communication to the Smart Tracker if a network switch or network device has become unresponsive. A simple power reset may resolve the issue

Features

Features

  • Remotely command AC/DC power devices to cycle on or off
  • Alarm notifications alert traffic controllers
  • Control your equipment with the advanced scheduling feature
  • Digital inputs indicate when external events have occurred,
  • Fits standard 1RU 19"

Specifications

Specifications

HARDWARE SPECIFICATIONS

Remote Updates

Firmware and Unit Configuration

No. Outlets

8 Individually Controlled Outlets

LCD

Dual Line 2x20 Backlit

System Clock

NEMA 5-15R, 15A/125 VAC, 60Hz

Embedded Webpage

Password Protected User Interface

User Input

Pushbutton for Specific Actions

Event Log

Stores Thousands of Events

Automation

Scheduled Events and Actions

LEDs

Indicators for Active Outlets, Relays, and Digital Inputs

Relay & Input Connections

Screw Terminal Plugs for 12-22AWG Wire

Dimensions

1.7”H x 7.0”D x 19”W (43mm x 482mm x 178mm)

Weight

5lbs (2.26Kg)

Color

Black/Blue

Mounting

1RU Rack Mounting w/ Adjustable Rack Mount Brackets or Shelf Mount

DIGITAL INPUT SPECIFICATION

No. Digital Inputs

8 Individual Inputs (2 Contacts per Input)

Temperature Sensor

Embedded

Digital Input Voltage

5VDC, 10mA Max., Opto-Isolated Inputs

Humidity Sensor

Embedded

Analog Voltage(DC) Input

2 Independent DC Measurement Inputs

Analog Input Voltage (DC)

0-60VDC

OUTPUT RELAY SPECIFICATIONS

No. Output Relays

8 Individual Out Relays

Relay Switching Voltage

250VAC, 125VDC MAX

Relay Current Capacity

10 Amps, Each

AC INPUT SPECIFICATIONS

Voltage Range

85-154VAC;120VAC Nominal

Power Cord

Pluggable 5-15P, C13 15A/125VAC

Frequency

60Hz  ±3Hz

Circuit Breaker Rating

15A

Current Capacity

15A

ENVIRONMENTAL SPECIFICATION

Operating Temperature

-37°C to +74°C (-34°F to 165°F)

Operating Humidity

5-95% Non-condensing

Storage Temperature

-45°C to 85°C (-49°F to 185°F)

COMMUNICATION SPECIFICATIONS

Network Interface

10/100/1000 BASE-T Ethernet Port, RJ45 Connection, Auto MDI-x

Network Protocols

NTCIP/TCP/IP/HTTP/SNMP/SNTP/UDP

IP Addressing

DCHP and Static IP Addressing

Notification Type

SNMP Traps/Email Notification

SAFETY STANDARD SPECIFICATIONS

Standards

NEMA TS2-2016 v03.07

What's in the Box?

What's in the Box?

  • Qty 1 - Smart Tracker Rack Mount NEMA Rated PDU, 60Hz